Brand: DAB Pumps
DAB K 35/40 M Twin-Impeller Centrifugal Pump 0.75 kW
Description
K 35/40 M is the smallest single-phase model in the DAB K twin-impeller range: a 0.75 kW (1 HP) horizontal centrifugal pump with a cast-iron body, two technopolymer impellers, a 6 bar pressure limit and a tabulated head of 43.5 m at zero flow.
Twin impellers for pressurisation and tank filling
DAB designed the K twin-impeller series for water pressurisation units and for filling pressure vessels, and also lists sprinkler systems and general water supply as suitable uses.
The K 35/40 M sits at the lower end of the family, which the datasheet describes as 1.2 to 30 m3/h with heads up to 97 m across all models. For this code the tabulated curve runs from 43.5 m at zero flow to 23.5 m at 4.8 m3/h.
Construction as printed on the sheet
- Pump body and motor support in cast iron 200 UNI ISO 185, with a cast-iron intermediate disc.
- Technopolymer A impellers; shaft with rotor in AISI 416 stainless steel (X12CrS13) for the K 35/40.
- Carbon/ceramic mechanical seal and NBR rubber gasket.
- Closed asynchronous motor with external ventilation, oversized permanently lubricated ball bearings and built-in thermo-amperometric protection.
- Capacitor permanently fitted on single-phase versions; IE2 motors as standard from 0.75 kW.
- Construction according to CEI 2-3, as printed.
Technical specification
Operating limits (K 35/40)
| Parameter | Specification |
|---|---|
| Pumped liquid | Clean, free of solids and abrasives, non-viscous, non-aggressive, non-crystallised, chemically neutral |
| Liquid temperature | -10°C to +50°C |
| Maximum ambient temperature | +40°C |
| Maximum operating pressure | 6 bar (600 kPa) |
| Motor protection | IP 44 (K 35/40); IP 55 at the terminal board |
| Insulation class | F |
| Installation | Fixed, horizontal or vertical, with the motor always above the pump |
K 35/40 M electrical and hydraulic data
| Parameter | Specification |
|---|---|
| Supply | 1 x 220-240 V ~, 50 Hz |
| P1 max | 1.2 kW |
| P2 nominal | 0.75 kW (1 HP) |
| Rated current / starting current | 5.5 A / 20 A |
| Speed | 2800 rpm |
| Capacitor | 20 µF, 450 V |
| Head at 0 / 1.2 / 1.8 m3/h | 43.5 m / 41.5 m / 40 m |
| Head at 2.4 / 3.6 / 4.8 m3/h | 38 m / 33 m / 23.5 m |
Dimensions and weight (K 35/40 M)
| Parameter | Specification |
|---|---|
| A / B / C / D | 342 / 180 / 76 / 148 mm |
| E / F / G / hole diameter | 72 / 15 / 148 mm / 9.5 mm |
| H / H1 / H2 | 235 / 100 / 135 mm |
| Ports (DNA / DNM) | 1 inch G / 1 inch G |
| Packing | 392 x 232 x 262 mm, 0.024 m3 |
| Gross weight | 15.9 kg |
Order code and neighbouring models
The sheet lists the K 35/40, 45/50, 55/50, 35/100, 40/100, 55/100, 66/100, 90/100, 70/300, 80/300, 70/400 and 80/400. The K 35/40 is offered as M (single-phase) and T (three-phase 230/400 V, in IE3 and IE2 motor versions). Only the 70/300 to 80/400 models are rated for liquids up to +110°C, so they are different items from this one. If your system needs more than about 4.8 m3/h or more than 43 m, look at the K 45/50 or K 55/50 rather than oversizing this code.
Installation notes
The motor must stay above the pump whether you mount it horizontally or vertically. The 1 inch G ports are threaded, so union fittings or a short flexible hose on each side make removal easy. Fit a pressure vessel and a pressure switch or controller on the delivery side for a booster duty; the sheet does not supply them. IP 44 protects against splashes only, so keep the motor out of the weather.
Uses in Oman and the GCC
Small booster sets for villas, farm buildings and site offices, filling of overhead or pressure tanks, and basic irrigation or sprinkler feed from a storage tank are the natural fits. The 6 bar limit and IP 44 motor make it a clean-water pump for indoor or sheltered locations rather than an exposed outdoor industrial one; the sheet gives no corrosion or dust rating.
Selection and installation notes
A pump is selected from the duty point: the flow and the head the system needs, with the curve on the data sheet checked at that point. Confirm the liquid, its temperature and any solids, the electrical supply and the connection sizes, fit isolating valves and a non-return valve where the system needs them, protect the motor with a suitable overload device and prime the pump before running it. Do not run it dry or against a closed discharge.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related DAB items
For automatic pressure control look at DAB electronic pressure controllers and the Esybox line in the same catalogue; the K 35/40 M sheet itself covers only the pump. See other models in the Pumps category.
Related DAB Pumps products: DAB JET 102 M Self-Priming Centrifugal Pump 0.75 kW, DAB KLP 50-1200 T In-Line Circulating Pump DN50 0.72 kW, DAB MICRA 100 M 3-Inch Multi-Impeller Submersible Pump, DAB KDN 50-160 Standardised End-Suction Centrifugal Pump, DAB S4 8/9 4-Inch Submersible Borehole Pump 1.5 kW and DAB DRENAG 1000 M Stainless Steel Submersible Drainage Pump.
Documents and quotation
Download the official DAB Pumps technical data sheet for K 35/40 M from this page. As an independent supplier based in Muscat, Seven Star LLC supplies DAB Pumps items on request: use the quote form with the quantity you need. Check every value in the document against your own specification before you order. Browse similar items in the category.
Datasheets & Documents
- Datasheet DAB K twin-impeller technical sheet (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
DAB Pumps is an Italian manufacturer of pumps for water supply, heating and drainage, whose brand was born in 1975 in the Veneto region; it is headquartered in Mestrino, near Padua. DAB joined the Grundfos group in 1996 while keeping its own business direction, and later added brands such as Alma, Leader Pumps and Brisan. The company reports about 2.3 million pumps produced a year.
Seven Star LLC is an independent supplier in Muscat. We list DAB pumps and booster sets for homes, buildings and contractors in Oman and the GCC.
DAB Pumps company profile
| Founded | 1975, Veneto, Italy |
|---|---|
| Headquarters | Mestrino, Padua, Italy |
| Ownership | Grundfos group, since 1996 |
| Scale | About 1,750 people and 2.3 million pumps a year (2024) |
| Product families | E.SYBOX pressure boosting systems, EVOPLUS circulators, K and KV multistage pumps, JET self-priming pumps, NOVA and FEKA drainage and sewage pumps, S4 submersible borehole pumps, booster sets |
Milestones
- 1975: The DAB brand is born.
- 1996: DAB becomes part of the Grundfos group.
- 2025: DAB marks 50 years.
DAB product series
Boosting pumps include the ESYBOX MINI 3 electronic pressure booster and the 2NKV 10/8 T twin-pump booster set with two 3 kW pumps. Surface pumps include the JET 102 M self-priming pump, the K 35/40 M twin-impeller pump, the KDN 50-160 standardised end-suction pump and the KLP 50-1200 T in-line circulator.
Submersible pumps include the S4 8/9 4-inch borehole pump, the MICRA 100 M 3-inch multi-impeller pump, the DRENAG 1000 M stainless drainage pump and the FEKA VS GRINDER 1000 MA sewage pump with shredder.
Where DAB pumps are used
Water pressure in villas and buildings, tank transfer, wells and boreholes, heating and cooling circulation, garden irrigation, and drainage and sewage lifting.
DAB Pumps products we list
Ordering DAB pumps: what we need
Send the model, or the flow, head and liquid, the power supply (single or three-phase) and the installation, such as a tank, well size or sump.
Facts checked against DAB's own company pages (dabpumps.com) and trade press, October 2026.
Browse DAB Pumps products by category: Pumps.
FAQ
Questions about the DAB K 35/40 M Twin-Impeller Centrifugal Pump 0.75 kW
Answers from our engineering team on installation, compatibility and integration.
01What is the maximum pressure of the K 35/40 M?
6 bar (600 kPa), as printed for the K 35/40, K 35/100 and K 40/100.
02What liquid temperature can it handle?
From -10°C to +50°C for this model; the K 70/300 to 80/400 models go to +110°C.
03What is the head at 3.6 m3/h?
The selection table gives 33 m at 3.6 m3/h and 43.5 m at zero flow.
04Can it run in a vertical position?
Yes, horizontal or vertical, provided the motor is always above the pump.
05Does Seven Star LLC act as a DAB Pumps distributor?
No, we are an independent supplier in Muscat and supply DAB Pumps items on request rather than acting as a DAB Pumps channel partner.