- Automation & ControlView all 1,843 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Servo Drives
- Motor Soft Starters
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: KROHNE
KROHNE OPTIMASS 7400 Straight-Tube Coriolis Mass Flowmeter
Description
High-end Coriolis meter for demanding process media and custody transfer
The KROHNE OPTIMASS 7400 is a high-end Coriolis mass flowmeter with a single straight measuring tube. KROHNE positions it for challenging process media and custody transfer, including gases, shear-sensitive or viscous liquids, slurries and very aggressive chemicals. Mass, density and volume flow are measured with +/-0.1 percent of measured value, and the meter holds the highest OIML accuracy class of 0.3 for custody transfer. The Entrained Gas Management function keeps the meter running when air or gas bubbles pass through a liquid, and Bluetooth gives a secure wireless link for commissioning, verification and diagnostics within about 20 m.
Four sensor materials are listed: titanium, duplex stainless steel, Alloy 22 and tantalum, which lets one family handle acids, chlorides and other corrosive liquids. A food and beverage version is also listed, and hygienic approvals on the page include FDA, 3A, EHEDG, EC 1935/2004 and ASME BPE. Ex approvals cover ATEX, IECEx, NEPSI, EAC Ex, cFMus, INMETRO, KCs and UKEX.
Technical specifications
| Parameter | Specification |
|---|---|
| Model | OPTIMASS 7400 (sensor OPTIMASS 7000 type; MFC 400 converter) |
| Principle | Coriolis, single straight tube |
| Measured values | Mass, density, temperature; calculated volume and concentration |
| Accuracy | +/-0.1 % of measured value (mass, density, volume); OIML class 0.3 for custody transfer |
| Flange sizes | EN 1092-1 DN10 to DN100; ASME 1/2 to 4 in; JIS 10 to 100A |
| Pressure | Max. 100 barg / 1450 psig |
| Process temperature | -40 to +150 C / -40 to +302 F |
| Measuring tube | Titanium (Ti-Grade 9), duplex 1.4462, Alloy 22, tantalum |
| Hygienic connections | Clamp DIN 32676 and ISO 2852, Tri-Clamp, DIN 11851 ferrule, DIN 11864-2 flange |
| Outputs | 4 to 20 mA, pulse, frequency, status, limit switches; HART, FOUNDATION Fieldbus, PROFIBUS PA/DP, Modbus RTU, EtherNet/IP, PROFINET, Ethernet-APL |
| Hygienic approvals as printed | FDA, 3A, EHEDG, EC 1935/2004, ASME BPE |
| Hazardous area as printed | ATEX, IECEx, NEPSI, EAC Ex, cFMus, INMETRO, KCs, UKEX |
Typical duties
The manufacturer names chemical batching to reactors, bulk loading, concentration and density measurement of acids and bases, plus dairy reception, juice Brix and density, liquid chocolate, syrup and CO2 injection in food plants. It also names viscous and non-homogeneous mixtures and slurries with entrained solids.
Because a straight tube drains easily and has no bends, it suits products that must be cleaned or emptied completely, and it keeps pressure drop low for viscous liquids.
Specifying a unit
The technical datasheet gives a table of sizes with their nominal flow rates; as printed in that table, size 06 is 1230 kg/h and size 25 is 44800 kg/h. Use it with your viscosity, density and pressure drop limits to choose the size, then choose tube material, connection and converter version.
Check Ex and custody-transfer certificates for the exact configuration before ordering. The hosted TD is dated 2015 (R01), so ask for the current revision and available fieldbus options when you send the request. A derived point: sensor and converter must be ordered as one verified system for fiscal use.
Related KROHNE products: KROHNE OPTIMASS 1400 Twin Tube Coriolis Mass Flowmeter, KROHNE OPTIMASS 6400 Coriolis Mass Flowmeter, KROHNE OPTIMASS 2400 High-Capacity Coriolis Mass Flowmeter, Krohne Optisonic 7300 Ultrasonic Gas Flowmeter, KROHNE OPTISONIC 3400 Ultrasonic Flowmeter and Krohne Optiflux 4300 Electromagnetic Flowmeter.
Documents and quotation
Seven Star LLC is an independent supplier in Muscat and can quote this item on request. The reference document is KROHNE OPTIMASS 7400 technical datasheet (EN), attached as a PDF; verify the tube material, size and approvals against it, then send us the type code for a quotation. Browse Flowmeters for alternatives.
Datasheets & Documents
- Datasheet KROHNE OPTIMASS 7400 technical datasheet (EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KROHNE is the German flow and level measurement company founded in Duisburg in 1921 as Ludwig Krohne & Sohn. Its first customers were Ruhr steel producers, for whom it built variable area flowmeters. KROHNE dates the first electromagnetic flowmeter for industrial process measurement to 1952. It is still family-owned and headquartered in Duisburg.
Seven Star LLC is an independent supplier in Muscat. We list KROHNE electromagnetic, Coriolis, ultrasonic and variable area flowmeters, radar level transmitters and flow computers, and supply them to water utilities, oil and gas and process plants in Oman and the GCC by order code.
KROHNE company profile
| Established | 1921, Duisburg, Germany, as Ludwig Krohne & Sohn |
|---|---|
| Early products | Variable area flowmeters for hardening furnaces in the Ruhr steel industry |
| Milestone | 1952: first electromagnetic flowmeter for industrial process measurement, according to KROHNE |
| Product families | Electromagnetic, Coriolis, ultrasonic, vortex and variable area flowmeters, radar and guided radar level, flow computers and metering systems, analysers |
Milestones
- 1921: Ludwig Krohne starts making variable area flowmeters in Duisburg for hardening furnaces in the Ruhr steel industry.
- 1952: First electromagnetic flowmeter for industrial process measurement, according to KROHNE.
- 1980: First ultrasonic flowmeter delivered to Shell for crude oil measurement.
- 1985: Development and production of Coriolis mass flowmeters begins.
- 1994: First Coriolis mass flowmeter with a single straight measuring tube.
- 1996: ALTOSONIC V, the first ultrasonic meter for custody transfer of liquids.
KROHNE products we list
| Family | Models | Typical use |
|---|---|---|
| Electromagnetic flowmeters | OPTIFLUX 2000, 2100, 2300, 4100, 4300, WATERFLUX 3070, 3100, 3300 | Water networks, wastewater, seawater intake and conductive process liquids |
| Coriolis mass flowmeters | OPTIMASS 1400, 6400 | Direct mass flow and density of hydrocarbons, chemicals and LPG |
| Ultrasonic flowmeters | ALTOSONIC V12, OPTISONIC 3400, 6300 clamp-on, 7300 gas | Gas custody transfer, liquid process flow and non-intrusive clamp-on checks |
| Variable area flowmeters | H250 M40, DK800/R | Simple, power-free flow indication for purge, sample and utility lines |
| Level | OPTIFLEX 7200 guided radar, OPTIWAVE 5400, 7500, 1540, OPTISWITCH 5300 | Level in tanks, separators and chemical storage, and point level switching |
| Flow computer | SUMMIT 8800 | Fiscal and custody transfer calculations for gas and liquid metering |
The flowmeter principle follows the medium. Electromagnetic meters need a conductive liquid, have no moving parts and no pressure loss, and suit water and slurries. Coriolis meters measure mass flow and density directly, so they work for hydrocarbons and non-conductive liquids. Ultrasonic meters handle gas and large pipes, and multi-path designs such as the ALTOSONIC V12 are used for custody transfer. Variable area meters need no power at all and give a simple local reading.
Where KROHNE instruments are used
In Oman and the GCC, KROHNE flowmeters and level transmitters are used in water transmission and distribution, desalination, wastewater, oil and gas production and fiscal metering, refineries, petrochemical and chemical plants, and power stations.
Ordering KROHNE instruments: what we need
Send the complete KROHNE order code or the nameplate data. For a new meter, send the medium, the flow range, pressure and temperature, the pipe size and flange rating, the liner and electrode materials (for electromagnetic meters), the output and communication, and the hazardous area classification.
Facts checked against KROHNE company history (100th anniversary), October 2026.
Browse KROHNE products by category: Flowmeters, Level Transmitter, Flow Computers.
FAQ
Questions about the KROHNE OPTIMASS 7400 Straight-Tube Coriolis Mass
Answers from our engineering team on installation, compatibility and integration.
01What accuracy does it have?
+/-0.1 percent of measured value for mass, density and volume, with OIML class 0.3 for custody transfer.
02Which tube materials are listed?
Titanium, duplex stainless steel, Alloy 22 and tantalum.
03Does it handle gas entrainment?
Yes, Entrained Gas Management keeps the measurement running with gas bubbles in liquids.
04Is a hygienic version available?
A food and beverage version and hygienic approvals including 3A and EHEDG are listed.
05Can it be commissioned wirelessly?
Yes, via a secure Bluetooth link within about 20 m.


















Reviews
There are no reviews yet.