GESTRA UNA 25-PK Pump Trap PN 40, DN 40 Condensate Lifter
Description
GESTRA UNA 25-PK Pump Trap PN 40 DN 40: overview
The GESTRA UNA 25-PK is a pump trap for steam condensate. It works as a steam trap when there is enough differential pressure and as a cyclic condensate lifter, driven by motive steam, when the upstream pressure is lower than the backpressure. That lets it remove condensate even where the steam pressure is too low for a conventional trap. It is supplied in PN 40, DN 40 and shares its datasheet with the simpler UNA 25-PS lifter.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list the GESTRA UNA 25-PK for buyers who need an exact GESTRA type for a repair, a replacement or a new project and want a clear technical summary before they ask for a quotation. Everything below is condensed from the manufacturer datasheet, so you can compare the UNA 25-PK with the line conditions on your own drawings. Where a value is not stated in the datasheet, we leave it out rather than guess.
GESTRA equipment is common on steam and condensate systems, boiler houses and process plants, and many installed units in Omani and Gulf facilities are now several years old. That is why buyers often search by the exact type designation such as UNA 25-PK. Matching the designation, nominal size, pressure rating and connection type is the surest way to get the right replacement, and our team can help check these details against the nameplate or the earlier project documentation before a quotation is issued.
Key features of the UNA 25-PK
The datasheet describes the following points about the UNA 25-PK. They explain why this pump trap is chosen for its duty and what to look for when comparing it with other options.
- Dual function: continuous trapping through a rolling ball valve closure, and pumping mode as a cyclic condensate lifter.
- Motive steam forces the condensate through an immersion tube out of the trap body.
- Gas-tight non-return valve at the inlet and a spring-loaded ball at the outlet prevent backflow.
- Works as a modulating steam trap if the differential pressure is sufficient.
- Two orifices, Orifice 6 and Orifice 13, to match the differential pressure.
- Float with valve control linkage that opens the motive steam inlet at the upper tripping point and closes the vent valve.
Technical specifications of the UNA 25-PK
The table below summarises the main data for the UNA 25-PK taken from the manufacturer datasheet. Always confirm the final pressure and temperature limits against the datasheet for the exact version and connection you plan to order, because ratings depend on connection type and size.
| Parameter | Value |
|---|---|
| Nominal size | DN 40 |
| Pressure rating | PN 40 (flange EN 1092-2), Class 150 option |
| Flange PN 40 limits | 25.0 bar at 350 C, with higher values at lower temperatures |
| Class 150 limits (ASME B16.5) | 6.6 bar at 350 C, with higher values at lower temperatures |
| Orifice 6 | KVS 3.5 m3/h, bore 11.0 mm |
| Orifice 13 | KVS 2.1 m3/h, bore 8.5 mm |
| Overall length (flanged / screwed) | 230 mm / 227 mm |
| Width / total height | 325 mm / 318 mm |
| Space required for servicing | 200 mm |
| Weight (flanged / screwed) | 31 kg / 26 kg |
Typical applications in Oman and the GCC
The UNA 25-PK is a pump trap, and the following use cases show where a unit of this kind is typically applied across oil and gas, utilities, water and manufacturing in Oman and the wider GCC. They are examples based on the described function and not a guarantee of suitability, so the actual operating data should always be checked.
- Heat exchangers on refinery and gas-processing units sometimes run at modulated steam pressure, and a pump trap prevents the condensate from backing up into the exchanger when the load is low.
- In utility and power plants in the GCC, the same unit can lift condensate from a low point back to a collection tank without an electric pump.
- In manufacturing, drying cylinders, platen presses and tank heating coils that run at varying steam pressure benefit from a unit that traps and pumps in one body.
Selection and compatibility notes
Selecting the UNA 25-PK correctly starts with the process data. Collect the operating pressure, the maximum and minimum temperature, the fluid, the flowrate and the connection standard of the existing pipework, then compare them with the datasheet. The notes below summarise the main decision points for this model.
- Pick Orifice 6 or Orifice 13 using the capacity charts in the datasheet, which show hot-condensate flowrates for trapping and pumping modes.
- Remember that the datasheet reduces differential pressure by about 1 bar for every 7 m of lift downstream of the trap.
- Use the UNA 25-PS where the unit must always work as a lifter, and the UNA 25-PK where it should also trap when pressure allows.
Installation and commissioning of the UNA 25-PK
Before installing the UNA 25-PK, flush the line to remove weld spatter, scale and construction debris, because even a robust pump trap can be damaged or held open by foreign particles. Check that the flow direction arrow or the marked inlet on the UNA 25-PK matches the piping, and confirm that the nameplate type, size and pressure rating agree with the purchase documents.
Support the pipework so that no piping stress is transferred to the body of the UNA 25-PK. Use new gaskets of a type suitable for the fluid and temperature, tighten flange or union bolts evenly and in a cross pattern, and follow the instructions in the manufacturer installation and operating manual for the exact model. If the equipment is used in a potentially explosive area, the plant operator remains responsible for zoning and for preventing static charge, as the datasheet explains for GESTRA equipment.
During commissioning, bring the system up gradually. Open isolation valves slowly, vent trapped air where the design allows, and observe the UNA 25-PK during the first warm-up for leaks at joints and for unusual noise or vibration. Record the first operating pressure and temperature so that later inspections have a reference.
Maintenance and service
Because the unit cycles with the float, check the valve control linkage, the vent valve and both non-return elements during planned shutdowns.
Allow the 200 mm servicing space shown in the datasheet when planning the installation.
A short routine inspection plan helps the UNA 25-PK last longer. Note the date of installation, the service conditions and any events such as water hammer or overpressure. At each planned shutdown, inspect the visible joints, check for external corrosion or leakage and compare performance against the commissioning record. Only use spare parts and gaskets that suit the exact type and rating of the UNA 25-PK, and isolate and depressurise the line fully before any work is started.
Related products and ordering notes
Orders for the UNA 25-PK should state the type designation, nominal size, pressure rating, end connection standard, material or version and the quantity required. If you are replacing an existing unit, add the nameplate data and a photograph of the nameplate when possible. The manufacturer family also includes other steam, condensate and flow control products, and we can quote related items together with the UNA 25-PK when you send a combined enquiry. Seven Star LLC does not publish prices on this page, so each enquiry is answered with a written quotation.
Frequently asked questions
What is the difference between the UNA 25-PK and UNA 25-PS? The UNA 25-PS always works as a cyclic condensate lifter without valve closure, while the UNA 25-PK adds a rolling ball valve closure so it can also run as a leak-proof steam trap when differential pressure is enough.
Which size and rating does it come in? The datasheet lists DN 40 with PN 40 flanges, or screwed G and NPT sockets and Class 150 flanges.
What drives the pumping action? Motive steam. When the float reaches its upper tripping point the control linkage opens the motive steam inlet and closes the vent valve.
What orifices are offered? Orifice 6 has a KVS of 3.5 m3/h and an 11.0 mm bore. Orifice 13 has a KVS of 2.1 m3/h and an 8.5 mm bore.
What is the weight? The datasheet gives 31 kg for flanged versions and 26 kg for screwed-socket versions.
Documents and quotation
The manufacturer datasheet for the UNA 25-PK is attached to this page as a PDF so you can verify every value above and share it with your engineering team. To receive a quotation, send an RFQ that includes the part number UNA 25-PK, the nominal size, the pressure rating and connection type, and the quantity you need. Our team in Muscat will confirm availability and lead time and reply with a written offer for delivery to Oman and the GCC.
Datasheets & Documents
- Datasheet GESTRA UNA 25-PK Pump Trap PN 40, DN 40 Condensate Lifter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
GESTRA is the German steam and condensate specialist behind the UNA ball float steam traps, the MPA blowdown valves and a long line of boiler level and conductivity controls. It was founded in Bremen in 1902 by Gustav F. Gerdts, and has been part of Spirax Sarco since 2017.
Seven Star LLC is an independent supplier in Muscat. We list GESTRA steam traps, blowdown valves and boiler control equipment, and supply GESTRA parts and spares to boiler houses and process plants in Oman and the GCC.
GESTRA company profile
| Established | 29 October 1902, Bremen, Germany, by Gustav Friedrich Gerdts; renamed Gustav F. Gerdts KG in 1907 |
|---|---|
| Ownership history | Became a stock corporation (GESTRA AG) in 1987, was taken over by Flowserve in 2002, and has been part of the Spirax Sarco group since 2017 |
| Product families | Steam traps, non-return and check valves, boiler blowdown valves, control valves, and boiler control electronics for level, conductivity and temperature |
| Applications | Steam boilers, steam distribution and condensate return in process plants, power stations, hospitals, food and textile plants |
Milestones
- 1902: Gustav Friedrich Gerdts founds the company in Bremen on 29 October.
- 1907: The company is renamed Gustav F. Gerdts KG.
- 1987: It becomes a stock corporation, GESTRA AG.
- 2002: Flowserve takes over GESTRA.
- 2017: GESTRA becomes part of the Spirax Sarco group.
GESTRA products we list
| Series | Type | What it does |
|---|---|---|
| UNA 45, UNA 16, UNA 38 | Ball float steam traps | Continuous condensate discharge from heat exchangers and process equipment; the UNA 38 is the high-pressure version (PN 100) |
| BK 45 | Bimetallic steam trap | Robust trap for steam main drainage and tracing, resistant to water hammer |
| MK 45, TK 23, SMK 22-81 | Thermostatic steam traps | Air venting and condensate discharge; the SMK 22-81 is the sanitary version for clean steam |
| MPA 46 | Rapid-action blowdown valve | Short, intermittent bottom blowdown that removes sludge from the boiler |
| NRS 1-54, NRR 2-50, NRR 2-60, NRGT 26-2 | Boiler level controls | Water level limiting, feedwater control and continuous level measurement |
| LRGT 16-1, LRR 1-50 | Conductivity measurement and control | Keeps boiler water conductivity in range through continuous blowdown |
| TRS 5-50 | Safety temperature limiter | SIL 3 temperature limiting for boilers and hot water systems |
The type of steam trap follows the duty. Ball float traps discharge condensate as soon as it forms, which suits heat exchangers with changing loads. Thermostatic and bimetallic traps hold condensate back slightly and suit steam mains, tracing and air venting. On the boiler itself, GESTRA level and conductivity electronics work as a system: electrodes or transmitters in the boiler, controllers in the panel, and the feedwater and blowdown valves they drive.
Where GESTRA products are used
In Oman and the GCC, GESTRA equipment is used in boiler houses of refineries, petrochemical and fertiliser plants, power and desalination stations, food and beverage plants, laundries, hotels and hospitals.
Ordering GESTRA parts: what we need
Send the type designation, pressure rating (PN) and connection size (DN), the end connection (flanged, screwed or socket weld), the operating pressure and condensate load for steam traps, and the supply voltage and bus type (CAN bus, 4-20 mA) for control equipment. For electrodes, add the insertion length.
Facts checked against GESTRA company history and Bremen city records, October 2026.
Browse GESTRA products by category: Liquid Analysis Sensors.
FAQ
Questions about the GESTRA UNA 25-PK Pump Trap PN 40, DN 40 Condensate
Answers from our engineering team on installation, compatibility and integration.
01What is the difference between the UNA 25-PK and UNA 25-PS?
The UNA 25-PS always works as a cyclic condensate lifter without valve closure, while the UNA 25-PK adds a rolling ball valve closure so it can also run as a leak-proof steam trap when differential pressure is enough.
02Which size and rating does it come in?
The datasheet lists DN 40 with PN 40 flanges, or screwed G and NPT sockets and Class 150 flanges.
03What drives the pumping action?
Motive steam. When the float reaches its upper tripping point the control linkage opens the motive steam inlet and closes the vent valve.
04What orifices are offered?
Orifice 6 has a KVS of 3.5 m3/h and an 11.0 mm bore. Orifice 13 has a KVS of 2.1 m3/h and an 8.5 mm bore.
05What is the weight?
The datasheet gives 31 kg for flanged versions and 26 kg for screwed-socket versions.