Siemens Maxum II Veriflow Air-Actuated Valve 1671004-103
Description
Overview: Reliable Sample Isolation for Process Gas Chromatography
The Siemens Maxum II Veriflow Air-Actuated Valve, part number 1671004-103, is a pneumatic diaphragm valve rated to 3.77 bar (40 psig), used within the Siemens Maxum Edition II process gas chromatograph as a sample shut-off valve. Diaphragm valve technology is widely used in process analyzer sampling systems because it isolates the actuating mechanism from the process fluid entirely, minimizing dead volume and contamination risk in the sample path that feeds the analyzer’s separation columns and detectors.
As an independent specialized supplier of Siemens Maxum Edition II analyzer spare parts, Seven Star LLC sources and supplies the Veriflow valve 1671004-103 to refineries, gas plants, and petrochemical complexes across Oman and the wider GCC.Seven Star LLC supplies this item on request with the manufacturer documentation, and availability and lead time are confirmed at quotation.
Working Principle: Air-Actuated Diaphragm Shut-Off
The Veriflow valve operates by using pneumatic actuation air to flex a diaphragm against a valve seat, physically isolating the flow path without any sliding stem seal in direct contact with the sample fluid. When actuation air pressure is applied, the diaphragm lifts away from the seat, allowing sample flow through the valve body; when actuation air is removed or reversed, the diaphragm returns to seal against the seat, shutting off flow. This diaphragm-based design eliminates the packing-gland leak paths associated with traditional stem-sealed valves, an important consideration for sample systems handling process streams that may be flammable, toxic, or otherwise hazardous.
Because the valve is air-actuated rather than solenoid-actuated directly at the valve body, it integrates cleanly with the Maxum Edition II’s centralized Solenoid Valve Control Module (SVCM) architecture, which routes pilot air to the diaphragm actuator on command from the analyzer’s system controller. This keeps electrical components away from the sample stream entirely, supporting safe operation in hazardous-area sampling system installations.
Engineering Design of the Veriflow Valve
The 1671004-103 valve is built to the 40 psig (3.77 bar) actuation pressure rating specified for Maxum Edition II sampling system service, with a compact body sized for direct integration into the analyzer’s sample conditioning and stream-selection manifold. Its diaphragm-based construction is chosen specifically for sample shut-off duty, where clean, repeatable isolation matters more than high-cycle-rate switching performance.
As with other pneumatically actuated valves in the Maxum II sampling system, correct installation depends on connecting the actuation air line to the appropriate SVCM output and verifying valve response during commissioning or after replacement, ensuring the shut-off function operates reliably as part of the analyzer’s overall sample safety interlock scheme.
Key Features
The Veriflow Air-Actuated Valve 1671004-103 provides dependable sample isolation for the Maxum Edition II sampling system. Key characteristics include:
- Diaphragm-based construction with no stem packing in contact with the sample fluid.
- Rated to 3.77 bar (40 psig) actuation pressure for standard Maxum II sampling system service.
- Air-actuated design compatible with the analyzer’s centralized SVCM pilot-air architecture.
- Used specifically as a sample shut-off valve within the sampling and stream-selection manifold.
- Genuine Siemens Maxum II part number for correct fit and safety-certified operation.
Industrial Applications
The Veriflow valve is used throughout Maxum Edition II sampling systems wherever a clean, leak-tight shut-off point is required in the sample conditioning path, including isolating the analyzer from the process stream during maintenance, supporting safety interlock logic that shuts off sample flow on fault conditions, and general sample stream management in refinery, gas processing, and petrochemical analyzer installations.
Seven Star LLC supports refinery instrumentation teams, gas processing operators, and petrochemical maintenance departments across Oman, Muscat, Sohar, and the broader GCC region with sourcing of Maxum Edition II sampling system valves, helping analyzer houses maintain safe, reliable sample delivery to their process gas chromatographs.
Technical Specifications
The table below summarizes the core specifications of the Siemens Maxum II Veriflow Air-Actuated Valve as supplied by Seven Star LLC.
| Parameter | Specification |
|---|---|
| Model / Part Number | Veriflow Air-Actuated Valve, P/N 1671004-103 |
| Valve Type | Air-actuated diaphragm valve |
| Function | Sample shut-off |
| Actuation Pressure | 3.77 bar (40 psig) |
| Target Platform | Siemens Maxum Edition II Process Gas Chromatograph |
| Control Interface | Pilot air from Solenoid Valve Control Module (SVCM) |
| Hardware Condition | New, genuine Siemens part number |
Why Choose Seven Star LLC for Maxum II Sampling System Valve Sourcing
A sample shut-off valve on a hazardous process stream is a safety-relevant component, not a routine wear part – verifying the exact actuation pressure rating and SVCM compatibility before ordering matters because a mismatched valve can either fail to seal properly or fail to respond correctly to the analyzer’s safety interlock logic. Seven Star LLC’s sourcing team confirms the Veriflow valve’s actuation pressure and SVCM wiring configuration against the customer’s specific Maxum II sampling system before the part ships, rather than assuming a generic diaphragm valve will integrate correctly. We also help refinery and gas plant instrumentation teams plan spare valve stock for sampling systems handling flammable or toxic streams across Muscat, Sohar, and the broader GCC, since a compromised sample shut-off point is not something a facility can leave unresolved between scheduled maintenance visits.
Request a Quote for Siemens Maxum II Veriflow Air-Actuated Valve 1671004-103
Seven Star LLC is a dedicated supplier of Siemens Maxum Edition II process gas chromatograph spare parts and sampling system valves throughout Oman and the GCC. To request a formal B2B quotation, verify current availability and lead time, or confirm compatibility of the Veriflow Air-Actuated Valve 1671004-103 with your specific Maxum II sampling system, contact our instrumentation sourcing team today.
Related Products
- AMETEK 300-8707 Copper Hollow Cathode Lamp (Cu HCL)
- Siemens Maxum II Model 50 Ten-Port Valve 2017660-003
- Teledyne C70043A PCB Assembly, Paramagnetic Preamp for MDL 3000 Series
- AMETEK 16052JE-MIRROR Protected Gold Mirror
- Michell Condumax II CD2-SCR-002 Hydrocarbon Dew-Point Sensor Cell
- PR Electronics 5335D 2-Wire HART Transmitter for RTD and TC
Reviews (0)
How would you rate this product? Cancel reply
About brand
Siemens is the German technology group whose industrial products include SIMATIC controllers and HMIs, SINAMICS drives, SIRIUS and SENTRON switching and protection devices, SIPROTEC protection relays, SITRANS process instruments, SCALANCE networks and process analysers. It was founded in Berlin on 12 October 1847 by Werner von Siemens and the precision mechanic Johann Georg Halske as Telegraphen-Bauanstalt von Siemens & Halske, to build Siemens's newly designed pointer telegraph. Siemens AG is headquartered in Munich and listed on the Frankfurt Stock Exchange; its energy business was spun off as Siemens Energy in 2020.
Siemens company profile
| Founded | 12 October 1847, Berlin, Germany, as Telegraphen-Bauanstalt von Siemens & Halske, with 10 employees |
|---|---|
| Founders | Werner von Siemens (1816–1892) and Johann Georg Halske (1814–1890) |
| First product | The pointer telegraph designed by Werner von Siemens |
| Headquarters | Munich, Germany (Siemens AG) |
| Ownership | Public company listed in Frankfurt; Siemens Energy (2020) and Siemens Healthineers are separately listed companies |
| Businesses acquired that appear in our range | Moore Products (bought in 2000; APACS and QUADLOG control systems), Applied Automation (Maxum process gas chromatographs); small industrial gas turbines such as the SGT-300 came with Alstom's industrial turbine business in 2003 |
| Product families | SIMATIC S7 PLCs, ET 200 distributed I/O and HMI panels, TIA Portal software, SINAMICS drives, SIMOTICS motors, SIRIUS and SENTRON low voltage devices, SIVACON switchboards, SIPROTEC relays, SITRANS instruments, SCALANCE network components, building technology valves and sensors |
Milestones
- 1847: Siemens & Halske starts work in Berlin with 10 employees.
- 1848: The company wins the contract for Europe's first long-distance telegraph line, Berlin to Frankfurt am Main.
- 1856: 330 employees, two-thirds of them working on telegraph networks in Russia.
- 1866: Werner von Siemens describes the dynamo-electric principle, the basis of the electric generator.
- 1958 onwards: The SIMATIC name is used for Siemens industrial automation; S7 PLCs follow in the 1990s and S7-1500 in 2012.
- 2020: Siemens Energy is spun off and listed separately.
Choosing Siemens automation products
A Siemens order number (MLFB) identifies the exact product: 6ES7 is SIMATIC automation, 6AV is HMI, 6GK is industrial communication, 6SL is SINAMICS drives, 3R is SIRIUS control and 5SY is SENTRON miniature circuit breakers. For PLCs, S7-1200 is the compact controller for small machines, S7-1500 is the current mid-to-high range controller, and S7-300 and S7-400 are older platforms still running in many plants; S7-300 is being phased out, so spares and migration to S7-1500 are common requests. When replacing a CPU or module, the full order number including the version digits matters, because firmware and hardware versions affect compatibility with the existing project.
Where Siemens products are used
In Oman and the GCC, Siemens automation runs in oil and gas, power and desalination plants, water networks, cement and process industries. Maxum gas chromatographs analyse gas composition in gas plants and refineries, SIPROTEC relays protect substations, SGT-300 turbines drive generators and compressors, and Siemens building valves are used in HVAC systems.
Siemens products we list
| Family | Examples |
|---|---|
| SIMATIC controllers and I/O | S7-1500, CPU 1515-2 PN, S7-1200, CPU 1214C, S7-300, S7-400H CPU 412-5H, ET 200SP, IM 153-2 |
| HMI and networking | KTP700 Basic, TP700 Comfort, TP1200 Comfort, SCALANCE XC208, SCALANCE WAM766, PROFIBUS OLM |
| Drives, motors and power distribution | SINAMICS G120C, SINAMICS G120X, 1LA7 motor, SIVACON S8, SIPROTEC 7SJ85, 5SY4510-7 MCB |
| Process instruments | SITRANS P320, MAG 5100W, SITRANS TH320, SITRANS TS500, SITRANS TR200 |
| Maxum II analyser spares | FID 302A detector, FPD II assembly, filament detector, Model 50 valve, SYSCON kit, air bath heater |
| APACS and QUADLOG spares | QLCCM24AAN, QLSAMBAN, QLSDM024DCCBN, 39SAMCAN, 16137-151 M-BUS cable |
| Building technology | VPI46 PICV, VPF44, QFM1660 sensor |
Ordering Siemens products: what we need
Send the full order number from the label (for example 6ES7214-1AG40-0XB0) and, for PLC and HMI parts, the hardware and firmware version (FS and V numbers). For Maxum II and APACS spares, send the Siemens part number such as 2021651-002. For drives, add the motor power and supply voltage.
Frequently requested Siemens models: Siemens IM 155-6 PN ST ET 200SP Interface Module 6ES7155-6AU02-0BN0, Siemens SGT-300 Industrial Gas Turbine.
Facts checked against Siemens's published history timeline, October 2026.
FAQ
Questions about the Siemens Maxum II Veriflow Air-Actuated Valve
Answers from our engineering team on installation, compatibility and integration.
01What function does the 1671004-103 Veriflow valve serve?
It functions as a sample shut-off valve within the Maxum Edition II sampling system, isolating the analyzer from the process sample stream when required.
02Why is a diaphragm valve used for sample shut-off?
Diaphragm valves isolate the actuating mechanism from the process fluid entirely, eliminating stem-packing leak paths and minimizing dead volume in the sample path.
03What actuation pressure does this valve require?
The valve is rated to 3.77 bar (40 psig) actuation pressure, matching the standard Maxum Edition II sampling system specification.
04How is the valve controlled on the analyzer?
The valve is air-actuated, receiving pilot air from the analyzer's Solenoid Valve Control Module (SVCM) on command from the system controller, keeping electrical components away from the sample stream.
05Does Seven Star LLC supply this part across the GCC?
Yes, Seven Star LLC sources and supplies the Siemens Maxum II Veriflow Air-Actuated Valve 1671004-103 to refinery, gas processing, and petrochemical customers across Oman and the wider GCC region.