Schneider Electric LADR2 TeSys D Off-Delay Timer Block 1-30 s
Description
LADR2: off-delay timer block covering 1 to 30 seconds
The LADR2 is a Schneider Electric TeSys D time delay auxiliary contact block with an off-delay function and a range of 1 to 30 seconds. It is the mid-range off-delay unit and the one most users reach for when a few seconds is not enough. Seven Star LLC supplies the LADR2 in Oman and the GCC as an independent supplier based in Muscat.
Compared with the LADR0 (0.3 to 3 s), the LADR2 stretches the range ten times while keeping the same off-delay logic, contacts and housing.
Technical specifications of the LADR2
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LADR2 |
| Description | Product datasheet Time delay auxiliary contact block, TeSys D, 1NO + 1NC, off delay 1-30s, front, screw clamp terminals |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Time delay auxiliary contact block |
| Range compatibility | TeSys Deca CAD; TeSys Deca LC1D; TeSys F LC1F; TeSys F CR1F |
| Mounting location | Front |
| Pole contact composition | 1 NO + 1 NC |
| Contacts operation | Time delay |
| Timer type | Off delay |
| Time delay range | 1 to 30 s |
| [Ue] rated operational voltage | 690 V AC 25 to 400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL 60947-5-1; 600 V conforming to CSA C22.2 No 60947-5-1 |
| [Ith] conventional free air thermal | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; UL 60947-5-1; CSA C22.2 No 60947-5-1; GB/T 14048.5; EN 50012; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | IECEE CB Scheme; UL; CSA; CCC; EAC; UKCA |
| Irms rated making capacity | 140 A at <= 690 V AC conforming to IEC 60947-5-1; 250 A at <= 690 V DC conforming to IEC 60947-5-1 |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms; are subject to change – check with your local distributor. |
| Protection type | GG fuse 10 A |
| Mechanical durability | 5 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections – terminals | Screw clamp terminals 1 cable(s) 1 to 2.5 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1 to 2.5 mm²flexible without cable end |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 61 mm |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP20 conforming to IEC 60529 |
| Ambient air temperature (operation, as listed) | -40 to 70 °C |
| Operating altitude | 3000 m |
LADR2 electrical and mounting data
The block fits on the front of TeSys D and TeSys Deca contactors and CAD relays, and on TeSys F LC1F and CR1F, which is the range compatibility line in the datasheet. It has one normally open and one normally closed time-delayed contact and measures 48 mm high, 44 mm wide and 61 mm deep. Rated operational voltage is 690 V AC at 25 to 400 Hz, thermal current is 10 A at 60 °C, rated current is 6 A at 120 V AC-15 and 1.04 A at 690 V AC-15, and the making capacity is 140 A AC. Mechanical durability is 5 Mcycles, the minimum switching level is 5 mA at 17 V, and the protection is IP20. The ambient air temperature range is -40 to 70 °C and the altitude limit is 3000 m.
LADR2 ordering checklist
- Function: off delay with 1 to 30 s range.
- Contacts: one NO and one NC, time delayed.
- Check mechanical space: 61 mm depth in front of the contactor.
- Check the contactor family against the list in the datasheet.
- Alternative: LADR0 for 0.3 to 3 s.
Choosing between the LADR0 and LADR2 delay ranges
The delay dial of a block works best in the middle of its scale. If the needed time is 2 to 3 seconds, either block would work, but the LADR2 would run at the low end where the scale is compressed, while the LADR0 would run near the top. For 5 to 25 seconds the LADR2 is the natural fit.
Beyond 30 seconds neither off-delay block applies, and a separate timing relay is the better answer.
LADR2 in Oman and GCC plants
Run-on timers of 10 to 30 s are common for cooling fans on large motors and drives, for lube-oil pumps after compressor stop, and for post-purge on small burners and heaters.
Skid-mounted equipment from export builders often includes this block, and it is a standard spare.
Timer block family: the LADR2 against its siblings
The five timer blocks below share the housing and contact ratings and differ in function and range.
| Reference | Timer type | Delay range | Application noted |
|---|---|---|---|
| LADR0 | Off delay | 0.3 to 3 s | Not stated |
| LADR2 | Off delay | 1 to 30 s | Not stated |
| LADS2 | On delay | 1 to 30 s | Star delta starter |
| LADT2 | On delay | 1 to 30 s | Not stated |
| LADT4 | On delay | 10 to 180 s | Not stated |
Commissioning the LADR2
Fit the block, tighten the terminals to 1.7 N.m, then set the delay with the contactor energised and measure it with a stopwatch. Record the set time on the maintenance card.
Re-measure after a service, because a block that has been knocked or has aged may drift from its dial setting.
Information to send with an RFQ for the LADR2
- Full reference and quantity required
- Contactor model the block mounts on
- Delay function (on or off) and time range needed
- Control voltage and load of the timed contacts
- Delivery location and timing
Storage, handling and spares for the LADR2
Keep the LADR2 in its original packaging in a dry, dust-free store until installation, and check the label against the order before fitting. For plants that run continuously, holding one spare unit on site shortens downtime if a replacement is needed during a shutdown or after a fault. Record the reference and installation date in the maintenance log so the next order can be placed quickly.
Documents and quotation
A datasheet for the LADR2 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.
Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Tesys D Timer Range
Seven Star LLC supplies models from the Se Tesys D Timer range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric LADR0 TeSys D Off-Delay Timer Block 0.3-3 s | Contactors & Overload Relays | View details |
| Schneider Electric LADR2 TeSys D Off-Delay Timer Block 1-30 s | Contactors & Overload Relays | You are viewing this model |
| Schneider Electric LADS2 TeSys D On-Delay Timer Block 1-30 s | Contactors & Overload Relays | View details |
| Schneider Electric LADT2 TeSys Deca On-Delay Timer Block 1-30 s | Contactors & Overload Relays | View details |
Datasheets & Documents
- Datasheet Schneider Electric LADR2 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LADR2 TeSys D Off-Delay Timer
Answers from our engineering team on installation, compatibility and integration.
01What is the delay range of the LADR2?
1 to 30 seconds. See the datasheet linked on this page for the full figures.
02Is the LADR2 an on-delay or off-delay block?
Off delay. See the datasheet linked on this page for the full figures.
03What contact arrangement does the LADR2 have?
1 NO + 1 NC. Check that this arrangement matches your control circuit before ordering.
04What current rating applies?
6 A at 120 V AC-15, 10 A thermal. See the datasheet linked on this page for the full figures.
05What is the mechanical durability?
5 Mcycles. See the datasheet linked on this page for the full figures.