Yokogawa UT32A-D Dual-Loop Digital Indicating Controller
Description
Two independent PID loops in one 48 x 96 mm panel cut-out
The Yokogawa UT32A-D is the dual-loop version of the UT32A. It puts two independent control loops in a narrow 48 x 96 mm panel instrument, with two universal inputs, two control outputs and a 14-segment colour LCD whose PV colour changes on alarm. It suits skids and machines that run two temperature or two pressure loops side by side, such as twin heating zones, a heater and a cooler, or two extruder or dryer zones, where two single-loop controllers would otherwise take twice the panel space.
Each loop has PID or ON/OFF control, four target setpoints, four alarm setpoints and four PID parameter sets, auto-tuning in Normal or Stable mode, the Super overshoot-suppressing and Super 2 hunting-suppressing functions, and preset output functions for stop, input error and manual operation. The control period is 200 ms. A ladder sequence function is standard and LL50A parameter-setting software (sold separately) builds ladder programs on a PC.
Technical specifications
| Parameter | Specification |
|---|---|
| Model | UT32A-D dual-loop type, 48 x 96 mm panel mounting |
| Control | Dual-loop PID or ON/OFF; control period 200 ms |
| Universal inputs | 2 points: thermocouple, RTD, DC voltage, DC current |
| Control outputs | 2 points: 4-20 / 0-20 mA or voltage pulse; 2 x 1a relay, 3 A at 240 V AC or 30 V DC |
| Alarm outputs | 3 x 1a relay, 1 A at 240 V AC or 30 V DC |
| Contact inputs | 3 points standard |
| Setpoints and PID | 4 target setpoints, 4 alarm setpoints and 4 PID sets per loop |
| Communication | RS-485 up to 38.4 kbps, 2-wire or 4-wire (Type 2 code 1) |
| Ladder sequence | Included as standard |
| Protection | IP66 front panel; NEMA 4 (hose-down test only) |
| Supply | 100-240 V AC, 15 VA; 24 V AC/DC with /DC |
| Operating temperature | -10 to 50 C |
| Depth and weight | 65 mm from panel surface; 0.5 kg or less |
Inputs, outputs and model code
The two universal inputs accept thermocouples, RTDs and DC voltage or current signals, with the accuracy table shown on the datasheet (for example plus or minus 0.1 percent of the instrument range for most ranges). There are two control outputs, each available as a current output (4 to 20 mA or 0 to 20 mA) or voltage pulse for time-proportional control, plus two 1a control relay contacts rated 3 A at 240 V AC or 3 A at 30 V DC. Alarms are three 1a relay outputs rated 1 A at 240 V AC or 30 V DC, and three contact inputs are standard. A heater break alarm option measures heater current through an external current transformer.
The model code is UT32A with Type 1 fixed at -D (dual-loop type), Type 2 (0 none, 1 RS-485 up to 38.4 kbps, 2-wire or 4-wire), Type 3 fixed 0, display language (-1 English, -2 German, -3 French, -4 Spanish), case colour (0 white, 1 black) and fixed code -00. Option codes are /HA heater break alarm (when Type 2 is 0), /DC 24 V AC/DC supply, /CT coating and /CV terminal cover. The /CT option removes UL, CSA and CE conformity. DIN-rail mounting is covered separately in GS 05P08D81-01EN.
Installation and what to confirm before ordering
The front is IP66 (NEMA 4 for the hose-down test only), the case is polycarbonate (UL94 V-0), weight is 0.5 kg or less, the panel depth is 65 mm and wiring is by M3 screw terminals. Supply is 100 to 240 V AC at 15 VA, or 24 V AC/DC with /DC. Operating temperature is -10 to 50 C. Confirm that two independent loops are what you need rather than cascade control, which belongs to the UT55A and UT75A; the sensor types for each loop; the output type for each actuator; RS-485 if a PLC connection is needed; and the panel cutout. The attached file is the Yokogawa general specification GS 05P08D31-01EN for the UT32A-D. Other controllers are in controllers and data acquisition. Send the full code for a quotation.
How the Yokogawa UT32A-D works
Each loop reads its own input and compares it with the target setpoint. The controller then calculates a PID output for that loop. It sends the output to the heater, valve or other final element. Both loops run side by side in the same case.
Where the UT32A-D is used
- Twin heating zones
- Heater and cooler pairs
- Extruder zones
- Dryer zones
- Machine and skid panels
Selection checklist for the UT32A-D
- Input signal types
- Output type per loop
- Relay or current output
- Alarm count
- Communication need
- Supply voltage
- Panel cut-out
- Ladder program need
Installation, commissioning and maintenance notes for the UT32A-D
Cut the 48 x 96 mm panel opening and fit the controller from the front. Wire the two inputs and the two outputs. Set the input type and range for each loop. Run auto-tuning on each loop and check the alarms.
Requesting a quotation for the Yokogawa UT32A-D
Please send the input types, the output types and the supply voltage. Seven Star LLC serves industrial customers in Oman and the GCC and replies with a quotation based on the information provided.
UT32A-D controller type
It is a dual-loop digital indicating controller.
UT32A-D panel size
It fits a 48 x 96 mm panel cut-out.
UT32A-D control loops
It has two independent control loops.
UT32A-D control mode
Each loop uses PID or ON/OFF control.
UT32A-D control period
The control period is 200 ms.
UT32A-D universal inputs
It has two universal inputs.
UT32A-D input types
The inputs take thermocouple, RTD, DC voltage and DC current.
UT32A-D control outputs
It has two control outputs.
UT32A-D output types
The outputs are 4-20 mA, 0-20 mA or voltage pulse.
UT32A-D relay outputs
Two 1a relays carry 3 A at 240 V AC.
UT32A-D alarm relays
Three 1a alarm relays carry 1 A at 240 V AC.
UT32A-D contact inputs
It has 3 contact inputs as standard.
UT32A-D setpoints
Each loop has 4 target setpoints and 4 alarm setpoints.
UT32A-D PID sets
Each loop has 4 PID parameter sets.
UT32A-D display
It has a 14-segment colour LCD.
UT32A-D alarm colour
The PV colour changes on alarm.
UT32A-D auto-tuning
Auto-tuning works in Normal or Stable mode.
UT32A-D overshoot function
The Super function suppresses overshoot.
UT32A-D hunting function
The Super 2 function suppresses hunting.
UT32A-D ladder sequence
A ladder sequence function is standard.
UT32A-D programming software
LL50A software builds ladder programs on a PC and is sold separately.
UT32A-D communication
It has RS-485 up to 38.4 kbps.
UT32A-D front protection
The front panel is rated IP66.
UT32A-D supply
Supply is 100-240 V AC, or 24 V AC/DC with the /DC option.
UT32A-D depth and weight
It is 65 mm deep and weighs 0.5 kg or less.
Controller records for the UT32A-D
Record the tuning values and the alarm settings for each loop.
Choosing the right UT32A-D output type
Choose the output type from the heater or valve you drive.
Datasheets & Documents
- Datasheet Yokogawa UT32A-D dual-loop digital indicating controller general specifications GS 05P08D31-01EN Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Yokogawa instruments are ordered by model and suffix code, a string such as EJX110A followed by option characters that fix span, materials and approvals. Founded in 1915 and headquartered in Tokyo, Yokogawa makes field instruments, process analyzers and the CENTUM control system used in refineries, gas plants and power stations.
Seven Star LLC is an independent supplier listing Yokogawa pressure transmitters, flowmeters, temperature transmitters, analyzers and CENTUM I/O modules for users in Oman and the GCC.
Yokogawa product families on this page
Pressure is covered by the DPharp transmitters: the EJX110A differential pressure transmitter, the EJX530A and EJA530E in-line gauge pressure transmitters and the EJX910A multivariable transmitter. The ADMAG AXW is the magnetic flowmeter line, and the YTA610 and YTA710 are temperature transmitters. Analyzers include the FLXA402 four-wire and FLXA21 two-wire liquid analyzers, the TDLS8000 tunable diode laser gas analyzer and spare parts for zirconia oxygen analyzers, such as the E7042UD cell assembly kit for the ZR22 detector. Control hardware includes CENTUM VP I/O modules like the ADV161 digital input module and the YS1700 programmable indicating controller.
Where Yokogawa instruments are used
EJA and EJX transmitters measure pressure, level and DP flow throughout oil and gas, chemical and power plants. Zirconia oxygen analyzers and the TDLS8000 are used for combustion control on boilers and fired heaters. FLXA analyzers monitor pH, conductivity and dissolved oxygen in water and process streams, and CENTUM modules are bought as replacements for running control systems.
Ordering Yokogawa parts: what we need
Send the model and suffix code and the serial number from the nameplate, and for CENTUM modules the style code as well. For transmitters without a code we need span, output protocol, wetted materials, process connection, housing and the approval required. For oxygen analyzer spare parts give the detector and converter models, for example ZR22G and ZR402G, and the part number.
Browse Yokogawa products by category: PLC & I/O Cards, Flowmeters, Pressure Instrumentation, Automation Accessories, Temperature Instrumentation.
Related products
Frequently Asked Questions
Yes. It provides two independent PID or ON/OFF loops with two universal inputs and two control outputs.
48 x 96 mm with 65 mm depth behind the panel.
200 ms.
RS-485 up to 38.4 kbps is available through the Type 2 code 1.
Yes, three 1a alarm relays rated 1 A at 240 V AC or 30 V DC.

Reviews