Brand: Fluke
Fluke 700G06 Precision Pressure Test Gauge, 100 psi
Description
700G06 precision pressure test gauge for 100 psi calibration work
The Fluke 700G06 is a digital precision pressure test gauge with a range of -12 to 100 psi (-0.83 to 6.9 bar) and an accuracy of 0.05 % of full scale. It belongs to the 700G series, a family of handheld digital gauges used as the reference in pressure calibration with a hand pump. It has a 5.5 digit display with a bar graph, a 1/4 in NPT male connection and works on any liquid or gas compatible with 316 stainless steel at this range. Seven Star LLC supplies the 700G06 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
The model code decodes as follows.
| Element | Meaning | Detail |
|---|---|---|
| 700G | Series | Precision digital pressure test gauge |
| 06 | Range code | 100 psig range (-12 to 100 psi) |
| G / A / RG | Series suffixes | G is gauge, GA is absolute, RG is reference-class gauge; this page covers the standard gauge 700G06 |
700G06 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / 700G06 |
| Range | -12 psi to 100 psi (-0.83 bar to 6.9 bar) |
| Resolution | 0.01 psi, 0.0001 bar |
| Accuracy | ±0.05 % of full scale for positive pressure; ±0.1 % of full scale for vacuum |
| Burst pressure | 400 psi (26 bar) |
| Media | Liquids or gases compatible with 316 stainless steel (100 psi and above) |
| Connection | 1/4 in NPT male; 1/4 in NPT to 1/4 in ISO adapter included |
| Display | 5.5 digits, 16.53 mm high, with a 20-segment bar graph, 0 to 100 % |
| Housing / weight | Cast zinc-aluminium / 0.56 kg with holster |
| Dimensions | 12.7 x 11.4 x 3.7 cm |
| Power | Three AA alkaline batteries |
| Battery life | 1,500 hours without backlight; 2,000 hours at slow sample rate |
| Temperature compensation | 0 °C to 50 °C to rated accuracy |
| Logging | Up to 8,493 readings with 700G/TRACK software and cable (sold separately) |
| Hazardous area rating | CSA Class 1, Div 2, Groups A-D; ATEX II 3 G Ex ic IIB T6 Gc |
| Warranty | Three years |
| Supplied with | Traceable certificate of calibration, 1/4 in NPT to ISO adapter |
How the 700G06 is used as a reference
A test gauge is connected in parallel with the device under test to the same pressure source. A hand pump from the 700PTP-1 (pneumatic, up to 600 psi) or 700HTP-2 (hydraulic, up to 10,000 psi) generates pressure, and the technician compares the gauge reading with the transmitter output or the dial of a mechanical gauge. At 100 psi, the 700G06 is below the 1,000 psi limit of the pneumatic kit, so it fits the pneumatic test pump kit directly. The gauge is not a calibrator: it displays pressure only, so a multimeter or loop calibrator is needed to read a transmitter output.
The 700R reference-class gauges in the same series reach 0.04 % of reading plus 0.01 % of range accuracy. The standard 700G06 is the choice when 0.05 % of full scale is adequate for the tolerance of the devices you test.
Kits and accessories for the 700G06
The datasheet lists the Fluke-700PTPK pneumatic test pump kit, the 700PTPK2 premium pneumatic test pump kit, transmitter test hose kits rated to 5,000 or 10,000 psi, M20 and metric hose kits, and the 700G/TRACK data logging software. The hard case of the pump kits holds both the pump and gauge so they stay connected. Check which hose or adapter matches the thread on the device under test, as NPT, BSP and M20 fittings all appear on plant equipment.
Selecting the 700G06
- Choose a range so that your test points lie between 20 % and 100 % of the gauge span.
- Select the 700RG06 reference version if you need accuracy to 0.04 % of reading.
- Decide on a pump kit: the pneumatic kit for gas, the hydraulic kit for higher pressure and liquids.
- Check the media: at 100 psi and above, 316 stainless steel compatible fluids are acceptable.
- Order the data logging software if you want to record pressure over time.
Use and maintenance of the 700G06
Zero the gauge at atmospheric pressure before each use. Stay below the burst pressure of 400 psi and use a pressure relief valve when connected to a source that can exceed the range. Use thread sealant suitable for the fitting, and do not overtighten the cast housing. The temperature compensation holds rated accuracy between 0 °C and 50 °C, with extra error of 0.005 % of full scale per degree outside that range down to -10 °C and up to 55 °C. Keep the gauge in its holster and send it for periodic recalibration.
Typical applications of the 700G06 in Oman and the GCC
The 700G06 is used in instrument workshops and in the field for checking pressure transmitters, pressure switches and mechanical gauges in oil and gas, water treatment, desalination and power plants. Its Class 1 Div 2 and ATEX Zone 2 ratings suit work in classified areas where a standard electronic gauge would not be permitted, subject to your site’s permit and the markings on the gauge.
Information to send with an RFQ for the 700G06
- Part number 700G06 (or the reference version 700RG06)
- Quantity and pump kit, hose kit or logging software
- Pressure range, media and thread type
- Delivery location and time frame
- Calibration certificate requirement
Storage, handling and spares for the Fluke 700G06
Keep the Fluke 700G06 in its carrying case when it is not in use, and store it in a clean, dry place. Remove or charge the batteries as recommended in the user manual before long storage. Field teams in Oman and the GCC should avoid leaving the instrument in a vehicle in the sun, as high cabin temperatures can exceed the storage range and shorten battery life.
- Check the instrument, cables, hoses or lenses for damage before each job.
- Clean the unit with a soft, slightly damp cloth only; do not use solvents unless the manual allows them.
- Plan a calibration interval that matches your quality system, and keep the calibration certificate with the asset record.
- Order wear parts and accessories, such as batteries, test leads, hoses or adapters, together with the instrument.
For calibration and test work, it helps to state in your RFQ whether you need an accredited calibration certificate with the Fluke 700G06, so the right documents can be confirmed with the quotation.
Documents and quotation
A datasheet covering the 700G series is attached on this page.
Send us the part number 700G06 and the quantity and we will confirm availability and a quotation.
Other Models in the Fluke 700g Gauge Range
Seven Star LLC supplies models from the Fluke 700g Gauge range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Fluke 700G27 Precision Pressure Test Gauge, 300 psi | Process, Pressure & Temperature Calibrators | View details |
| Fluke 700G06 Precision Pressure Test Gauge, 100 psi | Process, Pressure & Temperature Calibrators | You are viewing this model |
Datasheets & Documents
- Datasheet Fluke 700G06 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 700G06 Precision Pressure Test Gauge, 100 psi
Answers from our engineering team on installation, compatibility and integration.
01What range does the Fluke 700G06 cover?
The 700G06 covers -12 psi to 100 psi (-0.83 bar to 6.9 bar), with 0.01 psi resolution and a burst pressure of 400 psi (26 bar).
02How accurate is the Fluke 700G06?
The datasheet gives 0.05 % of full scale for positive pressure and 0.1 % of full scale for vacuum, with temperature compensation from 0 °C to 50 °C.
03Is the Fluke 700G06 approved for hazardous areas?
The datasheet states CSA Class 1, Div 2, Groups A-D and ATEX II 3 G Ex ic IIB T6 Gc. Confirm the markings on the gauge against your site requirements.
04What pump kits work with the Fluke 700G06?
It can be combined with the 700PTPK pneumatic test pump kit for pressure up to 600 psi. The 700HTPK hydraulic kit is intended for gauges rated 1,000 psi or more.
05What batteries does the Fluke 700G06 use?
It uses three AA alkaline batteries, giving about 1,500 hours without backlight on continuous use or 2,000 hours at a slow sample rate.