Brand: ABB
ABB TA25DU1.4 Thermal Overload Relay
Description
ABB TA25DU1.4 thermal overload relay, 1.0 to 1.4 A
The ABB TA25DU1.4 is a three-pole thermal overload relay with a current setting range of 1.0 to 1.4 A and trip class 10A. ABB identifies this execution by order code 1SAZ211201R1023. It belongs to the TA25DU family of bimetal relays designed to mount directly on ABB A-line block contactors, forming a compact direct-on-line starter for small three-phase motors.
At this current range the relay typically protects small pumps, fans, conveyors and auxiliary drives, where the motor full-load current printed on the nameplate falls between 1.0 and 1.4 A. Seven Star LLC supplies the TA25DU1.4 on request for panel builders and maintenance teams in Oman and the GCC.
Key features of the ABB TA25DU1.4
- Adjustable setting from 1.0 to 1.4 A, set on the front dial to the motor full-load current.
- Trip class 10A for normal motor starting duty.
- Direct mounting on ABB block contactors A9 to A40 and AL9 to AL40.
- Auxiliary contacts: one normally open and one normally closed contact for the contactor coil circuit and signalling.
- Automatic or manual reset, selectable on the relay.
- Trip-free mechanism, test function and trip indication on the front.
- Temperature compensation of the bimetal elements.
Technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / type | ABB / TA25DU1.4 thermal overload relay |
| Order code | 1SAZ211201R1023 |
| Number of poles | 3 |
| Current setting range | 1.0 to 1.4 A |
| Trip class | 10A |
| Rated operational voltage, main circuit | 690 V AC |
| Auxiliary contacts | 1 NO + 1 NC |
| Reset | Automatic or manual |
| Functions | Trip-free mechanism, test function, trip indication, temperature compensation |
| Mounting | Directly on block contactors A9–A40 and AL9–AL40 |
| Auxiliary contact ratings, ambient range, terminal data | Confirm against the manufacturer datasheet |
Operating principle
Each of the three main current paths heats a bimetal strip. When the motor current stays above the set value for long enough, the strips bend far enough to operate the trip mechanism, which opens the normally closed auxiliary contact in the contactor coil circuit and closes the normally open contact for signalling. The contactor then disconnects the motor. Trip class 10A means the relay is designed for motors that reach full speed within a normal starting time.
Temperature compensation reduces the effect of panel ambient temperature on the trip point. Because the relay responds to the current in all three poles, a lost phase increases the current in the remaining poles and leads to tripping. The relay does not provide short-circuit protection; fuses or a circuit breaker upstream must be selected according to ABB coordination tables.
Typical applications
- Direct-on-line starters for small three-phase motors on pumps, fans, mixers and conveyors.
- Motor feeders in packaged HVAC units, water treatment skids and machine control panels.
- Replacement of a failed or mis-set relay in an existing A-line starter.
Selection and ordering notes
- Set to the motor nameplate current: the motor full-load current at the supply voltage must lie within 1.0 to 1.4 A; motor power alone is not enough.
- Use the full order code: 1SAZ211201R1023 identifies this execution. ABB India lists a TA25DU-1.4M with code 1SAZ211201R2023 and the same range; the difference between the two codes should be confirmed against the manufacturer datasheet before substitution.
- Check the contactor: direct mounting applies to A9–A40 and AL9–AL40 block contactors. Other contactor families need a different relay or a separate mounting kit.
- Setting example: a motor with a nameplate current of 1.2 A at the site voltage is set to 1.2 A on the dial. If the nameplate current is at the edge of the range, such as 1.0 or 1.4 A, compare the neighbouring TA25DU ranges and choose the relay whose range places the setting comfortably inside the scale.
- Spares: where several identical starters are installed, record each relay setting on the panel drawings so that a replacement ABB TA25DU1.4 can be set correctly before the motor is restarted.
- Short-circuit protection: select fuses or a breaker according to ABB coordination data for the contactor and relay combination.
Installation and commissioning
- Isolate the starter before working on it.
- Mount the ABB TA25DU1.4 directly on the contactor main terminals and tighten the connections as specified in the ABB instructions.
- Wire the NC contact in series with the contactor coil and the NO contact to the alarm or PLC input as required.
- Set the dial to the motor nameplate full-load current and choose automatic or manual reset according to the site safety practice; manual reset is usual where automatic restart could be dangerous.
- Use the test function to confirm that the contactor drops out, then reset and start the motor.
Maintenance and troubleshooting
- Nuisance trips: measure the running current in all three phases and compare it with the setting; check for high panel temperature, loose terminals and long starting times.
- Trip on start only: check whether the motor load needs a longer starting time than trip class 10A allows.
- Relay will not reset: allow the bimetals to cool, then check the reset mode selection.
- After a trip: find the cause, such as a jammed pump, failed bearing or lost phase, before restarting.
Legacy status
The TA25DU range has been used on ABB A-line starters for many years. ABB documentation reviewed here does not state an end-of-life date or a named successor for the TA25DU1.4. Lifecycle status is confirmed at quotation.
Quotation enquiries for Oman and the GCC
Seven Star LLC supplies the ABB TA25DU1.4 on request; availability, condition and lead time are confirmed at quotation. Please send:
- The exact reference TA25DU1.4 and order code 1SAZ211201R1023 (or the code on the label).
- The quantity.
- A photograph of the relay nameplate and of the motor nameplate.
- The contactor reference and the application.
Technical support with selection and cross-checking of the reference is available.
Datasheets & Documents
- Catalog ABB Motor Control Catalogue — May 2010 Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
ABB is the Swiss-Swedish engineering group for electrification and automation: low voltage drives, motors, circuit breakers and motor control, process instruments and analysers, control systems and robots. It was formed on 5 January 1988 by the merger of two older companies. ASEA was founded in Västerås, Sweden, in 1883 by Ludvig Fredholm to make electric lighting and generators. BBC Brown Boveri was founded in Baden near Zurich in 1891 by Charles E. L. Brown and Walter Boveri. ABB Ltd is incorporated in Switzerland, headquartered in Zurich and listed on the SIX Swiss Exchange and Nasdaq Stockholm.
ABB company profile
| Formed | 5 January 1988, by the merger of ASEA (Sweden) and BBC Brown Boveri (Switzerland), each holding 50% |
|---|---|
| ASEA | Founded 1883 in Västerås, Sweden, by Ludvig Fredholm; first products electric lighting and generators |
| Brown, Boveri & Cie | Founded 1891 in Baden, Switzerland, by Charles E. L. Brown and Walter Boveri |
| Headquarters | Zurich, Switzerland; ABB Ltd became the group holding company in 1999 |
| Ownership | Public company listed on SIX Swiss Exchange and Nasdaq Stockholm |
| Brands in the group | Baldor (US motors, acquired 2011), B&R (machine automation, acquired 2017), K-TEK level instruments, Endura and Navigator analysers, SACE breakers |
| Product families | Low and medium voltage drives (ACS series), motors, SACE Tmax and Emax breakers, contactors and soft starters, flow, pressure, temperature and level instruments, liquid and gas analysers, Contrac actuators, AC500 PLCs, Ability System 800xA and S800 I/O, protection relays, robots |
Milestones
- 1883: ASEA is founded in Västerås, Sweden.
- 1891: Brown, Boveri & Cie is founded in Baden, Switzerland.
- 1987–1988: The merger is announced on 10 August 1987; ABB Asea Brown Boveri starts operating on 5 January 1988.
- 1999: ABB Ltd, incorporated in Switzerland, becomes the single holding company of the group.
- 2011 and 2017: Baldor Electric and B&R join ABB.
- 2020: ABB sells its power grids business to Hitachi, focusing on electrification, motion, process and machine automation.
Choosing an ABB drive
ABB's ACS drive codes are easy to read once you know the pattern. In ACS580-01-046A-4, "ACS580" is the drive family, "01" means a wall-mounted single drive, "046A" is the rated output current (about 46 A) and "-4" means a 380–480 V supply. The family is chosen by application: ACS355 for compact machinery, ACS310 for simple pumps and fans, ACS580 as the general-purpose drive, ACQ580 for water and wastewater with pump functions such as pipe fill and dry-run protection, and ACS880 for heavy industrial duty with direct torque control. Size the drive on the motor's full-load current, not only its kW rating, and allow derating for the high ambient temperatures common in Gulf electrical rooms.
Where ABB products are used
In Oman and the GCC, ABB drives and motors run pumps, fans and compressors in water and wastewater plants, district cooling, oil and gas and industry. ABB flowmeters, level instruments and analysers are used in water utilities, power and desalination plants and refineries, and SACE breakers protect switchboards in buildings and plants.
ABB products we list
| Family | Examples |
|---|---|
| AC drives | ACS580, ACS580-01-046A-4, ACQ580, ACS355, ACS310, ACS880-01, FEN-31 encoder module |
| Breakers, motor control and protection | SACE Tmax XT, XT3N 250, SACE Emax 2, AF09 contactor, PSR soft starter, REM615 relay |
| Flow measurement | ProcessMaster FEP300, AquaMaster4, CoriolisMaster FCB430, VortexMaster FSV430, SwirlMaster FSS430, OriMaster FPD500 |
| Pressure, temperature and level | 266DRH, 267CS multivariable, TTH300, K-TEK AT100, LMT200, MT5000 GWR, KM26 gauge |
| Analysers | Endura AZ20, AK100 hydrogen purity, Navigator AW641 silica, AW402 chlorine, AWT210 |
| Control systems and actuators | AC500, AC500-S, S800 AI810, AC 800F SA 811F, Contrac RSD50, Contrac RHD4000 |
Ordering ABB products: what we need
Send the full type code from the nameplate (for example ACS580-01-046A-4 or 266DSH...) and, for spare parts, the ABB ID number (such as 3BSE008508R1 or 1SBL176001R3010). For drives, add the motor power and current and any option codes (+...). For instruments, send the complete order code, which sets range, materials and approvals. Baldor motors are listed on their own brand page.
Frequently requested ABB models: ABB FENA-21 Two-Port Ethernet Adapter Module, ABB AHM550.
Facts checked against ABB company filings and published histories of ASEA and Brown, Boveri & Cie, October 2026.
FAQ
Questions about the ABB TA25DU1.4 Thermal Overload Relay
Answers from our engineering team on installation, compatibility and integration.
01What current range does the ABB TA25DU1.4 cover?
It is adjustable from 1.0 to 1.4 A and should be set to the motor full-load current from the nameplate.
02Which contactors does it mount on?
ABB lists direct mounting on A9 to A40 and AL9 to AL40 block contactors.
03What trip class does it have?
Trip class 10A, intended for motors with normal starting times.
04Does it protect against short circuits?
No. It is an overload relay; short-circuit protection must come from fuses or a circuit breaker chosen with ABB coordination data.
05Is TA25DU-1.4M the same item?
ABB India lists TA25DU-1.4M under code 1SAZ211201R2023 with the same range, but the difference from 1SAZ211201R1023 should be confirmed against the manufacturer datasheet.


















Reviews