Servomex 2323-7928 Chemraz O-Ring for Oxy 1900 Inlet Filter

Description

Servomex 2323-7928 overview: Chemraz inlet filter O-ring for the Oxy 1900 digital analyser

The Servomex 2323-7928 is the Chemraz inlet filter O-ring for the 1900 Digital oxygen analyser. The manual lists it for an analyser with a solvent-resistant oxygen transducer. Chemraz is a perfluoroelastomer family chosen for aggressive vapours, which is why this part exists as a separate item from the Viton version.

The image on this page shows the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser) that this item belongs to, so that buyers can recognise the equipment family; it is not a close-up of the Chemraz inlet filter O-ring itself. Every detail on this page is taken from the manufacturer documentation for that equipment, and where a value is not stated there, we have left it out rather than guess.

Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We list Servomex 2323-7928 so that maintenance and procurement teams can quote the exact number that appears in the manufacturer manual, which matters because instrument spares are rarely interchangeable by description alone.

Key features of 2323-7928

  • Exact manufacturer part number 2323-7928, taken from the documented spares or parts list of the analyser.
  • Item: Chemraz inlet filter O-ring.
  • Intended equipment: SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser).
  • Use the 2323-7928 only on analysers fitted with the solvent-resistant transducer.
  • Supplied against a quotation request that confirms the analyser model, serial number and quantity.

Technical specifications for 2323-7928

The first table records the data for the part itself, as given in the manufacturer documentation. The second table records the main data of the host equipment, which helps confirm that the part suits the installation. No pricing is shown on this page, and values not published in the documentation are not included.

Part data

Item Value
Part number 2323-7928
Description Inlet filter O-ring, Chemraz
Intended transducer Solvent-resistant oxygen transducer
Fits 1900 Digital O2 Gas Analyser

Host equipment data

Item Value
Analyser family SERVOTOUGH Oxy 1900, 1900 Digital O2 Gas Analyser
Analyser dimensions (H x W x D) 235 x 448 x 229 mm
Analyser mass 26 kg
Sample flow, standard inlet/outlet T piece 50 to 250 ml/min
Sample flow, high flow bypass T piece 50 to 70 l/h (60 l/h nominal)
Ambient temperature, operation -10 to 50 degrees C
Ingress protection IP65
Supply 100 to 120 V a.c. or 220 to 240 V a.c., 50 to 60 Hz, maximum 50 VA

Typical applications in oil and gas, utilities, water and manufacturing

The 1900 Digital analyser measures oxygen in clean, non-corrosive, oil-free sample gas and is housed for hazardous-area installation, so it is typically found on inerting and blanketing lines, nitrogen generation and purity checks, solvent and chemical plant vapour spaces and similar duties. In Oman and the wider GCC that translates into refineries, gas processing trains, petrochemical units, LNG and storage terminals, plus industrial gas and manufacturing sites where a few percent of oxygen decides whether a line is safe to run.

Gulf conditions add their own demands: high ambient temperature, fine desert dust and coastal humidity all age seals, filters and electronics faster than in temperate climates. A planned stock of spares such as 2323-7928 therefore pays back quickly, because an analyser that is waiting for a part can hold up a start-up, a safety check or an emissions report.

Selection and compatibility notes

Use the 2323-7928 only on analysers fitted with the solvent-resistant transducer. The manual says that on such analysers you must fit the correct type of inlet filter O-ring, otherwise the O-ring may fail during operation. For standard transducers the Viton item is listed instead, so the transducer type is the deciding factor.

The manual for the 1900 Digital analyser states that the unit is not suitable for oxygen-enriched sample gases and that sample gas must be clean, non-corrosive, free from oil and condensate and with particulates smaller than 3 microns, which is exactly why the consumable parts at the sample inlet matter. The same manual warns that spares other than those it specifies can damage the analyser and invalidate its certification, so confirm the analyser model and transducer type before ordering.

When you send an enquiry for 2323-7928, include the analyser model, the serial number or order code, the supply voltage if relevant, and a photograph of the nameplate. That information lets us confirm the match against the manufacturer documentation before a quotation is issued.

Installation and commissioning of 2323-7928

Replacement follows the inlet filter procedure: isolate the sample gas and electrical supply, open the hinged door with the 5 mm hexagonal key, disconnect the transducer pipes, remove the bulkhead, and exchange the O-ring and filter on the sample gas inlet. Fit the 2323-7928 into the seat before the new filter and check that the insulation is correctly positioned on refit.

As with any work on process analysers, follow the site permit-to-work system, isolate sample and electrical supplies, and use only the procedures in the manufacturer manual. After fitting 2323-7928, return the analyser to service in the order the manual describes and confirm the reading with a suitable reference gas before relying on the output for control or alarms.

Maintenance and service life

Because solvent-resistant analysers usually run on more demanding gases, inspect the filter and O-ring more often than the three-month minimum quoted for clean, dry gas. Stock the 2323-7928 alongside 2377-3862 filters so both can be changed in a single shutdown window.

Keep a simple maintenance log for each analyser listing the date, the action and the part number used. When 2323-7928 has been changed, a short note makes it easy to plan the next replacement and gives the manufacturer or an engineer useful history if a fault returns.

Related products and ordering notes

Other items from the same manual that are often ordered with 2323-7928 include 2377-3862 (20 micron stainless steel inlet filter), 2323-7803 (Viton inlet filter O-ring), 204629 (2 A fuse for supply fuse position F101), 2531-2630 (1 A fuse for supply fuse position F101), 2344-2054 (stainless steel adaptor for 1/4 inch outside diameter tube), 2346-3073 (stainless steel adaptor for 6 mm outside diameter tube). Each is a separate part number and is quoted separately. Combining them in one enquiry avoids repeated shipments and shortens the shutdown window.

Many of these numbers belong to older analyser generations. If the manufacturer has superseded a part, we will tell you only if the manufacturer documentation names the replacement. Otherwise we will confirm availability and lead time before you commit to an order.

Frequently asked questions

The questions below summarise what buyers most often ask about 2323-7928.

What is 2323-7928? 2323-7928 is the manufacturer part number for the Chemraz inlet filter O-ring used with the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). It is listed in the spares or parts section of the manufacturer manual.

Which equipment does 2323-7928 fit? It is listed for the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.

Can Seven Star LLC supply 2323-7928 in Oman? Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.

Is a datasheet or manual available for 2323-7928? The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.

What details should I send with my RFQ for 2323-7928? Send the part number 2323-7928, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.

Documents and quotation

The official Servomex SERVOTOUGH Oxy 1900 Digital Operator Manual (01910001A) is attached to this page as a PDF. The Spares chapter (section 10, manual page 65) lists part 2323-7928 as the Chemraz inlet filter O-ring, specified for analysers fitted with the solvent-resistant oxygen transducer. Include part number 2323-7928 and the analyser model and serial number in your inquiry and we will reply with availability and a written quotation.

Other Models in the Servomex 1900 Range

Seven Star LLC supplies models from the Servomex 1900 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Servomex 2377-3862 Inlet Filter 20 um SS for Oxy 1900Gas Analyzer SystemsView details
Servomex 2323-7803 Viton O-Ring for Oxy 1900 Inlet FilterGas Analyzer SystemsView details
Datasheets & Documents
  • PDF Datasheet Servomex SERVOTOUGH Oxy 1900 Digital Operator Manual (official PDF) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Servomex is a British specialist in gas analysis, founded in 1952 by Richard Steel, John Crockett and Ronald Mudie; the name comes from servomechanism. It first made electronic products, then built its first paramagnetic oxygen analyser in 1961 after work with Charles Munday on a paramagnetic sensor. Servomex is based in Crowborough, East Sussex, and is part of Spectris.

Seven Star LLC lists Servomex process, combustion, emissions and portable gas analyzers, plus accessories, and sources them for refineries, petrochemical plants and industrial gas producers in Oman.

SERVOMEX company profile

Founded 1952, United Kingdom
Founders Richard Steel, John Crockett and Ronald Mudie
Headquarters Jarvis Brook, Crowborough, East Sussex
Ownership Spectris plc, since 1999
Key technologies Paramagnetic oxygen sensing (1961), infrared analysis (1969), zirconia oxygen sensors (1981)
Product families MultiExact and SERVOPRO MultiExact analysers, SERVOTOUGH OxyExact and Oxy 1800 oxygen analysers, SERVOTOUGH Laser 3 Plus TDL analysers, SERVOFLEX portable analysers, zirconia combustion analysers

Milestones

  • 1952: Servomex is founded.
  • 1961: The first Servomex paramagnetic oxygen analyser is introduced.
  • 1981: Servomex introduces zirconia oxygen sensors.
  • 1999: Spectris acquires Servomex.

Servomex analyzer families listed

Servomex groups its analyzers under family names that indicate where they can be used. SERVOTOUGH covers analyzers built for hazardous areas and field mounting, SERVOPRO covers units for general purpose areas and analyzer houses, and SERVOFLEX is the portable line. On this page:

  • SERVOTOUGH OxyExact 2200: paramagnetic oxygen analyzer for process control and safety
  • SERVOTOUGH SpectraExact 2500: photometric analyzer for process gas components
  • SERVOTOUGH Laser 3 Plus: compact tunable diode laser analyzer for combustion
  • SERVOPRO 4900 Multigas: multi-component analyzer for emissions monitoring
  • SERVOPRO NanoTrace DF-550E: ultra-trace oxygen analyzer for high purity gases
  • SERVOFLEX Micro i.s. 5100: intrinsically safe portable oxygen analyzer

A flow alarm relay box for the 2700 flue gas analyzer is also listed.

Where Servomex gas analyzers are used

Typical duties are oxygen measurement for inerting and blanketing, vapor recovery and flare header safety, combustion control on fired heaters and reformers, purity control in air separation and electronic gases, and continuous emissions monitoring. In the GCC the main users are refining, petrochemicals, fertilizer, LNG and industrial gas plants.

SERVOMEX products we list

Family Examples
Gas Analyzer Systems SERVOPRO 4900 Multigas Analyzer, SERVOPRO NanoTrace DF-550E Ultra-Trace O…, SERVOTOUGH Laser 3 Plus Combustion TDL G…, SERVOTOUGH OxyExact 2200 Oxygen Analyzer, ServoTough SpectraExact 2500 Gas Analyzer
Portable Test & Measurement Micro i.s. 5100 Portable Oxygen Analyzer
Gas Analyzer Accessories Tough Flue Gas 2700 Flow Alarm Relay Box

Ordering Servomex analyzers and spares: what we need

A Servomex gas analyzer is built to an order code that fixes the measured gas, range, sample wetted materials, outputs and hazardous area approval. For replacements and spare parts, send the model, the serial number and the order code from the data plate. For a new Servomex oxygen analyzer or multigas unit, send the full stream composition, the component and range to be measured, sample pressure and temperature, the area classification, power supply and communication needs. We check the configuration against Servomex documentation before quoting.

Facts checked against Servomex's own 70-year history and company profiles, October 2026.

FAQ

Questions about the Servomex 2323-7928 Chemraz O-Ring for Oxy 1900

Answers from our engineering team on installation, compatibility and integration.

01What is 2323-7928?
2323-7928 is the manufacturer part number for the Chemraz inlet filter O-ring used with the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). It is listed in the spares or parts section of the manufacturer manual.
02Which equipment does 2323-7928 fit?
It is listed for the SERVOTOUGH Oxy 1900 digital oxygen analyser (1900 Digital O2 Gas Analyser). Please confirm the model and serial number with us before ordering, because variants within a family can use different parts.
03Can Seven Star LLC supply 2323-7928 in Oman?
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Send an RFQ with the part number, quantity and delivery location and we will confirm availability.
04Is a datasheet or manual available for 2323-7928?
The part is documented in the manufacturer manual for the host equipment, which lists the part number and description. We can point you to the relevant manual section with your quotation.
05What details should I send with my RFQ for 2323-7928?
Send the part number 2323-7928, the quantity, the analyser model and serial number, the supply voltage where relevant, and the delivery location so we can prepare an accurate quotation.