- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- HMI Displays
- Motor Soft Starters
- Isolator & Barrier
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: DAB Pumps
DAB 2NKV 10/8 T Twin-Pump Pressure Booster Set 2 x 3 kW
Description
2NKV 10/8 T is a DAB constant-pressure booster set built from two vertical multistage NKV 10 pumps with eight stages each, 3 kW per pump on 3 x 400 V, a combined maximum flow of 26 m3/h and a maximum obtainable pressure of 8 bar, assembled on a galvanised steel base.
A ready-assembled duty/assist booster for buildings and industry
DAB designs the NKV sets for constant-pressure supply in water pipelines, irrigation, industry, hotels, residential buildings and spas. The idea, as the sheet explains, is that inverter-driven pumps adapt their performance curve to demand, holding pressure steady as the flow changes instead of cycling a fixed-speed pump.
The 2NKV 10/8 T uses two pumps working together; the sheet states the plotted performance is for both pumps running at the same time. Each pump is rated 3 kW (4 HP) and draws 5.8 A, the set can reach 8 bar and the standard pressure setting listed is 7.0 bar.
What is supplied on the set
- Two vertical multistage pumps on a galvanised steel base, tested and ready for installation.
- Isolator and check valve on each pump, suction and delivery manifolds, expansion vessels, pressure sensor and on-pump inverter.
- Protection control unit; an optional flow sensor is possible for pressure control.
- IP 54 metal control panel on the base with AUT-0-MAN selectors and operation notification lamps.
- Protection against abnormal voltage, dry run (without minimum manometer), phase short circuit, overtemperature, overvoltage, pressure sensor fault, plus anti-seizing and anti-freeze functions.
- IE2 motors as standard from 0.75 kW to 5.5 kW, IE3 from 7.5 kW.
Technical specification
Range data (1-2-3-4 NKV sets)
| Parameter | Specification |
|---|---|
| Operating range of the range | 4 to 280 m3/h |
| Pumped liquid | Clean, free from solids |
| Liquid temperature (NKV 10 page) | -15 to +80°C |
| Maximum ambient temperature | +40°C |
| Maximum pressure of the range | 14 bar |
| Pressure regulation range | 3 to 14 bar |
| Protection class | IP 55 |
| Installation | Vertical only |
| Line and pump voltage | 400 V three-phase, 50-60 Hz |
2NKV 10/8 T electrical and hydraulic data
| Parameter | Specification |
|---|---|
| Supply | 3 x 400 V ~ |
| Power per pump P2 | 3 kW (4 HP) |
| Current per pump | 5.8 A |
| Maximum obtainable pressure | 8 bar |
| Standard pressure | 7.0 bar |
| Maximum flow, two pumps | 26 m3/h |
| Pumps in set | 2 (NKV 10 pumps, 8 stages) |
Dimensions and weight (2 NKV 10)
| Parameter | Specification |
|---|---|
| A / B / C / D | 1120 / 820 / 800 / 860 mm |
| E / F / G | 110 / 790 / 80 mm |
| H / H1 | 1525 / 226 mm |
| Suction and delivery connections (DNA / DNM) | 2 1/2 inch / 2 1/2 inch |
| Weight | 123 kg |
Reading the code and choosing a variant
The code reads 2 pumps, NKV 10 pump series, 8 stages (derived from the curve labels 10/5 to 10/14 on the sheet) and T for three-phase. Sibling codes in the same table run from 2NKV 10/5 T (2 x 2.2 kW, 5 bar) to 2NKV 10/14 T (2 x 5.5 kW, 14 bar), so the 10/8 T sits in the middle: choose it when roughly 7 bar of standard pressure and up to 26 m3/h are enough. For more flow, the sheet also lists the 2 NKV 15 set and larger NKV series, as well as 1, 3 and 4 pump arrangements.
Installation notes
The set is installed vertically on its base in a plant room with the supply of 3 x 400 V, 50 or 60 Hz. Keep ambient temperature below 40°C and the water free of solids. The panel is IP 54 and the pumps are IP 55 as printed, so keep the plant room dry and ventilated. The control panel starts motors directly up to 7.5 kW and star-delta above that.
Duties across Oman and the GCC
Hotels, apartment towers, hospitals, labour camps and factory utilities that draw water from a ground tank and must hold constant pressure to upper floors are the target. A two-pump set lets the pumps share the load, but the sheet does not describe alternation or standby logic, so confirm with the manufacturer how the pumps are sequenced for your system.
A booster set is selected from the peak demand, the required pressure and the supply pressure at the inlet. Fit it on a level base with isolating valves on both sides and flexible connectors to reduce vibration, protect the supply with a suction pressure switch where the inlet can fail, check the vessel pre-charge and set the pressure to match the highest outlet in the building.
Information needed for a quotation
Send the full model code, the quantity, the delivery location in Oman or the GCC, the intended use and any accessories needed, so that the complete package can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification and the site risk assessment before a purchase is confirmed. Ratings, standards and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Related DAB items
The same sheet covers 1 NKV single-pump sets and 3 NKV and 4 NKV multi-pump sets, and DAB lists NKVE sets with MCE/P drives, E.BOX versions and EN 12845 sets in the catalogue. See other DAB pumps in the Pumps category.
Frequently asked questions
What does 2NKV 10/8 T mean?
Two NKV 10 pumps with eight stages (derived from the curve labels), three-phase 400 V; the sheet lists the set at 2 x 3 kW.
What pressure can the set reach?
The datasheet lists a maximum obtainable pressure of 8 bar and a standard pressure of 7.0 bar for this code.
What is the combined flow?
The NKV 10 two-pump page gives a maximum flow of 26 m3/h.
Is an inverter included?
Yes, the sheet lists an on-pump inverter, pressure sensor and protection control unit in the set.
Is Seven Star LLC a DAB Pumps distributor?
No. Seven Star LLC is an independent supplier in Muscat that sources DAB Pumps products on request.
Documents and quotation
Download the official DAB Pumps technical data sheet for 2NKV 10/8 T from this page. As an independent supplier based in Muscat, Seven Star LLC supplies DAB Pumps items on request: use the quote form with the quantity you need. Check every value in the document against your own specification before you order. Browse similar items in the category.
Datasheets & Documents
- Datasheet DAB 1-2-3-4 NKV technical sheet (PDF) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
DAB Pumps is an Italian manufacturer of pumps for water supply, heating and drainage, whose brand was born in 1975 in the Veneto region; it is headquartered in Mestrino, near Padua. DAB joined the Grundfos group in 1996 while keeping its own business direction, and later added brands such as Alma, Leader Pumps and Brisan. The company reports about 2.3 million pumps produced a year.
Seven Star LLC is an independent supplier in Muscat. We list DAB pumps and booster sets for homes, buildings and contractors in Oman and the GCC.
DAB Pumps company profile
| Founded | 1975, Veneto, Italy |
|---|---|
| Headquarters | Mestrino, Padua, Italy |
| Ownership | Grundfos group, since 1996 |
| Scale | About 1,750 people and 2.3 million pumps a year (2024) |
| Product families | E.SYBOX pressure boosting systems, EVOPLUS circulators, K and KV multistage pumps, JET self-priming pumps, NOVA and FEKA drainage and sewage pumps, S4 submersible borehole pumps, booster sets |
Milestones
- 1975: The DAB brand is born.
- 1996: DAB becomes part of the Grundfos group.
- 2025: DAB marks 50 years.
DAB product series
Boosting pumps include the ESYBOX MINI 3 electronic pressure booster and the 2NKV 10/8 T twin-pump booster set with two 3 kW pumps. Surface pumps include the JET 102 M self-priming pump, the K 35/40 M twin-impeller pump, the KDN 50-160 standardised end-suction pump and the KLP 50-1200 T in-line circulator.
Submersible pumps include the S4 8/9 4-inch borehole pump, the MICRA 100 M 3-inch multi-impeller pump, the DRENAG 1000 M stainless drainage pump and the FEKA VS GRINDER 1000 MA sewage pump with shredder.
Where DAB pumps are used
Water pressure in villas and buildings, tank transfer, wells and boreholes, heating and cooling circulation, garden irrigation, and drainage and sewage lifting.
DAB Pumps products we list
Ordering DAB pumps: what we need
Send the model, or the flow, head and liquid, the power supply (single or three-phase) and the installation, such as a tank, well size or sump.
Facts checked against DAB's own company pages (dabpumps.com) and trade press, October 2026.
Browse DAB Pumps products by category: Pumps.
Related products
Frequently Asked Questions
Two NKV 10 pumps with eight stages (derived from the curve labels), three-phase 400 V; the sheet lists the set at 2 x 3 kW.
The datasheet lists a maximum obtainable pressure of 8 bar and a standard pressure of 7.0 bar for this code.
The NKV 10 two-pump page gives a maximum flow of 26 m3/h.
Yes, the sheet lists an on-pump inverter, pressure sensor and protection control unit in the set.
No. Seven Star LLC is an independent supplier in Muscat that sources DAB Pumps products on request.

Reviews
There are no reviews yet.