Brand: Hanna Instruments
Hanna HI97706 Phosphorus Portable Photometer 0-15 mg/L
Description
Hanna HI97706 Phosphorus portable photometer
The Hanna HI97706 is a pocket-sized, single-parameter photometer built for phosphorus control in treatment plants, cooling systems and fertiliser or nutrient streams. The meter reads 0.0 to 15.0 mg/L phosphorus, a broader window than low-range phosphate meters, which suits both process dosing control and wastewater monitoring. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer; we quote the HI97706 to industrial and laboratory buyers across Oman and the GCC.
The model number follows Hanna’s HI977xx pattern for dedicated photometers: the last digits identify the chemistry, so HI97706 always means phosphorus and cannot be reconfigured for another analyte. Reagents carry their own HI93xxx codes, listed below, and must be ordered separately from the meter.
HI97706 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Hanna Instruments HI97706 |
| Parameter | Phosphorus |
| Range | 0.0 to 15.0 mg/L as P |
| Resolution | 0.1 mg/L |
| Accuracy at 25 °C | ±0.3 mg/L ±4 % of reading |
| Method | Adaptation of Standard Methods, amino acid method |
| Light source | LED with narrow-band interference filter at 525 nm |
| Filter bandwidth / wavelength accuracy | 8 nm / ±1.0 nm |
| Detector | Silicon photocell |
| Cuvette | Round, 24.6 mm diameter (22 mm inside) |
| Data logging | 50 readings (auto logging) |
| Display | 128 × 64 pixel monochrome LCD with backlight |
| Power | Three 1.5 V AA alkaline batteries; more than 800 measurements without backlight |
| Operating environment | 0 to 50 °C; 0 to 100 % RH |
| Ingress protection | IP67, floating case |
| Dimensions / weight | 142.5 × 102.5 × 50.5 mm / 380 g with batteries |
| Warranty | Two years |
How the HI97706 measurement works
In the amino acid method, orthophosphate forms a molybdate complex that is reduced to a blue colour. Intensity is read at 525 nm after zeroing on the unreacted sample, and the five-minute development time is managed by a built-in countdown.
Inside the case a reference detector tracks the LED output, so battery sag or a warm ambient does not move the blank. A lens gathers the light leaving the cuvette, which is why scratches and small glass imperfections matter less than with a simple colorimeter, and the cap notch locks the cuvette in the same orientation every time. A built-in tutorial mode walks the operator through sampling, reagent quantity and timers on screen, so the instrument can be handed to a technician who is not a chemist.
Reagents, procedure and interferences for HI97706
Fill the cuvette with 10 mL of sample and zero, add 10 drops of HI93706A-0 and one packet of HI93706B-0, mix, then press Read to start the 5 minute countdown.
| Code | Description | Quantity per test |
|---|---|---|
| HI93706A-0 | Phosphorus Reagent A | 10 drops |
| HI93706B-0 | Phosphorus Reagent B | 1 packet |
Reagent sets are supplied as HI93706-01 (100 tests) and HI93706-03 (300 tests). Follow the zeroing order given in the manual for this method, and read within the time the manual allows after the countdown ends.
Known interferences listed for this method:
- Sulfide
- Chloride above 150,000 mg/L
- Magnesium above 40,000 mg/L CaCO3
- Calcium above 10,000 mg/L CaCO3
- Ferrous iron above 100 mg/L
Where the HI97706 sits among Hanna photometers
Phosphorus is a nutrient and scale-control parameter, so the HI97706 complements the ammonia family (HI97700, HI97715, HI97733) in wastewater work. The manual lists high tolerance to chloride and hardness, which helps with brackish and seawater-derived samples.
| Model | Parameter | Range | LED filter |
|---|---|---|---|
| HI97700 | Ammonia low range | 0.00 to 3.00 mg/L as NH3-N | 420 nm |
| HI97715 | Ammonia medium range | 0.00 to 10.00 mg/L as NH3-N | 420 nm |
| HI97733 | Ammonia high range | 0.0 to 100.0 mg/L as NH4+ | 420 nm |
| HI97701 | Free chlorine | 0.00 to 5.00 mg/L as Cl2 | 525 nm |
| HI97762 | Free chlorine ultra low range | 0.000 to 0.500 mg/L as Cl2 | 525 nm |
| HI97734 | Free and total chlorine, high range | 0.00 to 10.00 mg/L as Cl2 | 525 nm |
| HI97725 | Chlorine, cyanuric acid and pH | 0.00 to 5.00 mg/L Cl2; 0 to 80 mg/L CYA; 6.5 to 8.5 pH | 525 nm |
| HI97706 | Phosphorus | 0.0 to 15.0 mg/L as P | 525 nm |
| HI97714 | Cyanide | 0.000 to 0.200 mg/L as CN– | 610 nm |
| HI97718 | Iodine | 0.0 to 12.5 mg/L as I2 | 525 nm |
| HI97731 | Zinc | 0.00 to 3.00 mg/L as Zn | 575 nm |
| HI97737 | Silver | 0.000 to 1.000 mg/L as Ag | 575 nm |
Selection and ordering checklist for HI97706
- Confirm the expected phosphorus value is between 0.1 and 15.0 mg/L
- Order HI93706-01 or HI93706-03 reagent sets separately
- Add HI97706-11 CAL Check cuvettes for validation
- Note the 5 minute reaction time when planning batches
- Check for sulfide and very high magnesium or calcium in the sample
Validation, handling and maintenance of HI97706
Validate with HI97706-11 and keep the cuvettes free of blue residue by cleaning with the Hanna solution. Time-critical readings are protected by the countdown, so do not let the reacted sample stand much beyond the manual guidance.
Keep cuvettes clean with the cleaning solution and a lint-free cloth, never touch the lower half of the glass, and store the meter in its carrying case. Replace the three AA cells when the battery icon appears; the meter keeps its logged readings and settings. For long storage between field trips remove the batteries and close the reagent bottles tightly.
Typical applications of HI97706 in Oman and the GCC
Typical uses in Oman include sewage and industrial effluent plants controlling phosphate removal, desalination plants checking scale-inhibitor dosing, cooling-water treatment contractors, and agricultural or aquaculture sites monitoring nutrient levels in return water.
Heat is a practical factor in the Gulf. Reaction times in the manual are given at 25 °C, so samples that sit in a vehicle at much higher temperature should be allowed to equilibrate, and the meter itself is rated for 0 to 50 °C. The sealed optics and IP67 floating case also cope with dust and spray on plant walkdowns.
Information to send with an RFQ for HI97706
- Quantity of meters and whether reagent sets (HI93706-01 or HI93706-03; CAL Check HI97706-11) and CAL Check cuvettes are also required
- Sample matrix and expected concentration, so we can confirm the range suits the application
- Delivery location in Oman or the GCC and required lead time
- Any need for spare cuvettes, carrying case or cleaning solution
- Project or tender reference, if applicable
Documents and quotation
The instruction manual for the HI97706 is attached on this page and covers specifications, the reagent procedure, CAL Check validation and error messages.
Send the part number HI97706, the quantity and your delivery location and we will reply with availability and a quotation.
Other Models in the Hanna Hi977xx Photometer Range
Seven Star LLC supplies models from the Hanna Hi977xx Photometer range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
Datasheets & Documents
- Manual Hanna HI97706 Instruction Manual Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Hanna Instruments is a maker of analytical instruments for water and liquid testing, founded in 1978 in the Padua area of Italy by Oscar and Anna Nardo. Its early breakthrough was the pHep, an affordable pocket-sized pH tester. The company is now led by the founders' children, Martino and Pamela Nardo, with its headquarters in Woonsocket, Rhode Island, and offers more than 3,000 products.
Seven Star LLC is an independent supplier in Muscat. We list Hanna instruments for water, wastewater and laboratory users in Oman and the GCC.
Hanna Instruments company profile
| Founded | 1978, near Padua, Italy, by Oscar and Anna Nardo |
|---|---|
| Headquarters | Woonsocket, Rhode Island, USA |
| Leadership | Martino Nardo and Pamela Nardo |
| Early product | The pHep pocket pH tester |
| Product families | pHep and HI98 waterproof testers, edge benchtop meters, HI83 multiparameter photometers, Checker HC handheld colorimeters, HI931 and HI932 titrators, process controllers, reagents and calibration buffers |
Hanna product series
Portable meters include the HI98190 pH and ORP meter, the HI98192 EC, TDS and salinity meter, the HI98193 dissolved oxygen and BOD meter, the HI98199 pH, EC and DO meter and the HI9829 multiparameter water quality meter.
The HI98703 is an EPA compliant portable turbidity meter, the HI97711 a free and total chlorine photometer and the HI83414 a benchtop turbidity and chlorine meter.
Waterproof portable meters such as the HI98190 and HI98192 suit field use, with automatic temperature compensation and GLP data for audits. Turbidity measurement with the HI98703 follows EPA method 180.1, and the HI97711 photometer measures free and total chlorine for disinfection control.
Where Hanna instruments are used
Drinking water and desalination plants, wastewater treatment, environmental field surveys, aquaculture, cooling water and quality control labs.
Hanna Instruments products we list
Ordering Hanna instruments: what we need
Send the model, the parameters and ranges, the probe and cable length and any reagents or calibration solutions required.
Facts checked against Hanna Instruments' own company story and City of Woonsocket business profile, October 2026.
Browse Hanna Instruments products by category: Portable Test & Measurement.
FAQ
Questions about the Hanna HI97706 Phosphorus Portable Photometer 0-15
Answers from our engineering team on installation, compatibility and integration.
01What does the HI97706 measure?
Phosphorus from 0.0 to 15.0 mg/L as P with 0.1 mg/L resolution, using an adaptation of the amino acid method from Standard Methods.
02How long is the reaction time?
The meter runs a 5 minute countdown after reagents A and B are added; pressing Read twice skips the timer if required.
03Which reagents does it use?
HI93706A-0 (10 drops) and HI93706B-0 (one packet) per test, sold as HI93706-01 for 100 tests or HI93706-03 for 300 tests.
04What are the main interferences?
Sulfide, and very high levels of chloride, magnesium, calcium or ferrous iron, with the thresholds given in the manual.
05Is a validation kit available?
Yes, HI97706-11 CAL Check cuvettes verify the meter and allow a user calibration if needed.


















Reviews