Brand: Schneider Electric
Schneider Electric CAD32D7 TeSys D Relay 3NO+2NC 42V AC
Description
CAD32D7 TeSys D control relay: what the part number tells you
The CAD32D7 is a Schneider Electric TeSys D control relay: TeSys D control relay, 3 NO + 2 NC, up to 690 V, 42 V AC standard coil. In plain terms it is a contactor-style relay with three normally open and two normally closed contacts, designed for control circuits rather than motor power, and its coil is rated 42 V AC 50/60 Hz. Seven Star LLC supplies the CAD32D7 in Oman and the GCC as an independent supplier based in Muscat.
Reading the code against the datasheet: CAD is the TeSys D control relay series, 32 gives the 3 NO + 2 NC contact arrangement (five poles in both cases), and the ending D7 stands for the 42 V AC 50/60 Hz coil that the datasheet lists for this reference. Neighbouring references differ only in the coil voltage or type, so the complete code decides whether the relay will fit your control supply.
Technical specifications of the CAD32D7
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / CAD32D7 |
| Range / type | TeSys Deca control relay (TeSys CAD) |
| Pole contact composition | 3 NO + 2 NC |
| Utilisation categories | AC-15; AC-14; DC-13 |
| Rated operational voltage (Ue) | ≤ 690 V AC 25 to 400 Hz |
| Control circuit voltage (Uc) | 42 V AC 50/60 Hz |
| Control voltage limits | 0.3 to 0.6 Uc (-40 to 70 °C):drop-out AC 50/60 Hz; 0.8 to 1.1 Uc (-40 to 60 °C):operational AC 50 Hz; 0.85 to 1.1 Uc (-40 to 60 °C):operational AC 60 Hz; 1 to 1.1 Uc (60 to 70 °C):operational AC 50/60 Hz |
| Operating time | 12 to 22 ms coil energisation and NO closing; 4 to 12 ms coil de-energisation and NO opening; 4 to 19 ms coil energisation and NC opening; 6 to 17 ms coil de-energisation and NC closing |
| Inrush / hold-in power | 70 VA 50 Hz (at 20 °C) / 8 VA 50 Hz (at 20 °C) |
| Thermal current (Ith) | 10 A (at 60 °C) |
| Rated making capacity | 140 A AC conforming to IEC 60947-5-1; 250 A DC conforming to IEC 60947-5-1 |
| Associated fuse | 10 A gG conforming to IEC 60947-5-1 |
| Insulation voltage (Ui) | 690 V IEC 60947-5-1; 600 V UL and CSA |
| Mechanical durability / rate | 30 Mcycles / 180 cyc/mn |
| Mounting / terminals | DIN rail or plate; screw clamp 1 to 4 mm², 1.7 N.m |
| Dimensions (H x W x D) | 77 mm x 45 mm x 84 mm |
| Net weight | 0.58 kg |
| Degree of protection | IP2X front face conforming to VDE 0106 |
| Ambient temperature, operation | -40 to 60 °C; 60 to 70 °C with derating |
| Ambient temperature, storage | -60 to 80 °C |
| Certifications | CB; CCC; UL; CSA; EAC; CE; UKCA |
Coil, operating window and supply sizing for the CAD32D7
The coil is the one part that distinguishes the CAD32D7 from its siblings, so it deserves the closest reading.
The 42 V AC coil is a less common voltage, found on machines and cabinets built around a 42 V control winding, for instance imported equipment wired to European or Asian machine-tool practice. It keeps the control circuit in the extra-low-voltage range while giving a lower current than a 24 V coil. With 70 VA inrush and 8 VA hold-in at 50 Hz, the coil draws about 1.7 A at pull-in and 0.19 A when held in.
The operating window of 0.8 to 1.1 Uc at 50 Hz is about 33.6 to 46.2 V and, at 60 Hz, 35.7 to 46.2 V. The drop-out band of 0.3 to 0.6 Uc is about 12.6 to 25.2 V. Because 42 V is not a standard supply in most Omani panels, this reference is nearly always a like-for-like replacement for an existing relay in imported machinery, and the nameplate of the old relay is the best proof that 42 V is really what the control transformer delivers.
Calculated from the datasheet, the 42 V AC 50/60 Hz coil of the CAD32D7 has an operational window of 33.6 to 46.2 V at 50 Hz (0.8 to 1.1 Uc), from 35.7 V at 60 Hz, and it drops out at 12.6 to 25.2 V (0.3 to 0.6 Uc). The datasheet gives 70 VA inrush and 8 VA hold-in at 50 Hz, which corresponds to about 1.67 A at pull-in and 190 mA when held in at the nominal voltage. These are indicative figures worked out from the stated power and voltage, and they are meant for supply sizing, not as guaranteed current ratings.
Contact arrangement of the CAD32D7: three normally open and two normally closed contacts
The 3 NO + 2 NC configuration is the most flexible arrangement for a control relay, because the normally closed pair lets one device take part in interlocking and fault-reset circuits as well as repeating a signal. The datasheet lists a non-overlap time of 1.5 ms on energisation and 1.5 ms on de-energisation between the normally closed and normally open contacts, so that the two groups do not conduct at the same time during a transition.
Use the normally closed contacts for permissive and interlock loops that must fall away on operation, such as stopping a second starter while the first is running, or for a healthy-state signal that drops out when the relay operates. The normally open contacts are available to repeat start, run and trip signals. If a circuit needs more than three normally open contacts and no normally closed ones, the 5 NO version of the same family is the better match.
Contact data from the datasheet apply to all five poles: 10 A conventional thermal current at 60 °C, utilisation categories AC-15, AC-14 and DC-13, a rated operational voltage up to 690 V AC, and a minimum switching capability of 17 V and 5 mA, which makes the contacts suitable for low-level signals as well as for 24 V PLC inputs.
Where the CAD32D7 sits in the CAD32 family
The CAD32D7 is one member of a family of TeSys D control relays that share the housing, the contact data and the mounting. Only the coil voltage and type change from one reference to the next, together with the contact arrangement: the CAD32 series is 3 NO + 2 NC and the CAD50 series is 5 NO. The table lists the CAD32 references we are asked for most.
If the supply is not in the table, ask us; the CAD50 series has the other contact arrangement. AC-coil versions are 84 mm deep and DC-coil versions 93 mm, which matters in a shallow enclosure.
| Reference | Coil voltage and type | Contacts |
|---|---|---|
| CAD32BD | 24 V DC standard | 3 NO + 2 NC |
| CAD32BL | 24 V DC low consumption | 3 NO + 2 NC |
| CAD32D7 (this page) | 42 V AC 50/60 Hz | 3 NO + 2 NC |
| CAD32ED | 48 V DC standard | 3 NO + 2 NC |
| CAD32F7 | 110 V AC 50/60 Hz | 3 NO + 2 NC |
| CAD32FD | 110 V DC standard | 3 NO + 2 NC |
| CAD32JD | 12 V DC standard | 3 NO + 2 NC |
| CAD32M7 | 220 V AC 50/60 Hz | 3 NO + 2 NC |
| CAD32MD | 220 V DC standard | 3 NO + 2 NC |
| CAD32N7 | 415 V AC 50/60 Hz | 3 NO + 2 NC |
| CAD32R7 | 440 V AC 50/60 Hz | 3 NO + 2 NC |
| CAD32U7 | 240 V AC 50/60 Hz | 3 NO + 2 NC |
| CAD32V7 | 400 V AC 50/60 Hz | 3 NO + 2 NC |
Selection checklist for the CAD32D7
- Coil: 42 V AC 50/60 Hz, confirmed from the supply drawing or the nameplate of the relay being replaced.
- Contacts: three normally open and two normally closed contacts, matched to the interlock and signalling circuits.
- Supply sizing: about 1.67 A at pull-in and 190 mA held in (derived from the datasheet power).
- Window: operates within 33.6 to 46.2 V at 50 Hz (0.8 to 1.1 Uc), from 35.7 V at 60 Hz and releases at 12.6 to 25.2 V (0.3 to 0.6 Uc).
- Contact load of the CAD32D7: 10 A thermal, AC-15, AC-14 or DC-13 duties; use a contactor for motor-power loads.
- Space: 77 mm high, 45 mm wide and 84 mm deep.
- Environment: operation up to 60 °C, up to 70 °C with derating; storage -60 to 80 °C.
- Type: AC and DC coils of the same voltage are different references; do not mix them.
Mounting, wiring and service life of the CAD32D7
Mount the CAD32D7 on a 35 mm DIN rail or on a plate; the datasheet lists both. It measures 77 mm x 45 mm x 84 mm and weighs 0.58 kg, so allow space for the wires to bend at the terminals and for air to circulate around the housing. Tighten the screw-clamp terminals to 1.7 N.m with a Philips No 2, Pozidriv No 2 or 6 mm flat screwdriver, and do not exceed the cable sizes of 1 to 4 mm² per terminal listed in the datasheet.
Commissioning is simple: energise the coil at nominal voltage, verify that all five poles move together, and check the contact action with a meter before connecting the field loads. The mechanical durability is 30 million cycles and the maximum operating rate is 180 cycles per minute, so in normal control duty there is no routine wear item to schedule. In a dusty site, clean the panel and check terminal tightness during planned shutdowns, because loose terminals, more often than the relay itself, cause intermittent faults.
Where the CAD32D7 is used in Oman and the GCC
Low-voltage AC coils are used where a control transformer separates the relay circuit from the mains. In the GCC they appear mostly in machine panels, HVAC and pump control cabinets built by international manufacturers, where a 24, 42 or 48 V winding supplies relays, pilot lamps and solenoid valves. Here the relay is a repeater and interlock element between a controller output and field loads or drives.
For the CAD32D7, that means three normally open and two normally closed contacts from one 42 V AC 50/60 Hz command, sitting next to LC1D contactors of the same TeSys D family on the same rail.
Information to send with an RFQ for the CAD32D7
- Full reference CAD32D7 and the quantity
- The coil voltage and type seen on the supply drawing or on the old relay nameplate
- The load or circuit each contact will switch (voltage, current, signal level)
- Panel or machine the relay must fit, and whether it is a spare, a replacement or a new installation
- Delivery location in Oman or the GCC and the date required
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above, and it is worth reading beside the panel drawing before you order.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.
Other Models in the Se Cad32 Range
Seven Star LLC supplies models from the Se Cad32 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric CAD32BD TeSys D Relay 3NO+2NC 24V DC | Contactors & Overload Relays | View details |
| Schneider Electric CAD32BL TeSys D Relay 3NO+2NC 24VDC Low Power | Contactors & Overload Relays | View details |
| Schneider Electric CAD32D7 TeSys D Relay 3NO+2NC 42V AC | Contactors & Overload Relays | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric CAD32D7 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric CAD32D7 TeSys D Relay 3NO+2NC
Answers from our engineering team on installation, compatibility and integration.
01What coil does the CAD32D7 have?
The datasheet lists a 42 V AC 50/60 Hz AC 50/60 Hz coil. The operational window is 33.6 to 46.2 V at 50 Hz and drop-out is 12.6 to 25.2 V.
02How many contacts does the CAD32D7 have?
It has three normally open and two normally closed contacts, with a 10 A conventional thermal current at 60 °C and utilisation categories AC-15, AC-14 and DC-13.
03How much power does the coil of the CAD32D7 draw?
The datasheet gives 70 VA inrush and 8 VA hold-in at 50 Hz. At 42 V that is about 1.67 A at pull-in and 190 mA held in, derived from the stated power.
04What are the dimensions and weight of the CAD32D7?
77 mm high, 45 mm wide and 84 mm deep, with a net weight of 0.58 kg. It mounts on a DIN rail or a plate.
05What ambient temperature does the CAD32D7 accept?
Operation is listed from -40 to 60 °C, and up to 70 °C with derating; storage is -60 to 80 °C. Altitude is 0 to 3000 m.


















Reviews
There are no reviews yet.