Schneider Electric LADN40 TeSys D 4 NO Front Contact Block
Description
LADN40: four normally open contacts in one TeSys D front block
The LADN40 is a Schneider Electric TeSys D front auxiliary contact block with four normally open contacts. It suits a contactor whose job is to start or signal many things at once and which has no interlock role. Seven Star LLC supplies the LADN40 in Oman and the GCC as an independent supplier based in Muscat.
The reference 40 reads four NO, no NC. The datasheet lists the block with IP2X protection, 44 mm width and screw clamp terminals, making it the all-closing counterpart of the LADN22 and LADN31.
Technical specifications of the LADN40
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / LADN40 |
| Description | Product datasheet Auxiliary contact block, TeSys D, 4NO, front mounting, screw clamp terminals |
| Range | TeSys; TeSys Deca |
| Product name | TeSys Deca |
| Product or component type | Auxiliary contact block |
| Device short name | LADN |
| Range compatibility | TeSys D CAD; TeSys D LC1D; TeSys F LC1F; TeSys F CR1F; TeSys Deca CAD; TeSys Deca LC1D |
| Mounting location | Front |
| Pole contact composition | 4 NO |
| Contacts operation | Instantaneous |
| [Ue] rated operational voltage | 690 V AC 25 to 400 Hz |
| [Ie] rated operational current | 6 A at 120 V AC-15; 1.04 A at 690 V AC-15; 0.55 A at 125 V DC-13; 0.1 A at 600 V DC-13 |
| [Ui] rated insulation voltage | 690 V conforming to IEC 60947-5-1; 600 V conforming to UL; 600 V conforming to CSA |
| [Ith] conventional free air thermal | 10 A (at 60 °C) |
| Standards | EN/IEC 60947-5-1; GB/T 14048.5; EN 50012; UL 60947-5-1; CSA C22.2 No 60947-5-1; IEC 60335-1:Clause 30.2; IEC 60335-2-40:Annex JJ; UL 60335-2-40:Annex JJ |
| Product certifications | CB Scheme; UL; CSA; CCC; EAC; UKCA |
| Irms rated making capacity | 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1 |
| Permissible short-time rating | 100 A 60 °C 1 s; 120 A 60 °C 500 ms; 140 A 60 °C 100 ms; are subject to change – check with your local distributor. |
| Protection type | GG fuse 10 A |
| Mechanical durability | 30 Mcycles |
| Minimum switching current | 5 mA |
| Minimum switching voltage | 17 V |
| Non-overlap time | 1.5 ms on de-energisation no overlap between NC and NO contact; 1.5 ms on energisation no overlap between NC and NO contact |
| Insulation resistance | > 10 MOhm |
| Connections – terminals | Screw clamp terminals 1 cable(s) 1 to 4 mm²flexible with cable end; Screw clamp terminals 1 cable(s) 1 to 4 mm²flexible without cable end |
| Height | 48 mm |
| Width | 44 mm |
| Depth | 42 mm |
| Net weight | 0.05 kg |
| Environmental characteristic | Normal environment |
| IP degree of protection | IP2X conforming to IEC 60529 |
| Ambient air temperature (operation, as listed) | -5 to 60 °C |
| Operating altitude | 3000 m |
LADN40 electrical details
Rated operational voltage is 690 V AC at 25 to 400 Hz, with conventional thermal current of 10 A at 60 °C. Rated operational current is 6 A at 120 V AC-15, 1.04 A at 690 V AC-15, 0.55 A at 125 V DC-13 and 0.1 A at 600 V DC-13. Making capacity is 140 A AC and 250 A DC, protection is a 10 A gG fuse, mechanical durability is 30 Mcycles, and the minimum switching level is 5 mA at 17 V. The non-overlap time between the NC and NO contacts is 1.5 ms on energisation and on de-energisation.
Compatibility is the same as other front blocks: TeSys D and Deca LC1D and CAD, TeSys F LC1F and CR1F. The block is 44 mm wide, 48 mm high and 42 mm deep.
LADN family: the LADN40 compared with its siblings
All six references below are front-mounting TeSys D blocks with screw clamp terminals; they differ in contact pattern and width.
| Reference | Contacts | Width | Protection |
|---|---|---|---|
| LADN11 | 1 NO + 1 NC | 26 mm | IP20 conforming to IEC 60529 |
| LADN11G | 1 NO + 1 NC | 26 mm | IP20 conforming to IEC 60529 |
| LADN20 | 2 NO | 26 mm | IP20 conforming to IEC 60529 |
| LADN22 | 2 NO + 2 NC | 44 mm | IP20 conforming to IEC 60529 |
| LADN31 | 3 NO + 1 NC | 44 mm | IP2X conforming to IEC 60529 |
| LADN40 | 4 NO | 44 mm | IP2X conforming to IEC 60529 |
Four closing contacts in the LADN40
A single contactor can feed four independent circuits: a seal-in, a run lamp, a PLC feedback and a sequence start. Because all contacts are normally open, they close together with the contactor and are open whenever the coil is off.
If the scheme needs a lockout, add a block with NC contacts. The LADN40 is for signal-heavy schemes.
LADN40 wiring and verification
Plan wiring for eight terminals with ferrules. Torque 1.7 N.m. Check the four contacts close together when the contactor is operated manually.
Where circuits at different voltages share the block, separate the wires with sleeves and note the voltages on the schematic.
LADN40 selection checklist
- Four NO contacts.
- Four separate circuits should be at compatible voltages, or physically segregated in the cabinet.
- Width: 44 mm.
- Contactor type from the datasheet list.
- Protection: IP2X per the datasheet.
LADN40 uses in Oman and the GCC
Large ventilation systems, pump halls and conveyor lines use contactors that start the next stage of the sequence. The LADN40 provides several such commands from the main contactor at once.
Equally it suits skids that must report status to a PLC, a local panel, a fire system interface and a counter at the same time.
Information to send with an RFQ for the LADN40
- Full reference and quantity required
- Contactor model the block mounts on
- Contact arrangement needed (NO and NC count)
- Control voltage and load of each circuit
- Delivery location and timing
Storage, handling and spares for the LADN40
Keep the LADN40 in its original packaging in a dry, dust-free store until installation, and check the label against the order before fitting. For plants that run continuously, holding one spare unit on site shortens downtime if a replacement is needed during a shutdown or after a fault. Record the reference and installation date in the maintenance log so the next order can be placed quickly.
Documents and quotation
A datasheet for the LADN40 is attached on this page. It carries the electrical, mechanical and environmental data summarised above, so the figures can be checked against your drawings.
Send the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Tesys D Ladn Range
Seven Star LLC supplies models from the Se Tesys D Ladn range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric LADN11 TeSys D 1 NO + 1 NC Contact Block | Contactors & Overload Relays | View details |
| Schneider Electric LADN11G TeSys D 1 NO + 1 NC EN 50012 Block | Contactors & Overload Relays | View details |
| Schneider Electric LADN20 TeSys D 2 NO Front Contact Block | Contactors & Overload Relays | View details |
| Schneider Electric LADN22 TeSys D 2 NO + 2 NC Contact Block | Contactors & Overload Relays | View details |
| Schneider Electric LADN31 TeSys D 3 NO + 1 NC Contact Block | Contactors & Overload Relays | View details |
| Schneider Electric LADN40 TeSys D 4 NO Front Contact Block | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric LADN40 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric LADN40 TeSys D 4 NO Front
Answers from our engineering team on installation, compatibility and integration.
01What contacts does the LADN40 have?
Four normally open contacts. Check that this arrangement matches your control circuit before ordering.
02What is the width of the LADN40?
44 mm. See the datasheet linked on this page for the full figures.
03Which protection class is listed?
IP2X per IEC 60529. See the datasheet linked on this page for the full figures.
04What conductor range is listed?
1 to 4 mm2 flexible with cable end for a single conductor.
05What is the certification list?
CB Scheme, UL, CSA, CCC, EAC and UKCA. See the datasheet linked on this page for the full figures.