The GESTRA BK 212 is a Duo steam trap built for very high steam pressures and temperatures. It is thermostatic and thermodynamic, with a corrosion-resistant Thermovit regulator made of stainless Duo plates that withstand water hammer. The datasheet covers the standard GESTRA BK 212 and the variants BK 212-S, BK 212-F91, BK 212-F91-SD, BK 212-F92-SD and BK 212-ASME, all in DN 15, 20 and 25.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list the BK 212 for buyers who need an exact GESTRA type for a repair, a replacement or a new project and want a clear technical summary before they ask for a quotation. Everything below is condensed from the manufacturer datasheet, so you can compare the BK 212 with the line conditions on your own drawings. Where a value is not stated in the datasheet, we leave it out rather than guess.

GESTRA equipment is common on steam and condensate systems, boiler houses and process plants, and many installed units in Omani and Gulf facilities are now several years old. That is why buyers often search by the exact type designation such as BK 212. Matching the designation, nominal size, pressure rating and connection type is the surest way to get the right replacement, and our team can help check these details against the nameplate or the earlier project documentation before a quotation is issued.

Key features of the BK 212

The datasheet describes the following points about the BK 212. They explain why this very high pressure steam trap is chosen for its duty and what to look for when comparing it with other options.

  • Thermovit regulator in corrosion-resistant Duo stainless steel.
  • Nozzle stem and seat in a wear-resistant titanium alloy.
  • Internal strainer and integral non-return valve action.
  • Asbestos-free graphite and CrNi body gasket.
  • Opens again at the adjusted opening temperature, discharging condensate at a given undercooling.
  • Installation in any position, and thermal air venting is possible.

Technical specifications of the BK 212

The table below summarises the main data for the BK 212 taken from the manufacturer datasheet. Always confirm the final pressure and temperature limits against the datasheet for the exact version and connection you plan to order, because ratings depend on connection type and size.

Parameter Value
Nominal sizes DN 15, 20, 25
Maximum differential pressure PMX 275 bar (3625 psi in the ASME table)
BK 212 body and cover 1.7383, PMA 630 bar g at 20 C, TMA up to 540 C at the lower pressure shown
BK 212-S body 1.7383, screws 1.4923, TMA up to 580 C
BK 212-F91 body 1.4903 (F91), PMA 775 bar g at 20 C
BK 212-F91-SD screws 2.4952, TMA up to 625 C
BK 212-F92-SD body 1.4901, PMA 800 bar g at 20 C, TMA up to 650 C
BK 212-ASME body ASTM A182 F22, screws A193 B16, PMA 430 bar g (6250 psi g) at 20 C
Design basis DIN EN 12516-2, ASME B16.34 for the ASME version
Note from datasheet Selected end connections may reduce the pressure and temperature ratings

Typical applications in Oman and the GCC

The BK 212 is a very high pressure steam trap, and the following use cases show where a unit of this kind is typically applied across oil and gas, utilities, water and manufacturing in Oman and the wider GCC. They are examples based on the described function and not a guarantee of suitability, so the actual operating data should always be checked.

  • Main steam and reheat line drains at power stations are the classic use for very high pressure traps, and the F91 and F92 versions are listed for the highest temperatures.
  • Refineries and petrochemical units with high-pressure steam headers use the same trap on turbine and header drains.
  • Large industrial boiler plants in the GCC that run superheated steam can use the variant whose temperature limit matches the line.

Selection and compatibility notes

Selecting the BK 212 correctly starts with the process data. Collect the operating pressure, the maximum and minimum temperature, the fluid, the flowrate and the connection standard of the existing pipework, then compare them with the datasheet. The notes below summarise the main decision points for this model.

  • Choose the variant by body material and temperature: BK 212 for standard service, BK 212-S for higher temperatures, F91 and F92 versions for the highest temperature and pressure limits.
  • Use the BK 212-ASME where the project specification requires an ASME B16.34 rated body in A182 F22.
  • Because end connections can reduce the ratings, confirm the connection type before finalising the specification.

Installation and commissioning of the BK 212

Before installing the BK 212, flush the line to remove weld spatter, scale and construction debris, because even a robust very high pressure steam trap can be damaged or held open by foreign particles. Check that the flow direction arrow or the marked inlet on the BK 212 matches the piping, and confirm that the nameplate type, size and pressure rating agree with the purchase documents.

Support the pipework so that no piping stress is transferred to the body of the BK 212. Use new gaskets of a type suitable for the fluid and temperature, tighten flange or union bolts evenly and in a cross pattern, and follow the instructions in the manufacturer installation and operating manual for the exact model. If the equipment is used in a potentially explosive area, the plant operator remains responsible for zoning and for preventing static charge, as the datasheet explains for GESTRA equipment.

During commissioning, bring the system up gradually. Open isolation valves slowly, vent trapped air where the design allows, and observe the BK 212 during the first warm-up for leaks at joints and for unusual noise or vibration. Record the first operating pressure and temperature so that later inspections have a reference.

Maintenance and service

The Duo plate stack is the control element and its deflection sets the opening temperature, so service work focuses on the regulator and the strainer.

Weld-in or socket-weld versions need isolation and cooling before any work.

A short routine inspection plan helps the BK 212 last longer. Note the date of installation, the service conditions and any events such as water hammer or overpressure. At each planned shutdown, inspect the visible joints, check for external corrosion or leakage and compare performance against the commissioning record. Only use spare parts and gaskets that suit the exact type and rating of the BK 212, and isolate and depressurise the line fully before any work is started.

Related products and ordering notes

Orders for the BK 212 should state the type designation, nominal size, pressure rating, end connection standard, material or version and the quantity required. If you are replacing an existing unit, add the nameplate data and a photograph of the nameplate when possible. The manufacturer family also includes other steam, condensate and flow control products, and we can quote related items together with the BK 212 when you send a combined enquiry. Seven Star LLC does not publish prices on this page, so each enquiry is answered with a written quotation.

Frequently asked questions

What is the maximum differential pressure? The datasheet states 275 bar for all listed variants, shown as 3625 psi for the ASME version.

Which variants are covered? BK 212, BK 212-S, BK 212-F91, BK 212-F91-SD, BK 212-F92-SD and BK 212-ASME.

Which sizes can I order? DN 15, 20 and 25. Please confirm against the manufacturer datasheet.

What material is the seat? Nozzle stem and seat are made of a wear-resistant titanium alloy.

Can end connections reduce the ratings? Yes. The datasheet warns that the selected end connections may reduce the pressure and temperature ratings.

Documents and quotation

The manufacturer datasheet for the BK 212 is attached to this page as a PDF so you can verify every value above and share it with your engineering team. To receive a quotation, send an RFQ that includes the part number BK 212, the nominal size, the pressure rating and connection type, and the quantity you need. Our team in Muscat will confirm availability and lead time and reply with a written offer for delivery to Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet GESTRA BK 212 Duo Steam Trap for Very High Pressure DN 15-25 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

GESTRA is the German steam and condensate specialist behind the UNA ball float steam traps, the MPA blowdown valves and a long line of boiler level and conductivity controls. It was founded in Bremen in 1902 by Gustav F. Gerdts, and has been part of Spirax Sarco since 2017.

Seven Star LLC is an independent supplier in Muscat. We list GESTRA steam traps, blowdown valves and boiler control equipment, and supply GESTRA parts and spares to boiler houses and process plants in Oman and the GCC.

GESTRA company profile

Established 29 October 1902, Bremen, Germany, by Gustav Friedrich Gerdts; renamed Gustav F. Gerdts KG in 1907
Ownership history Became a stock corporation (GESTRA AG) in 1987, was taken over by Flowserve in 2002, and has been part of the Spirax Sarco group since 2017
Product families Steam traps, non-return and check valves, boiler blowdown valves, control valves, and boiler control electronics for level, conductivity and temperature
Applications Steam boilers, steam distribution and condensate return in process plants, power stations, hospitals, food and textile plants

Milestones

  • 1902: Gustav Friedrich Gerdts founds the company in Bremen on 29 October.
  • 1907: The company is renamed Gustav F. Gerdts KG.
  • 1987: It becomes a stock corporation, GESTRA AG.
  • 2002: Flowserve takes over GESTRA.
  • 2017: GESTRA becomes part of the Spirax Sarco group.

GESTRA products we list

Series Type What it does
UNA 45, UNA 16, UNA 38 Ball float steam traps Continuous condensate discharge from heat exchangers and process equipment; the UNA 38 is the high-pressure version (PN 100)
BK 45 Bimetallic steam trap Robust trap for steam main drainage and tracing, resistant to water hammer
MK 45, TK 23, SMK 22-81 Thermostatic steam traps Air venting and condensate discharge; the SMK 22-81 is the sanitary version for clean steam
MPA 46 Rapid-action blowdown valve Short, intermittent bottom blowdown that removes sludge from the boiler
NRS 1-54, NRR 2-50, NRR 2-60, NRGT 26-2 Boiler level controls Water level limiting, feedwater control and continuous level measurement
LRGT 16-1, LRR 1-50 Conductivity measurement and control Keeps boiler water conductivity in range through continuous blowdown
TRS 5-50 Safety temperature limiter SIL 3 temperature limiting for boilers and hot water systems

The type of steam trap follows the duty. Ball float traps discharge condensate as soon as it forms, which suits heat exchangers with changing loads. Thermostatic and bimetallic traps hold condensate back slightly and suit steam mains, tracing and air venting. On the boiler itself, GESTRA level and conductivity electronics work as a system: electrodes or transmitters in the boiler, controllers in the panel, and the feedwater and blowdown valves they drive.

Where GESTRA products are used

In Oman and the GCC, GESTRA equipment is used in boiler houses of refineries, petrochemical and fertiliser plants, power and desalination stations, food and beverage plants, laundries, hotels and hospitals.

Ordering GESTRA parts: what we need

Send the type designation, pressure rating (PN) and connection size (DN), the end connection (flanged, screwed or socket weld), the operating pressure and condensate load for steam traps, and the supply voltage and bus type (CAN bus, 4-20 mA) for control equipment. For electrodes, add the insertion length.

Facts checked against GESTRA company history and Bremen city records, October 2026.

FAQ

Questions about the GESTRA BK 212 Duo Steam Trap for Very High Pressure

Answers from our engineering team on installation, compatibility and integration.

01What is the maximum differential pressure?
The datasheet states 275 bar for all listed variants, shown as 3625 psi for the ASME version.
02Which variants are covered?
BK 212, BK 212-S, BK 212-F91, BK 212-F91-SD, BK 212-F92-SD and BK 212-ASME.
03Which sizes can I order?
DN 15, 20 and 25. Please confirm against the manufacturer datasheet.
04What material is the seat?
Nozzle stem and seat are made of a wear-resistant titanium alloy.
05Can end connections reduce the ratings?
Yes. The datasheet warns that the selected end connections may reduce the pressure and temperature ratings.