Brand: Schneider Electric
Schneider Electric LC1D115ABNE 115 A Contactor 24-60 V AC/DC
Description
LC1D115ABNE contactor: 115 A frame, connector terminals, 24-60 V AC/DC coil
The LC1D115ABNE is a Schneider Electric TeSys Deca contactor with connector terminals, a 24-60 V AC/DC coil and a 115 A AC-3 rating. The datasheet title reads: Contactor Deca 115A 3P 24-60V ACDC EvLk. The LC1D115 is the 115 A frame of the TeSys Deca range, a heavy contactor rated 115 A in AC-3 and AC-3e at up to 440 V and 200 A in AC-1. It is built for motors of 55 kW at 400 V and for large resistive or capacitor-free switching duties, in a body 152 mm tall, about 99 mm wide and 155 mm deep. Seven Star LLC supplies the LC1D115ABNE in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: LC1D115 is the 115 A TeSys Deca frame, the A group marks the connector terminals version, and BNE is the coil code for 24 to 60 V AC 50/60 Hz and 24 to 60 V DC. The same coil on the other terminal style is LC1D115A6BNE. The datasheet gives a body of 152 x 97 x 155 mm (H x W x D) and a net weight of 2.4 kg.
Connector terminals on the LC1D115ABNE
The LC1D115ABNE has connector-type power terminals in place of ring lugs. A bare or ferruled cable is clamped directly, so no lug crimping is needed and terminations can be redone quickly during maintenance.
In the references of this family, the part number without the 6 after the A marks the connector version. The datasheet title describes it as ‘connector’ and the sibling A6 references as ‘lugs-ring or bars’.
Technical specifications of the LC1D115ABNE
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LC1D115ABNE |
| Description | Contactor Deca 115A 3P 24-60V ACDC EvLk |
| Range of product | TeSys Deca Advanced (range: TeSys Deca) |
| Device short name | LC1D |
| Product or component type | Contactor |
| Contactor application | Motor control; resistive load |
| Utilisation category | AC-3; AC-3e; AC-1; AC-4; DC-1; DC-3; DC-5 |
| Poles / contact composition | 3P; 3 NO |
| Rated operational voltage [Ue] | Power circuit: up to 1000 V AC (16.67 to 400 Hz); up to 300 V DC |
| Rated operational current [Ie] | 115 A at <60 °C at up to 440 V AC (AC-3 and AC-3e); 200 A in AC-1 |
| Control circuit voltage [Uc] | 24 to 60 V AC 50/60 Hz and 24 to 60 V DC |
| Control voltage limits | 0.8 Uc min to 1.1 Uc max operational; 0.1 Uc max drop-out (-40 to 60 °C) |
| Coil technology | Built-in bidirectional peak limiting diode suppressor |
| Inrush power | 170 VA; 136 W (at 20 °C) |
| Hold-in power | 7.5 VA; 5.1 W (at 20 °C) |
| Motor power (AC-3), 400 V | 55 kW at 400 V |
| Motor power, 60 Hz | 75 hp at 460/480 V |
| Conventional free-air thermal current | 200 A at 60 °C |
| Making / breaking capacity at 440 V | 1560 A at 440 V / 1100 A at 440 V |
| Associated fuse rating | 125 A aM at up to 440 V, 100 A aM at up to 690 V, 200 A gG at up to 690 V |
| Power dissipation | 6 W per pole in AC-3, 22 W in AC-1 |
| Mechanical durability | 8 Mcycles |
| Electrical durability | 1 Mcycles at 115 A AC-3; 0.5 Mcycles at 200 A AC-1 |
| Maximum operating rate | 2400 cycles per hour at 60 °C; 3600 at Uc, 20 °C |
| Operating time | 20 to 90 ms closing; 10 to 80 ms opening |
| Power terminals | Connector 1: 10 to 120 mm²; connector 2: 10 to 50 mm² |
| Tightening torque (power) | 12 N.m on hexagonal screw head 4 mm |
| Auxiliary contacts | 1 NO + 1 NC, mechanically linked; NC mirror contact |
| Mounting support | Plate |
| IP degree of protection | IP20 front face (IEC 60529) |
| Protective treatment | None (IEC 60068-2-30) |
| Ambient temperature | -40 to 60 °C operation; 60 to 70 °C with derating; storage -60 to 80 °C |
| Operating altitude | 0 to 3000 m without derating |
| Dimensions (H x W x D) | 152 x 97 x 155 mm |
| Net weight | 2.4 kg |
| Product certifications | CB Scheme; CCC; cULus; CE; UKCA; EU-RO-MR by DNV-GL |
What the LC1D115ABNE switches: ratings, endurance and protection
At 115 A AC-3 the datasheet lists 30 kW at 230 V, 55 kW at 400 V, 59 kW at 415 V, 75 kW at 500 V, 80 kW at 690 V and 65 kW at 1000 V. The utilisation categories listed are AC-3, AC-3e, AC-1, AC-4, DC-1, DC-3 and DC-5.
| Supply voltage (AC-3) | Motor power |
|---|---|
| 230 V | 30 kW |
| 400 V | 55 kW |
| 415 V | 59 kW |
| 500 V | 75 kW |
| 690 V | 80 kW |
| 1000 V | 65 kW |
Making capacity is 1560 A at 440 V and breaking capacity 1100 A at 440 V. Power dissipation per pole is 6 W in AC-3 and 22 W in AC-1.
Mechanical life is 8 million cycles; electrical life is 1 million cycles at 115 A AC-3 and 0.5 million at 200 A AC-1 (all at up to 440 V). The datasheet’s maximum operating rate is 2400 cycles per hour at 60 °C, and the safety data gives B10d of 684932 cycles at nominal load.
Power circuit insulation is rated 1000 V to IEC 60947-4-1 with an impulse withstand of 8 kV, overvoltage category III and pollution degree 3. Contact impedance is 0.45 mΩ at 200 A and 50 Hz.
Control voltage 24-60 V AC/DC: the coil of the LC1D115ABNE
The coil of the LC1D115ABNE is a wide-range AC/DC type: 24 to 60 V AC 50/60 Hz and 24 to 60 V DC. The datasheet states operational limits of 0.8 Uc minimum to 1.1 Uc maximum and a drop-out at or below 0.1 Uc, over -40 to 60 °C, for both AC and DC. Applied to this range, 0.8 x 24 V is 19.2 V and 1.1 x 60 V is 66 V. The coil carries a built-in bidirectional peak limiting diode suppressor, so a separate suppressor is not normally needed. Because this coil accepts both AC and DC across 24 to 60 V, it is a practical spare for plants with mixed control voltages. Check the lowest voltage the control supply can reach during a battery discharge or a heavy load step, since the datasheet gives a pull-in threshold of 0.8 Uc (about 19 V at the bottom of the range).
Commissioning check on a 24 to 60 V coil: measure the DC voltage at the coil terminals under closing, not at the power supply. The pull-in limit is 0.8 Uc of the band’s lower value, so a 24 V system that sags below about 19 V will fail to close. Drop-out is at 0.1 Uc, so a released coil should read well below 6 V.
Wiring a 24 to 60 V coil: low-voltage DC is usually distributed from a regulated power supply, so size that supply for the 170 VA (136 W for this coil) closing demand and make sure the cable volt drop at the contactor stays above 0.8 Uc. A reverse-polarity diode is not needed because the coil is rated for AC and DC.
Typical homes for the LC1D115ABNE: PLC-driven motor starters on 24 V DC control rails, battery-backed 48 V systems in telecom and remote sites, and machines where the contactor must be switched by a relay or transistor output without any mains-level control wiring.
Points to confirm before ordering the LC1D115ABNE
- Motor size: up to 55 kW at 400 V in AC-3, 59 kW at 415 V.
- Whether the starter is direct-on-line or a star-delta or soft-starter bypass, since the contactor sees different currents.
- Coil voltage band (24-60, 48-130, 100-250 or 200-500 V AC/DC) and available control power.
- Terminal style: ring lugs or busbars (A6 references) versus connector (A references).
- Fuse or breaker for short-circuit protection: 125 A aM at up to 440 V per the datasheet.
- Overload protection: electronic overload relay or motor protection suitable for 115 A frames.
- Check the control supply type (24 V DC, 48 V DC or 24 to 60 V AC) and that it can supply the closing power of the coil, not only the hold-in.
- Confirm the 24-60 V AC/DC control supply can deliver the 170 VA inrush at the lowest voltage it reaches in operation.
Coil options beside the LC1D115ABNE on the connector version
The table lists the 115 A connector terminals references in this series; the coil code is the only difference inside the group. The ring lug and busbar twin with the same coil is LC1D115A6BNE.
Against the other coil bands of this frame, the 24 to 60 V AC/DC coil is the lowest-voltage choice and the only one that can be driven from a 24 V DC rail. The 48 to 130 V band starts at 48 V and cannot close reliably on 24 V, so the two are not interchangeable at the bottom of their ranges.
| Part number | Coil band | Terminals | Note |
|---|---|---|---|
| LC1D115A6BNE | 24-60 V AC/DC | lugs-ring or bars | Same frame |
| LC1D115A6EHE | 48-130 V AC/DC | lugs-ring or bars | Same frame |
| LC1D115A6KUE | 100-250 V AC/DC | lugs-ring or bars | Same frame |
| LC1D115A6LSE | 200-500 V AC/DC | lugs-ring or bars | Same frame |
| LC1D115ABNE | 24-60 V AC/DC | connector | This page |
| LC1D115AEHE | 48-130 V AC/DC | connector | Same frame |
| LC1D115AKUE | 100-250 V AC/DC | connector | Same frame |
| LC1D115ALSE | 200-500 V AC/DC | connector | Same frame |
Typical applications of the LC1D115ABNE in Oman and the GCC
A 115 A contactor typically starts 45 to 55 kW pumps, large fans, compressors and crushers, and is also used for switching resistive banks and transformer-fed heating. In Oman and the GCC it is found in MCC starter buckets for water treatment, in desalination feed pump drives and in industrial ventilation.
The datasheet lists a protective treatment of ‘None’ for this frame, against ‘TH’ on the compact 9 to 25 A contactors, so a heavy contactor in a humid or salt-laden coastal atmosphere should be inside a sealed, ventilated panel instead of exposed to air. Summer temperatures in the region also call for attention to the 60 °C operating limit and the derating up to 70 °C given in the datasheet.
Information to send with an RFQ for the LC1D115ABNE
- The reference LC1D115ABNE and the quantity required
- The coil voltage on any contactor it replaces, and whether the control is AC or DC
- Motor power, supply voltage and starter type, so the 115 A frame can be confirmed
- Terminal style on site: ring lugs or busbars, or connector terminals
- Delivery location and timing, and whether the item is a spare or new installation
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number LC1D115ABNE, the quantity and the application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric LC1D115ABNE Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LC1D115ABNE 115 A Contactor
Answers from our engineering team on installation, compatibility and integration.
01What is the AC-3 rating of the LC1D115ABNE?
The datasheet lists 115 A at up to 440 V in AC-3 and AC-3e, and 200 A in AC-1.
02What coil voltage range does the LC1D115ABNE accept?
The control circuit voltage is 24 to 60 V AC 50/60 Hz and 24 to 60 V DC; operational limits are 0.8 Uc minimum to 1.1 Uc maximum.
03How are the power circuits of the LC1D115ABNE connected?
It has connector terminals; the power circuit tightening torque in the datasheet is 12 N.m.
04What motor power does the LC1D115ABNE cover at 400 V?
The datasheet gives 55 kW at 400 V in AC-3, and 75 hp at 460/480 V for 60 Hz motors.
05How big and heavy is the LC1D115ABNE?
The datasheet lists 152 x 97 x 155 mm (H x W x D) and a net weight of 2.4 kg.