Hanna HI97734 Free and Total Chlorine HR Photometer

Description

Hanna HI97734 Free and total chlorine high range portable photometer

The Hanna HI97734 is a pocket-sized, single-parameter photometer built for high-dose chlorination where both free and total chlorine must be read up to 10 mg/L. This model measures free and total chlorine in a single meter, with a 0.00 to 10.00 mg/L range, so shock-dosed pools, wash-down water and disinfection tanks do not need dilution. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we quote the HI97734 to industrial and laboratory buyers across Oman and the GCC.

The model number follows Hanna’s HI977xx pattern for dedicated photometers: the last digits identify the chemistry, so HI97734 always means free and total chlorine high range and cannot be reconfigured for another analyte. Reagents carry their own HI93xxx codes, listed below, and must be ordered separately from the meter.

HI97734 technical specifications

Parameter Specification
Manufacturer / part number Hanna Instruments HI97734
Parameter Free and total chlorine high range
Range 0.00 to 10.00 mg/L as Cl2
Resolution 0.01 mg/L
Accuracy at 25 °C ±0.03 mg/L ±3 % of reading
Method Adaptation of US EPA 330.5, DPD colorimetric
Light source LED with narrow-band interference filter at 525 nm
Filter bandwidth / wavelength accuracy 8 nm / ±1.0 nm
Detector Silicon photocell
Cuvette Round, 24.6 mm diameter (22 mm inside)
Data logging 50 readings (auto logging)
Display 128 × 64 pixel monochrome LCD with backlight
Power Three 1.5 V AA alkaline batteries; more than 800 measurements without backlight
Operating environment 0 to 50 °C; 0 to 100 % RH
Ingress protection IP67, floating case
Dimensions / weight 142.5 × 102.5 × 50.5 mm / 380 g with batteries
Warranty Two years

How the HI97734 measurement works

The DPD reaction colours the sample pink in proportion to chlorine; total chlorine adds a third reagent that releases combined chlorine. The meter reads 525 nm absorbance and the high-range reagent B supplies buffering for strongly chlorinated samples.

Inside the case a reference detector tracks the LED output, so battery sag or a warm ambient does not move the blank. A lens gathers the light leaving the cuvette, which is why scratches and small glass imperfections matter less than with a simple colorimeter, and the cap notch locks the cuvette in the same orientation every time. A built-in tutorial mode walks the operator through sampling, reagent quantity and timers on screen, so the instrument can be handed to a technician who is not a chemist.

Reagents, procedure and interferences for HI97734

Free chlorine uses one HI93701-0 packet and 5 mL of HI93734B-0 mixed with 5 mL of sample, with a 1 minute countdown. Total chlorine adds 3 drops of HI93734C-0 on a fresh sample and runs a 2 minute 30 second countdown.

Code Description Quantity per test
HI93701-0 Free Chlorine Reagent 1 packet
HI93734B-0 Free and Total Chlorine HR Reagent 5 mL
HI93734C-0 Total Chlorine Reagent (total only) 3 drops

Reagent sets are supplied as HI93734-01 (100 tests) and HI93734-03 (300 tests). Follow the zeroing order given in the manual for this method, and read within the time the manual allows after the countdown ends.

Known interferences listed for this method:

  • Bromine, chlorine dioxide, iodine, oxidised chromium and manganese, and ozone
  • Alkalinity above 1,000 mg/L CaCO3 as bicarbonate (pH below 8.3), above 25 mg/L as carbonate (pH above 9.0), or acidity above 150 mg/L CaCO3; neutralise with dilute HCl or NaOH
  • Hardness above 500 mg/L CaCO3; shake the sample for about 2 minutes after adding powder

Where the HI97734 sits among Hanna photometers

The HI97734 is the high-range, dual-parameter choice. Use the HI97701 for free chlorine only up to 5 mg/L, the HI97762 for traces, and the HI97725 when cyanuric acid and pH are also part of the routine.

Model Parameter Range LED filter
HI97700 Ammonia low range 0.00 to 3.00 mg/L as NH3-N 420 nm
HI97715 Ammonia medium range 0.00 to 10.00 mg/L as NH3-N 420 nm
HI97733 Ammonia high range 0.0 to 100.0 mg/L as NH4+ 420 nm
HI97701 Free chlorine 0.00 to 5.00 mg/L as Cl2 525 nm
HI97762 Free chlorine ultra low range 0.000 to 0.500 mg/L as Cl2 525 nm
HI97734 Free and total chlorine, high range 0.00 to 10.00 mg/L as Cl2 525 nm
HI97725 Chlorine, cyanuric acid and pH 0.00 to 5.00 mg/L Cl2; 0 to 80 mg/L CYA; 6.5 to 8.5 pH 525 nm
HI97706 Phosphorus 0.0 to 15.0 mg/L as P 525 nm
HI97714 Cyanide 0.000 to 0.200 mg/L as CN– 610 nm
HI97718 Iodine 0.0 to 12.5 mg/L as I2 525 nm
HI97731 Zinc 0.00 to 3.00 mg/L as Zn 575 nm
HI97737 Silver 0.000 to 1.000 mg/L as Ag 575 nm

Selection and ordering checklist for HI97734

  • Confirm you need both free and total chlorine
  • Verify residuals run above about 5 mg/L, otherwise the HI97701 may be simpler
  • Order HI93734-01 or HI93734-03 sets; free and total tests must be run on separate fresh samples
  • Add CAL Check HI97734-11 for validation
  • Decide how combined chlorine (total minus free) will be recorded

Validation, handling and maintenance of HI97734

Free and total chlorine are read on separate fresh samples, never on the same reacted cuvette. Keep one cuvette for each if throughput matters, and validate the optical system with CAL Check HI97734-11 on a defined schedule.

Keep cuvettes clean with the cleaning solution and a lint-free cloth, never touch the lower half of the glass, and store the meter in its carrying case. Replace the three AA cells when the battery icon appears; the meter keeps its logged readings and settings. For long storage between field trips remove the batteries and close the reagent bottles tightly.

Typical applications of HI97734 in Oman and the GCC

Suitable for hotel and resort pools along the Omani coast, water-tanker and storage-tank disinfection, food-plant sanitation rinses, cooling water shock dosing and wastewater disinfection contact chambers where residuals are well above potable levels.

Heat is a practical factor in the Gulf. Reaction times in the manual are given at 25 °C, so samples that sit in a vehicle at much higher temperature should be allowed to equilibrate, and the meter itself is rated for 0 to 50 °C. The sealed optics and IP67 floating case also cope with dust and spray on plant walkdowns.

Information to send with an RFQ for HI97734

  • Quantity of meters and whether reagent sets (HI93734-01 or HI93734-03; CAL Check HI97734-11) and CAL Check cuvettes are also required
  • Sample matrix and expected concentration, so we can confirm the range suits the application
  • Delivery location in Oman or the GCC and required lead time
  • Any need for spare cuvettes, carrying case or cleaning solution
  • Project or tender reference, if applicable

Documents and quotation

The instruction manual for the HI97734 is attached on this page and covers specifications, the reagent procedure, CAL Check validation and error messages.

Send the part number HI97734, the quantity and your delivery location and we will reply with availability and a quotation.

Other Models in the Hanna Hi977xx Photometer Range

Seven Star LLC supplies models from the Hanna Hi977xx Photometer range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Hanna HI97700 Ammonia Low Range Photometer 0-3 mg/LLiquid Analytical SystemsView details
Hanna HI97715 Ammonia Medium Range Photometer 0-10 mg/LLiquid Analytical SystemsView details
Hanna HI97733 Ammonia High Range Photometer 0-100 mg/LLiquid Analytical SystemsView details
Hanna HI97701 Free Chlorine Portable Photometer 0-5 mg/LLiquid Analytical SystemsView details
Hanna HI97762 Ultra Low Range Free Chlorine PhotometerLiquid Analytical SystemsView details
Hanna HI97734 Free and Total Chlorine HR PhotometerLiquid Analytical SystemsYou are viewing this model
Hanna HI97725 Chlorine, Cyanuric Acid and pH PhotometerLiquid Analytical SystemsView details
Hanna HI97706 Phosphorus Portable Photometer 0-15 mg/LLiquid Analytical SystemsView details
Hanna HI97714 Cyanide Portable Photometer 0-0.200 mg/LLiquid Analytical SystemsView details
Hanna HI97718 Iodine Portable Photometer 0-12.5 mg/LLiquid Analytical SystemsView details
Hanna HI97731 Zinc Portable Photometer 0-3.00 mg/LLiquid Analytical SystemsView details
Hanna HI97737 Silver Portable Photometer 0-1.000 mg/LLiquid Analytical SystemsView details
Datasheets & Documents
  • PDF Manual Hanna HI97734 Instruction Manual Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.

Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.

Hanna Instruments company profile

Founded 1978, near Padua, Italy, by Oscar and Anna Nardo
Headquarters Woonsocket, Rhode Island, USA
Leadership Martino Nardo and Pamela Nardo
Early product The pHep pocket pH tester
Product families pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers

Hanna product series

Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.

The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.

Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.

Where Hanna instruments are used

Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.

Hanna Instruments products we list

Family Examples
Portable Test & Measurement Hanna HI97711 Free and Total Chlorine Po…, Hanna HI98190 Waterproof Portable pH and…, Hanna HI98192 Waterproof Portable EC, Hanna HI98193 Waterproof Portable Dissol…, Hanna HI98199 Portable pH, Hanna HI9829 Multiparameter Water Qualit…, Hanna HI98703 Portable Turbidity Meter

Ordering Hanna instruments: what we need

Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.

Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.

FAQ

Questions about the Hanna HI97734 Free and Total Chlorine HR Photometer

Answers from our engineering team on installation, compatibility and integration.

01How wide is the HI97734 range?
It reads 0.00 to 10.00 mg/L as chlorine for both free and total chlorine, with 0.01 mg/L resolution and 0.03 mg/L plus 3 percent of reading accuracy.
02Which reagents are needed?
Free chlorine uses HI93701-0 and HI93734B-0; total chlorine uses HI93734B-0 with HI93734C-0 as well. Sets are HI93734-01 and HI93734-03.
03How long do the tests take?
Free chlorine runs a 1 minute countdown and total chlorine a 2 minute 30 second countdown, both after reagent addition.
04Can free and total be measured in one cuvette?
No. Free and total chlorine must be measured separately with fresh unreacted samples following their own procedures.
05What conditions affect accuracy?
Oxidants such as bromine and ozone, hardness above 500 mg/L, and extreme alkalinity or acidity are the listed interferences; the manual gives corrective steps.