Brand:

Yokogawa EJX910A Multivariable Transmitter

Description

Overview

The Yokogawa EJX910A is a multivariable transmitter that consolidates differential pressure, static (line) pressure, and process temperature measurement into a single field device, then computes compensated mass or volumetric flow internally. Built on Yokogawa’s DPharp single-crystal silicon resonant sensor technology, the EJX910A eliminates the need for three separate transmitters and an external flow computer in orifice-plate and averaging pitot tube applications, cutting installation cost, wiring runs, and maintenance points while improving the overall accuracy of the flow calculation.

As a supplier of Yokogawa products, Seven Star LLC supplies the EJX910A Multivariable Transmitter to process plants, refineries, and utility operators across the Sultanate of Oman and the wider GCC, backed by local technical support with selection and specification.

Measurement Principle

The Yokogawa EJX910A uses a single-crystal silicon resonant sensor (DPharp) that converts applied differential and static pressure into a resonant frequency shift, a mechanism that is inherently more stable and repeatable over time than strain-gauge or capacitive designs. A dedicated RTD input captures process temperature simultaneously. All three raw variables – differential pressure, static pressure, and temperature – are digitized and processed by an internal microprocessor running the flow compensation algorithm associated with the connected primary element, whether an orifice plate, averaging pitot tube, nozzle, or Venturi.

Because pressure and temperature compensation happen inside the same housing that senses the differential pressure, signal transmission delay and calculation error introduced by separate devices are removed. The practical result for the end user is a single 4-20 mA/HART, FOUNDATION Fieldbus, or Modbus RS485 output that already represents fully compensated mass flow, with static pressure and temperature available as secondary variables for asset monitoring, without any additional flow computer, extra cabling, or extra points of potential failure.

Engineering Design of the Yokogawa EJX910A

The Yokogawa EJX910A is available with L, M, or H capsule ranges to match the differential pressure span of the installed primary element, with a maximum working pressure of up to 3,600 psi (250 bar) on the M/H capsules and a burst pressure rating of 10,000 psi across the range. Process connections follow IEC 61518 3-valve and 5-valve manifold standards in T-style, H-style, wafer-style, and bottom-connection configurations, allowing the transmitter to be fitted directly to existing orifice flange taps or pitot tube tap arrangements without custom piping.

The electronics housing is available in standard aluminum alloy or optional stainless steel, rated to the same explosion-proof, flameproof, and intrinsically safe certifications as the rest of the EJX series, and the local digital indicator can be rotated in 90-degree increments for readability from any installation orientation. Configuration is performed through Yokogawa’s FieldMate FlowNavigator software, which walks the technician through primary-element data entry, unit selection, and range setting via an FDT/DTM interface, and allows a validated configuration to be copied across multiple identical installations to reduce commissioning time on multi-run metering skids.

Key Features

The Yokogawa EJX910A brings together several engineering advantages that make it a preferred choice for compensated flow measurement across the GCC process industry:

  • Combines differential pressure, static pressure, and temperature measurement in one transmitter, eliminating the separate flow computer traditionally required for orifice and averaging pitot tube metering.
  • DPharp silicon resonant sensor technology delivers differential pressure accuracy of ±0.04% of span and static pressure accuracy of ±0.1% of span, supporting mass flow accuracy of ±1.0% of range.
  • Fast response time of 200-230 ms on the differential pressure signal suits dynamic custody transfer and allocation metering duties.
  • Supports HART (revision 5 or 7), FOUNDATION Fieldbus, and Modbus RS485 protocols, plus an optional ISA100 wireless adapter for retrofit metering points without new cable runs.
  • IEC 61518-compliant manifold compatibility allows direct mounting to existing orifice and pitot tube tap arrangements in T-style, H-style, wafer-style, or bottom-connection formats.
  • Maximum working pressure up to 3,600 psi and burst pressure of 10,000 psi provide a wide safety margin for high-pressure gas and steam service.
  • FieldMate FlowNavigator configuration software simplifies primary-element setup and allows validated settings to be replicated across multiple identical flow runs.
  • SIL2/SIL3-capable design supports use in safety instrumented systems for critical flow monitoring loops.

Industrial Applications

The Yokogawa EJX910A is widely applied wherever compensated mass or volumetric flow must be derived from a differential-pressure primary element, including natural gas custody transfer and allocation metering, steam flow measurement in power and district cooling plants, compressed air metering in industrial utility systems, and hydrocarbon flow measurement in upstream and midstream oil and gas facilities. Its ability to output fully compensated flow without an external flow computer makes it particularly valuable on remote wellhead pads and unmanned metering skids where minimizing panel space and wiring is a priority.

As the trusted supplier for Yokogawa, Seven Star LLC distributes the EJX910A to oil and gas operators, refineries, district cooling providers, and utility companies throughout Oman, including projects supported from the Sohar and Salalah economic zones, as well as broader GCC markets, with lead time confirmed at quotation and application engineering support for primary-element sizing and manifold selection.

Technical Specifications

The table below summarizes the principal specifications of the Yokogawa EJX910A Multivariable Transmitter, confirming why the Yokogawa EJX910A is specified on demanding custody transfer projects.

Parameter Specification
Model Yokogawa EJX910A
Measured Variables Differential pressure, static pressure, process temperature (RTD), compensated mass/volumetric flow
Differential Pressure Accuracy ±0.04% of span
Static Pressure Accuracy ±0.1% of span
Mass Flow Accuracy ±1.0% of range
External Temperature Accuracy ±0.9°F (±0.5°C)
Maximum Working Pressure 2,300 psi (L-capsule); 3,600 psi (M/H capsule)
Burst Pressure 10,000 psi (all capsules)
Response Time 200-230 ms
Process Connection IEC 61518 3-valve / 5-valve manifolds; T-style, H-style, wafer-style, bottom connection
Output / Protocols 4-20 mA HART (rev 5/7), FOUNDATION Fieldbus, Modbus RS485, optional ISA100 wireless
Housing Material Low-copper aluminum alloy or optional stainless steel
Configuration Software FieldMate FlowNavigator (FDT/DTM)

Ordering details for EJX910A

For EJX910A multivariable service, identify the differential-pressure span, static-pressure basis and temperature input. If the plant uses compensated flow, include the existing calculation and flow-element data.

Technical reference

Request a Quote for Yokogawa EJX910A

Seven Star LLC invites engineering, procurement, and instrumentation teams across Oman and the GCC to submit a formal request for quotation for the Yokogawa EJX910A Multivariable Transmitter. The Yokogawa EJX910A is supplied on request, with lead time confirmed at quotation. In Oman and the GCC, Seven Star LLC supplies common configurations on request, provides the manufacturer technical datasheet on request, and connects customers directly with our instrumentation division for manifold selection and primary-element sizing support. Contact Seven Star LLC today to receive a competitive quotation with current lead time and local technical support.

Browse the full Yokogawa range or see more Pressure Instrumentation products supplied by Seven Star LLC in Oman and the GCC.

Datasheets & Documents
  • PDF datasheet Yokogawa EJX910A Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Yokogawa is the Japanese measurement and industrial automation company behind the DPharp EJA and EJX pressure transmitters, CENTUM distributed control systems and ProSafe-RS safety systems. Tamisuke Yokogawa set it up in 1915 as an electric meter research institute in Shibuya, Tokyo. It began selling electric meters in 1917, was incorporated as Yokogawa Electric Works in 1920, and has been Yokogawa Electric Corporation since 1986. In 1975 it released CENTUM, which it describes as the world's first distributed control system.

Seven Star LLC is an independent supplier in Muscat. We list Yokogawa transmitters, flowmeters, analysers, controllers, recorders and CENTUM and ProSafe spare modules, and supply them to oil and gas, power, water and process plants in Oman and the GCC by model code.

Yokogawa at a glance

Established 1915, Shibuya, Tokyo, by Tamisuke Yokogawa with Ichiro Yokogawa and Shin Aoki
Milestones Electric meters from 1917; incorporated in 1920; CENTUM DCS in 1975; renamed Yokogawa Electric Corporation in 1986
Headquarters Tokyo, Japan
Product families Pressure and temperature transmitters, magnetic, vortex and Coriolis flowmeters, liquid and gas analysers, controllers and recorders, CENTUM VP DCS, ProSafe-RS safety systems and STARDOM controllers

Yokogawa products we list

Family Models Typical use
Pressure and DP transmitters EJA110E, EJA430E, EJA530E, EJX110A, EJX530A, EJX910A multivariable Pressure, level and DP flow measurement in process plants
Temperature transmitters YTA610, YTA710 RTD and thermocouple signals converted to 4-20 mA, HART or fieldbus
Flowmeters ADMAG AXG, ADMAG AXW, ROTAMASS TI, VY vortex, VF701 Water and conductive liquids, mass flow of hydrocarbons, steam and gas
Analysers TDLS8000 laser gas analyser, FLXA402, FLXA21 DO, E7042UD zirconia cell, K9471DS cover Combustion O2, in-situ gas analysis, pH, conductivity and dissolved oxygen
Controllers and recorders UT35A/UT32A, UT32A-D, UT55A/UT52A, UT75A, UP35A/UP32A, UP55A, YS1700, GX10/GX20, GP10/GP20, GM10, µR20000 Single-loop control, furnace programs and data recording
Control and safety systems CP451-10 processor, ADV161, ADV551, node interface unit, ProSafe-RS, ProSafe-RS Lite, ProSafe-SLS, FCN-500 Spares and expansions for CENTUM DCS, safety systems and STARDOM
Battery packs S9129FA, S9185FA, S9548FA Memory backup batteries for DCS and controller modules

The EJA and EJX transmitters use Yokogawa's DPharp sensor: two silicon resonators whose vibration frequency changes with pressure, so the output is a digital frequency rather than an analogue strain signal. The model code describes the instrument completely. In EJA110E, "110" is a differential pressure transmitter, and the letters after the dash set the span, wetted materials, process connection, electrical output and approvals. When you replace a transmitter, sending the full code from the nameplate avoids a mismatch in range or materials.

Where Yokogawa products are used

In Oman and the GCC, Yokogawa transmitters, analysers and control systems are found in oil and gas production, gas processing and LNG, refineries and petrochemical plants, power and desalination stations, and water treatment. Many plants still run CENTUM CS 3000 and CENTUM VP systems that need spare I/O modules and batteries.

Ordering Yokogawa products: what we need

Send the full model and suffix code from the nameplate (for example EJA110E-JMS5J-912NN/KF22) and the style code. For DCS modules, add the module type and system version. For analysers, send the sensor type, measuring range and process conditions.

Facts checked against Yokogawa's corporate history, October 2026.

FAQ

Questions about the Yokogawa EJX910A Multivariable Transmitter

Answers from our engineering team on installation, compatibility and integration.

01What does the Yokogawa EJX910A measure?
The EJX910A measures differential pressure, static pressure, and process temperature simultaneously, then computes fully compensated mass or volumetric flow internally, removing the need for a separate flow computer.
02Does the EJX910A reduce installation cost compared to separate transmitters?
Yes. Combining three measurement functions and the flow calculation into one DPharp-based device reduces wiring, panel space, manifold hardware, and commissioning time compared to installing separate DP, pressure, and temperature transmitters with an external flow computer.
03What primary elements is the EJX910A compatible with?
The EJX910A is compatible with orifice plates, averaging pitot tubes, flow nozzles, and Venturi tubes, using IEC 61518 3-valve or 5-valve manifolds in T-style, H-style, wafer-style, or bottom-connection formats.
04Can the EJX910A integrate with existing control systems?
Yes. It supports 4-20 mA HART (revision 5 or 7), FOUNDATION Fieldbus, and Modbus RS485 as standard, with an optional ISA100 wireless adapter available for retrofit metering points that lack existing cable infrastructure.
05Is Seven Star LLC a trusted supplier for Yokogawa products?
Yes, Seven Star LLC supplies Yokogawa products to customers in Oman and the GCC and can provide the manufacturer documentation and technical support on request.