Schneider Electric ATS490C11Y Altivar ATS490 Soft Starter 110 A

Description

ATS490C11Y: Altivar ATS490 soft starter, 110 A normal duty

The ATS490C11Y is a Schneider Electric Altivar Soft Starter ATS490 for three-phase asynchronous motors. It is rated 110 A in normal duty and 88 A in heavy duty at 40 °C, which the datasheet pairs with 55 kW at 400 V in normal duty (line connection) and up to 90 kW at 690 V. This unit runs from 208 to 690 V AC with a 110 to 230 V AC control supply and targets process and infrastructure duty. Seven Star LLC supplies the ATS490C11Y in Oman and the GCC as an independent supplier based in Muscat.

Reading the reference against the datasheet: the letter C groups ratings of 110 A and above, the digits 11 match the normal duty current (in tens of amps) and Y goes with the 110 to 230 V AC control supply. This is our reading, not a published ordering table.

Selection checklist for the ATS490C11Y

  • Motor full-load current at the actual supply voltage compared with 110 A (normal duty) or 88 A (heavy duty).
  • Starts per hour against the 10 cycles per hour limit, and whether the load needs heavy duty figures.
  • Fieldbus needed: Modbus serial, Modbus TCP / EtherNet/IP, or an option card such as PROFINET or Profibus.
  • Cabinet space for 289 × 160 × 234 mm and a heat budget of about 51 W at full load.

Mounting, heat and clearances for the ATS490C11Y

The datasheet lists degree of protection IP20. At 7 kg and 289 × 160 × 234 mm, the ATS490C11Y needs a back plate or frame that can carry the weight and a cabinet with enough height and depth for the air path. The datasheet requires vertical mounting within ± 10 degrees and tells you to keep the stated minimum clearances so that cooling air can travel from bottom to top. Clearances apply to neighbouring breakers, fuses and contactors, and the starter must not sit above heating elements. The datasheet lists 19 W of load-independent loss and 32 W of current-dependent loss for this rating, which adds up to 51 W at rated current once the internal bypass is closed. Add that figure to the other heat sources in the cabinet.

Ambient is −25 to 40 °C without derating and up to 60 °C with 1 % per degree above 40. Pollution degree 3 and rated insulation voltage 690 V are listed.

Functions, protection and communication of the ATS490C11Y

Starting uses torque control. The datasheet lists controlled deceleration, braking, boost, jog, anti-jam, a second motor set, borehole pump starting, contactor control, pre-heating, smoke extraction, condition and power monitoring, and current limiting from 150 to 700 % of In. The overload profile is 400 % of Ie for 13 s at a 50 % on-load factor and 10 cycles per hour, so a ATS490C11Y is not meant for a motor that restarts every few minutes. A start at 400 % of Ie dissipates 1471 W until the internal bypass closes. Arrange restarts after trips to stay inside it.

Protection covers mains phase failure, thermal protection of motor and starter, overload, underload, long acceleration, phase loss, phase inversion and earth faults, class 10E, with PTC, PT100, PT1000 or KTY84 probe inputs. I/O is five digital inputs (one is STO, SIL 1), three 2 A relay outputs, two open-collector outputs and one analogue in and out. Modbus serial and Modbus TCP / EtherNet/IP have separate RJ45 ports; options cover CANopen, Profibus DP V1 and PROFINET.

Technical specifications of the ATS490C11Y

Parameter Specification
Manufacturer / part number Schneider Electric / ATS490C11Y
Range of product Altivar Soft Starter ATS490
Power supply 3 phases, 208–690 V AC (−15 / +10 %)
Supply frequency 50–60 Hz ± 20 %
Rated operational current, normal duty 110 A in line, below 40 °C
Rated current, heavy duty 88 A at 40 °C
Motor power in line, normal duty 30 kW at 230 V; 55 kW at 400 V; 75 kW at 500 V; 90 kW at 690 V
Motor power in line, heavy duty 22 kW at 230 V; 45 kW at 400 V; 55 kW at 500 V; 75 kW at 690 V
Overload profile 400 % Ie for 13 s; on-load factor 50 %; 10 cycles per hour
Control supply 110–230 V AC, 80 VA
Inputs / outputs 5 digital (incl. STO), 3 relay, 2 digital outputs, 1 analogue in, 1 analogue out
Communication Modbus serial; Modbus TCP / EtherNet/IP
Dimensions (H x W x D) 289 × 160 × 234 mm
Net weight 7 kg
Degree of protection IP20
Operating temperature −25 to 40 °C without derating; 40 to 60 °C with 1 % current derating per °C
Operating altitude Up to 2000 m without derating; 2000 to 4800 m with 1 % per 100 m

Normal duty and heavy duty ratings of the ATS490C11Y

The same hardware carries 110 A in normal duty and 88 A in heavy duty, the latter meant for harder or longer starts. Motor sizes for the line connection are shown below.

Motor supply voltage Normal duty (kW) Heavy duty (kW)
230 V 30 22
400 V 55 45
500 V 75 55
690 V 90 75

For the inside-delta connection the datasheet lists 55 kW at 230 V and 90 kW at 400 V in normal duty, and 45 kW at 230 V and 75 kW at 400 V in heavy duty. The same starter is listed at 75 hp (normal) and 60 hp (heavy) at 460 V. Pick the column that matches how the load really starts.

Use in Oman and the GCC, commissioning and care of the ATS490C11Y

At 110 A the ATS490C11Y is aimed at large pumps, compressors, fans and conveyors on process and utility plants, including desalination feed pumps and cooling-water systems in the Gulf. Starting current control keeps the voltage dip on the plant bus within what the supply can accept. Fine dust and sand make filter maintenance part of the plan.

Before first start, verify motor data, connection type (line or inside-delta), control supply and phase rotation, since the unit monitors phase inversion. Set the current limit and start and stop behaviour, and test the STO input and relay outputs. For a spare unit, keep the parameter file so a replacement can be set to the same configuration.

In service, watch the condition and power monitoring values, keep air paths clear, check terminal tightness at shutdowns and keep the motor probe wiring intact. The datasheet records a removable battery, so include it in routine checks.

The ATS490C11Y among neighbouring ATS490 ratings

All ATS490 references in this group share the same supply ranges, functions, communication and protection list; they differ in current, motor size, frame, weight and heat. The nearest ratings by normal duty current are compared below.

Reference Normal duty current kW at 400 V (normal duty) Size H × W × D Weight
ATS490D75Y 75 A 37 289 × 160 × 234 mm 7 kg
ATS490D88Y 88 A 45 289 × 160 × 234 mm 7 kg
ATS490C11Y 110 A 55 289 × 160 × 234 mm 7 kg
ATS490C14Y 140 A 75 356 × 160 × 235 mm 10 kg
ATS490C17Y 170 A 90 356 × 160 × 235 mm 10 kg

When two references both seem to fit, the heavy duty column and the number of starts per hour usually settle the choice.

Information to send with an RFQ for the ATS490C11Y

  • Reference ATS490C11Y and quantity.
  • Motor power, full-load current, voltage and connection type (line or inside-delta).
  • Load type, starting time and number of starts per hour.
  • Control supply voltage and the fieldbus or option card needed.
  • Ambient temperature and altitude at the installation.
  • Delivery location and deadline.

Documents and quotation

The manufacturer datasheet for the ATS490C11Y is attached on this page. It holds the full specification table, the dimension drawings and the mounting and wiring pages summarised above.

Send us the reference ATS490C11Y, the quantity and the delivery location and Seven Star LLC will reply to your request for quotation. We are an independent supplier based in Muscat.

Other Models in the Se Ats490 Range

Seven Star LLC supplies models from the Se Ats490 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric ATS490C11Y Altivar ATS490 Soft Starter 110 AMotor Soft StartersYou are viewing this model
Schneider Electric ATS490C14Y Altivar ATS490 Soft Starter 140 AMotor Soft StartersView details
Schneider Electric ATS490C17Y Altivar ATS490 Soft Starter 170 AMotor Soft StartersView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric ATS490C11Y Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric ATS490C11Y Altivar ATS490 Soft

Answers from our engineering team on installation, compatibility and integration.

01What current is the ATS490C11Y rated for?
The datasheet gives 110 A in normal duty below 40 °C and 88 A in heavy duty at 40 °C. Heavy duty is for harder or longer starts.
02Which motor sizes does the ATS490C11Y cover?
In the motor supply line, normal duty: 30 kW at 230 V, 55 kW at 400 V and 90 kW at 690 V. Heavy duty values are lower, for example 45 kW at 400 V.
03What supplies does the ATS490C11Y need?
Power from 208 to 690 V AC at 50-60 Hz and a control supply of 110 to 230 V AC. The I/O side uses 24 V DC signals.
04What communication does the ATS490C11Y offer?
Modbus serial and Modbus TCP / EtherNet/IP on separate RJ45 ports, plus option cards for CANopen, Profibus DP V1 and PROFINET.
05What are the size and weight of the ATS490C11Y?
289 × 160 × 234 mm and 7 kg, with degree of protection IP20.