- Automation & ControlView all 2,741 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- HMI Displays
- Servo Drives
- Pneumatic Cylinders
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: MICHELL Instruments
Michell PT-MON Promet EExd Process Moisture Analyzer Main Unit
Description
Michell PT-MON overview: flameproof process moisture analyzer main unit
Michell PT-MON is the parent order code of the Michell Promet EExd main unit, a flameproof moisture analyzer for critical process gas applications. The order-code sheet describes it as an EExd ceramic metal oxide moisture analyser with a range of minus 120 to plus 30 degrees Celsius dew point, from 1 ppbV to 30,000 ppmV.
It has mains power, a capacitive touch screen, integrated pressure reading and flow alarms, Modbus RTU, two 4-20 mA outputs and two volt-free contacts per channel. The datasheet describes single or dual channel measurement with moisture content, dew point and pressure in one field-installed housing.
Gas processors in the Gulf use the Promet family for natural gas glycol dehydration, offshore export pipelines, transmission monitoring and LNG production.
The image shows the Promet EExd analyzer from the manufacturer datasheet.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Michell PT-MON so that maintenance, instrumentation and procurement teams can quote the exact code that appears in the manufacturer documentation.
Key features of PT-MON
- Single or dual measurement channel with integrated electronic pressure reading in one flameproof housing.
- Range of minus 120 to plus 30 degrees Celsius dew point, 1 ppbV to 30,000 ppmV, with automatic pressure compensated conversions for natural gas and ideal gas.
- Dew-point accuracy of plus or minus 1 degree Celsius between minus 59.9 and plus 20 degrees; plus or minus 2 degrees from minus 60 to minus 100 degrees.
- Capacitive touch screen through glass, vacuum fluorescent display and a rolling datalog of 150 entries.
- Two non-isolated 4-20 mA outputs per channel, Modbus RTU and alarms, with a sample flow alarm as standard.
- Hazardous-area certificates listed: ATEX and UKCA II 2 G Ex db IIB+H2 Gb, IECEx, cQPSus and additional national approvals.
PT-MON technical specifications
The table below lists values published by the manufacturer for the product family of PT-MON. Where a value depends on the ordered configuration, the table says so and the order-code sheet governs.
| Parameter | Value |
|---|---|
| Order code (parent) | PT-MON, Promet EExd main unit |
| Channels | Single or two channel (order code) |
| Measurement range | Minus 120 to plus 30 degC dp; 1 ppbV to 30,000 ppmV; 0 to 250 barg |
| Calibration range | Minus 100 to plus 20 degC dp; 10 ppbV to 23,000 ppmV |
| Dew-point accuracy | Plus or minus 1 degC (minus 59.9 to plus 20 degC); plus or minus 2 degC (minus 60 to minus 100 degC) |
| Pressure accuracy | Plus or minus 0.25 percent of full scale |
| Outputs | Two 4-20 mA per channel; Modbus RTU 9600 baud; volt-free alarm contacts |
| Display | Vacuum fluorescent; capacitive touch interface |
| Operating pressure | 30 to 138 barg |
| Sample connection | 1/8 inch NPT female |
| Sample flow | 1 Nl/min (2.1 scfh) nominal; flow alarm standard |
| Enclosure | Flameproof EExd cast copper-free aluminium, black powder coat |
| Hazardous area (ATEX/UKCA) | II 2 G Ex db IIB+H2 Gb, T5 or T4 or T3 depending on ambient and pressure |
Typical applications of PT-MON in Oman and the GCC
- Natural gas glycol dehydration and molecular sieve outlet monitoring.
- Offshore export pipelines and transmission pipeline monitoring.
- LNG production and hydrogen production, storage and transport.
- Ethylene feedstock to polymer plants and speciality gases.
For operators in Oman and the GCC, process analyzers of this type are used where quality, safety or custody transfer depends on a defined gas composition: natural gas conditioning and export, glycol and molecular sieve dehydration units, LNG trains, refinery recycle gas, hydrogen and inert gas systems, and power generation fuel gas. Remote sites with high ambient temperatures need analyzers that are properly housed, certified for the area class, and supported with spares, which is why exact part numbers such as PT-MON matter.
Selection and compatibility notes
The PT-MON order string specifies channel count and pressure (A for one channel to 60 barg, B for one channel to 138 barg, C for two channels to 138 barg), hazardous-area configuration (ATEX and IECEx or North American), and the natural gas moisture calculation, IGT Bulletin 8 or ISO 18453. Material certificates PT-MON-M1 and PT-MON-M2 are ordered separately.
A complete analyzer with sampling system is a different parent code, PT-SYS-I or PT-SYS-M.
When selecting PT-MON, state the gas composition, operating pressure range, area classification, power supply and output requirements, and whether a sampling system is needed. Process analyzers are built to configuration, so we match your request to the manufacturer order-code sheet and confirm each option before quotation.
Installation and commissioning of PT-MON
Install within the pressure and temperature limits of the certificate, with a conditioned sample at about 1 Nl/min, and connect the cable entries using certified glands. The datasheet notes internal temperature control to protect against condensation.
Install the analyzer close to the sample point where practical, supply it with a conditioned, representative sample at the pressure and flow stated in the manufacturer documentation, and make cable and gas entries with fittings that match the hazardous-area certificate. Follow the manual for electrical connections, vent routing and the first power-up sequence, and have a competent person verify the installation against the local area-classification drawings before energising.
Maintenance, calibration and service
The manufacturer lists a water dew-point sensor assembly PTS-WDC with a service calibration exchange PTS-SX-WDC, coalescer and membrane filter kit PT-SFK, glycol adsorption cartridges PTS-GAC and filter element PTS-PFT as spares.
Routine care is mainly calibration verification, sample conditioning upkeep and replacement of consumable or wear items. Keep a record of calibration checks, alarms and any service performed, use the manufacturer recommended intervals as a starting point, and adjust them to your process experience and your site integrity procedures.
Related products and ordering notes for PT-MON
- PTS-WDC: water dew-point sensor assembly for the Promet.
- CD2-MON: Condumax II hydrocarbon and water dew-point analyzer.
- QMA601: quartz crystal microbalance moisture analyzer for trace moisture.
When you request PT-MON, tell us whether the item is for a new installation, a like-for-like replacement or a spares stock, because that changes which accessories and documents are worth adding to the same quotation. Our team can also check related codes from the same order-code sheet so that one RFQ covers the transmitter or analyzer, its consumables and its calibration needs.
Frequently asked questions about PT-MON
- What is PT-MON? PT-MON is the manufacturer parent code for the Promet EExd main unit, a flameproof single or dual channel process moisture analyzer.
- What does PT-MON suit? It suits moisture measurement in process gas, especially natural gas, in classified areas, over a range of minus 120 to plus 30 degrees Celsius dew point.
- Is a sampling system included with PT-MON? No. PT-MON is the main unit only; the manufacturer lists PT-SYS-I and PT-SYS-M as separate codes for the analyzer with a sampling system.
- What should I send with an RFQ for PT-MON? Send the part number PT-MON, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.
Documents and quotation
A manufacturer document is available for the product family of PT-MON and we can send it with your quotation where the family datasheet applies. To request pricing and lead time, send an RFQ to Seven Star LLC with the part number PT-MON, the quantity, the full configuration or host-instrument details, the delivery location and any certificate requirements such as material certificates or calibration documents. We will confirm availability and respond with a quotation for PT-MON in writing.
Datasheets & Documents
- Datasheet Michell PT-MON Promet EExd Process Moisture Analyzer Main Unit Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Michell Instruments is a British manufacturer of humidity and dew point instruments, founded in 1974 in Cambridge, England, by Andrew Michell and incorporated on 12 September 1974. It worked with Cambridge University scientists on an aluminium oxide dew point sensor and later developed chilled mirror hygrometers and hydrocarbon dew point analysers. Michell is based in Ely, Cambridgeshire, and is part of Process Sensing Technologies (PST).
Seven Star LLC lists Michell dew-point transmitters, the Condumax II analyzer and its replacement sensor parts, and supplies them to gas plants and compressed air users in Oman by exact order code.
MICHELL Instruments company profile
| Founded | 1974, Cambridge, England, by Andrew Michell |
|---|---|
| Headquarters | Ely, Cambridgeshire, United Kingdom, since 2007 |
| Ownership | Process Sensing Technologies (PST) |
| Technology | Ceramic and aluminium oxide moisture sensors, chilled mirror dew point, Condumax hydrocarbon dew point (licensed from Shell) |
| Product families | Easidew and Promet dew point transmitters, S8000 and Optidew chilled mirror hygrometers, Condumax II hydrocarbon dew point analysers, MDM300 portable dew point meters, oxygen analysers |
Milestones
- 1974: Andrew Michell founds Michell Instruments in Cambridge.
- 2007: The company moves to Ely, Cambridgeshire.
- 2024: Michell marks 50 years, now as part of PST.
Michell product families on this page
The Condumax II is an automatic hydrocarbon dew-point analyzer for natural gas. Several of its parts are listed separately: the CD2-SCR-002 hydrocarbon dew-point sensor cell, the CD2-WDC-002 water dew-point sensor assembly and the CD2-SX-WDC-002, which is the exchange version of that water dew-point sensor. The Easidew line is represented by the Easidew EA2 dew point transmitter and by the Easidew PRO I.S., an intrinsically safe moisture transmitter for hazardous areas. A ceramic impedance moisture sensor module is also listed, the sensing element behind these transmitters.
Where Michell analyzers are used
Hydrocarbon and water dew point are contract quality parameters for natural gas, so the Condumax II is found at gas processing plants, pipeline entry points and custody transfer stations. Easidew transmitters monitor dryers for instrument air and industrial gases, glove boxes, and dry gas feeds to processes that cannot tolerate water.
MICHELL Instruments products we list
Ordering Michell parts: what we need
For Condumax II parts send the analyzer serial number and the part code, such as CD2-SCR-002, and state if a new assembly or the exchange item is wanted. For Easidew transmitters we need the measuring span in dew point or ppm, the process connection thread, the output signal, the operating pressure, the gas and the area certification. A photo of the label on the old transmitter usually answers most of these in one go.
Facts checked against UK Companies House records and PST's Michell 50-year material, October 2026.
Browse MICHELL Instruments products by category: Gas Analyzer Accessories, Gas Analyzer Systems.
FAQ
Questions about the Michell PT-MON Promet EExd Process Moisture
Answers from our engineering team on installation, compatibility and integration.
01What is PT-MON?
PT-MON is the manufacturer parent code for the Promet EExd main unit, a flameproof single or dual channel process moisture analyzer.
02What does PT-MON suit?
It suits moisture measurement in process gas, especially natural gas, in classified areas, over a range of minus 120 to plus 30 degrees Celsius dew point.
03Is a sampling system included with PT-MON?
No. PT-MON is the main unit only; the manufacturer lists PT-SYS-I and PT-SYS-M as separate codes for the analyzer with a sampling system.
04Can Seven Star LLC supply PT-MON in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
05What should I send with an RFQ for PT-MON?
Send the part number PT-MON, the quantity, the full configuration or host instrument model and serial number, any certificate needs and the delivery location so we can prepare an accurate quotation. The manufacturer datasheet for the product family can accompany the quotation.


















Reviews
There are no reviews yet.