Danfoss 068U4281 TCAE Thermostatic Expansion Valve R22/R407C
Description
TCAE: a stainless-steel straight-through expansion valve for R22 and R407C
The 068U4281 is a Danfoss TCAE thermostatic expansion valve for R22/R407C. Unlike the angled TUBE, this valve is a straightway design with a 1/2 in ODF solder inlet, a 5/8 in ODF outlet and a 1/4 in ODF equalization connection, so it drops straight into a liquid line without an elbow. The body is stainless steel and the bimetal connections are steel/copper.
The store entry lists a 1.5 m capillary, an evaporating range of -40 to 10 C, a maximum working pressure of 45.5 bar (660 psig) and a factory static superheat of 4 C with adjustable superheat setting. The flow direction is shown as bi-flow with orifice 1-2, and UL lists the valve for R22 and R407C.
Technical specifications
| Parameter | Specification |
|---|---|
| Danfoss code number | 068U4281 |
| Type | TCAE |
| Approvals as listed | EAC; UL; UA |
| Body material | Stainless steel |
| Capillary tube length | 59 in / 1500 mm |
| Equalization connection type | Solder, ODF |
| Equalization size | 1/4 in |
| Inlet connection type | Solder, ODF |
| Inlet size | 1/2 in |
| Maximum working pressure | 45.5 bar |
| Outlet connection type | Solder, ODF |
| Outlet size | 5/8 in |
| Pressure equalization | Externally equalized |
| Rated capacity conditions | OS=4K; tcond=38 C; tevap=4.4 C; tliq=37 C |
| Refrigerants | R22/R407C |
| Static Superheat (SS) | 4 C |
| Superheat setting | Adjustable |
| Temperature range | -40 C to 10 C |
| UL approved refrigerants | R22; R407C |
| Net weight | 0.205 kg |
| EAN | 5702428052108 |
Selecting a TCAE orifice and charge
This TCAE family is the larger-capacity sibling of the TUA/TCBE style valves: capacity is chosen by the orifice assembly, which is a replaceable part in this version (the page shows spare parts available for the TXV). That makes a TCAE a sensible choice for a fleet of packaged chillers or condensing units where several capacities share one body.
Select the orifice number from the capacity table in the data sheet for your refrigerant, evaporating temperature and liquid temperature, then keep the evaporator pressure drop in mind because the valve has an external equalizer. This code is the R22/R407C charge; an R410A or R134a unit needs a different charge and code.
Installation checks before you order
Fit the bulb on the horizontal suction line at 12 o’clock or 4 and 8 o’clock positions depending on pipe size, insulate it and keep it clear of oil traps. Connect the 1/4 in equalizer line downstream of the bulb. Protect the body from heat while brazing so that the diaphragm and seats are not damaged.
Confirm orifice number, refrigerant, connection sizes and approval needs against the attached data sheet. The Danfoss installation guide for TCBE / TCCE / TCAE and the TUA / TUAE / TCAE orifice guide cover the exchange procedure.
After brazing and before the bulb is insulated, check that the capillary has not been kinked or crushed by pipe clips, since a damaged capillary loses charge slowly and the valve then starves the evaporator.
Documents and quotation
Attached for download: Danfoss Thermostatic expansion valve, TU / TC AI561224665278en-000102 (manufacturer, unaltered), the manufacturer’s unaltered PDF. Browse comparable products in control valves. To order, send us 068U4281 and the required quantity; Seven Star LLC is an independent supplier based in Muscat.
Datasheets & Documents
- Datasheet Danfoss Thermostatic expansion valve, TU / TC AI561224665278en-000102 (manufacturer, unaltered) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Danfoss is the Danish engineering group that makes refrigeration and air-conditioning controls, heating components, variable speed drives and mobile hydraulics. Mads Clausen founded it on 1 September 1933 at his parents' farm in Nordborg on the island of Als, after making his first refrigeration expansion valve in 1932. Nordborg is still the group's headquarters, and Danfoss remains controlled by the Clausen family through the Bitten & Mads Clausen Foundation.
Danfoss company profile
| Founded | 1 September 1933, Nordborg, Denmark, by Mads Clausen (1905–1966) |
|---|---|
| First product | Thermostatic expansion valve for refrigeration |
| Headquarters | Nordborg, Denmark |
| Ownership | Private; majority controlled by the Bitten & Mads Clausen Foundation and the Clausen family |
| Size | About 42,000 employees (2023) |
| Business segments | Danfoss Climate Solutions (refrigeration, air conditioning and heating), Danfoss Drives (VLT and VACON frequency converters, soft starters), Danfoss Power Solutions (mobile and industrial hydraulics) |
| Brands in the group | VLT, VACON, Eaton Hydraulics (bought 2021), Ikusi radio remote controls |
Milestones
- 1932–1933: First expansion valve; the company is founded in Nordborg.
- 1939: 26 employees. By the 10th anniversary in 1943 the company has 179.
- 1950s: Rapid growth turns Nordborg into a Danfoss town with housing and schools for its workforce.
- 1968: Danfoss launches its VLT frequency converter, one of the first mass-produced AC drives.
- 2014: Acquisition of the Finnish drives maker Vacon, now the VACON brand.
- 2021: Acquisition of Eaton's hydraulics business.
Choosing Danfoss products
For solenoid valves, check the operating principle. A direct-operated valve such as EV210B opens even at 0 bar differential pressure. A servo-operated valve such as EV220B needs a minimum differential (typically about 0.3 bar) to open, while an assisted-lift valve such as EV250B works from 0 bar. Coils are ordered separately, so the voltage on the coil (for example 230 V AC or 24 V DC) must match the control circuit. For drives, the VLT family is split by application: FC 51 Micro Drive for small machines, FC 102 HVAC Drive for fans and pumps in buildings, FC 202 AQUA Drive for water, and FC 302 AutomationDrive for demanding industrial duty.
Where Danfoss products are used
In Oman and the GCC, Danfoss drives run pumps, fans and compressors in district cooling plants, water and wastewater stations, desalination and building HVAC. Danfoss pressure switches, transmitters and solenoid valves are built into chillers, refrigeration plants, boilers and hydraulic systems, and AB-QM valves balance chilled-water circuits in large buildings.
Danfoss products we list
| Family | Examples |
|---|---|
| Variable speed drives and soft starters | VLT Micro Drive FC 51, VLT HVAC Drive FC 102, VLT AQUA Drive FC 202, VLT AutomationDrive FC 302, FC 280, iC2-Micro, VACON NXP, MCD 600 soft starter |
| Solenoid valves and coils | EV220B, EV210B, EV250B, EV225B steam, EVR 25, AM230C coil |
| Pressure switches and thermostats | KP 37, KP 44, RT 200, CS, MBC 5000, KPS 77, RT 101 |
| Pressure transmitters | MBS 3000, MBS 5100, MBS 3250, MBS 4251 Ex, AKS 33, DST P92S SIL 2 |
| HVAC and refrigeration valves | AB-QM PICV, NovoCon S, AB-PM, AVTA, ICV, TE 5 element |
Ordering Danfoss products: what we need
Send the Danfoss code number from the label (for example 032U7115 or 131B0149) or the full drive type code (FC-302P3K0T5...). For drives, add the motor power, supply voltage and any fieldbus option. For valves, add the size, connection, medium and coil voltage. For pressure switches and transmitters, add the range, output and pressure connection.
Facts checked against Danfoss's company history pages and published company data, October 2026.
Browse Danfoss products by category: AC Drives, Pressure Instrumentation, Control Valves, Solenoid Valve.
Related products
Frequently Asked Questions
A TCAE thermostatic expansion valve for R22/R407C with 1/2 in ODF inlet, 5/8 in ODF outlet and external equalization.
The store entry shows TXV spare parts for this code and a bi-flow description tied to orifice sizes 1 and 2; see the installation guide for orifice exchange.
45.5 bar (660 psig).
-40 to 10 C as listed on the product page.
The Danfoss TU / TC data sheet AI561224665278en-000102 in unaltered form. Check orifice and charge before ordering.