- Automation & ControlView all 2,897 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: KROHNE
KROHNE OPTIFLUX 2000 Electromagnetic Flowmeter
Description
Overview
KROHNE OPTIFLUX 2000 is an electromagnetic flow sensor engineered as the single-platform solution for water, wastewater, and general process flow measurement. Rather than offering one fixed design, the OPTIFLUX 2000 sensor combines with the IFC 050, IFC 100, or IFC 300 signal converters to form the OPTIFLUX 2050, 2100, or 2300 flowmeter – giving plant engineers one sensor platform that scales from basic utility metering to advanced diagnostic-rich process control. Its full-bore, obstruction-free design and welded stainless steel construction make it equally suited to clean potable water, abrasive slurries, and corrosive chemical duties.
Working closely with plant engineers in the region, Seven Star LLC proudly supplies the OPTIFLUX 2000 electromagnetic flowmeter to industrial, municipal, and utility customers across Oman and the wider GCC. Every unit supplied through Seven Star LLC comes with manufacturer documentation and access to local technical support – helping facility engineers and procurement teams in Muscat, Sohar, and Salalah receive a correctly specified instrument.
Measurement Principle
The KROHNE OPTIFLUX 2000 operates on the principle of electromagnetic induction, first described by Faraday’s Law. As an electrically conductive liquid flows through the magnetic field generated inside the sensor, it induces a voltage that is directly proportional to the liquid’s velocity. Two measuring electrodes in contact with the fluid pick up this induced voltage, and the connected signal converter processes it into a precise volumetric flow value. Because the excitation is modern pulsed DC, the flowmeter is inherently resistant to zero-point drift, a common failure mode in older electromagnetic designs.
This measuring principle gives the KROHNE OPTIFLUX 2000 several practical advantages that matter on real installations. There are no moving parts and no constrictions inside the flow tube, so the meter introduces virtually no pressure drop – performing hydraulically like a plain section of pipe. It is unaffected by changes in fluid density, viscosity, or turbulence profile, and because nothing protrudes into the flow stream, it will not clog, wear, or foul even when measuring liquids carrying solids, fibers, or entrained bubbles. This makes the sensor equally suitable for raw sewage, pulp slurries, and demineralized water without any change in measuring accuracy.
Engineering Design of the KROHNE OPTIFLUX 2000
The OPTIFLUX 2000 sensor is built with a fully welded stainless steel housing rated IP67/IP68, allowing installation in permanently flooded chambers, buried pits, and underground vaults without compromising the electronics. The wetted liner is available in a choice of corrosion- and abrasion-resistant materials to match the process fluid, and the flanged connection is offered across an exceptionally wide nominal diameter range up to DN 2000, with fitting lengths compliant with both DVGW and ISO standards for straightforward retrofit into existing pipe runs.
Because the sensor is decoupled from its signal converter, plant designers can mount the IFC 050, IFC 100, or IFC 300 converter remotely or compactly, matching the installation to the available space and hazardous-area requirements. In situ verification is supported through KROHNE’s MagCheck diagnostic tool, allowing technicians to confirm sensor performance without removing the flowmeter from the line – a significant maintenance advantage for buried or hard-to-access installations common in regional water distribution networks.
Key Features
The KROHNE OPTIFLUX 2000 electromagnetic flowmeter delivers a combination of accuracy, durability, and diagnostic depth that few single-platform sensors can match, which is why the KROHNE OPTIFLUX 2000 remains a preferred choice for demanding utility and process applications.
- The sensor combines with IFC 050, IFC 100, or IFC 300 converters to form the OPTIFLUX 2050, 2100, or 2300 flowmeter, covering basic to advanced applications from one hardware platform.
- 3×100% diagnostics detect measurement errors that standard SIL2-certified equipment cannot recognize, including erroneous readings caused by entrained gas bubbles.
- Fully welded IP67/IP68 stainless steel construction allows reliable operation in permanently flooded chambers and buried installations.
- The obstruction-free, full-bore design produces virtually zero pressure drop and requires no upstream or downstream straight-pipe runs.
- International drinking water approvals and compliance with OIML R-49 and ISO 4064 support potable water metering and utility billing applications.
- In situ verification with KROHNE MagCheck confirms sensor accuracy on-site without process interruption or removal from the pipeline.
- A wide nominal diameter range up to DN 2000 covers everything from small process lines to large municipal transmission mains.
- Modern pulsed DC excitation eliminates the zero-shift drift found in legacy electromagnetic flow sensor designs.
Industrial Applications
Facility engineers across the region specify the KROHNE OPTIFLUX 2000 because it is deployed across water and wastewater utilities, power generation, pulp and paper production, metals and mining, and general process industries wherever accurate, low-maintenance flow measurement of conductive liquids is required. Typical duties range from potable and raw water to seawater, groundwater, wastewater, sludge, and sewage, as well as cooling water circuits and leak-detection monitoring on long-distance transmission networks.
With fast quotation turnaround and technical support, Seven Star LLC distributes the OPTIFLUX 2000 to district cooling operators, municipal water authorities, RO desalination plants, and industrial facilities throughout Oman and the GCC. The flowmeter is a strong fit for the water distribution networks and industrial zones of Sohar and Salalah, where buried and flooded chamber installations are common, as well as for commercial HVAC and district cooling plants across Muscat that require dependable, drift-free flow data for billing and process control.
Technical Specifications
The table below summarizes the core specifications of the KROHNE OPTIFLUX 2000 electromagnetic flow sensor, giving buyers of the KROHNE OPTIFLUX 2000 a single reference for sizing and converter selection.
| Parameter | Specification |
|---|---|
| Model | KROHNE OPTIFLUX 2000 |
| Measuring Principle | Electromagnetic induction (Faraday’s Law) |
| Nominal Diameter Range | DN25 – DN2000 (1″ – 48″) |
| Compatible Signal Converters | IFC 050, IFC 100, IFC 300 |
| Resulting Flowmeter Models | OPTIFLUX 2050, OPTIFLUX 2100, OPTIFLUX 2300 |
| Ingress Protection | IP67 / IP68 |
| Housing Material | Fully welded stainless steel |
| Approvals & Compliance | OIML R-49, ISO 4064, international drinking water approvals |
| Diagnostics | 3×100% self-diagnostics (exceeds SIL2 detection capability) |
| Verification Tool | KROHNE MagCheck (in situ, no process interruption) |
| Excitation | Pulsed DC (zero-shift resistant) |
| Typical Applications | Water & wastewater, pulp & paper, mining, power generation, cooling systems |
Request a Quote for KROHNE OPTIFLUX 2000 Electromagnetic Flowmeter
Ordering the KROHNE OPTIFLUX 2000 through Seven Star LLC is straightforward: our team supports the full procurement cycle for the KROHNE OPTIFLUX 2000 electromagnetic flowmeter, from formal RFQ submission to availability and lead-time confirmation, technical datasheet delivery, and direct consultation with our instrumentation division on sizing, liner selection, and converter matching for your application. With engineering support in Muscat, we supply every OPTIFLUX 2000 flowmeter on request with manufacturer documentation and dependable local technical support. Contact Seven Star LLC today to request a quotation or discuss your flow measurement project.
Related Products
Datasheets & Documents
- Datasheet KROHNE OPTIFLUX 2000 Electromagnetic Flowmeter Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
KROHNE is the German flow and level measurement company founded in Duisburg in 1921 as Ludwig Krohne & Sohn. Its first customers were Ruhr steel producers, for whom it built variable area flowmeters. KROHNE dates the first electromagnetic flowmeter for industrial process measurement to 1952. It is still family-owned and headquartered in Duisburg.
Seven Star LLC is an independent supplier in Muscat. We list KROHNE electromagnetic, Coriolis, ultrasonic and variable area flowmeters, radar level transmitters and flow computers, and supply them to water utilities, oil and gas and process plants in Oman and the GCC by order code.
KROHNE company profile
| Established | 1921, Duisburg, Germany, as Ludwig Krohne & Sohn |
|---|---|
| Early products | Variable area flowmeters for hardening furnaces in the Ruhr steel industry |
| Milestone | 1952: first electromagnetic flowmeter for industrial process measurement, according to KROHNE |
| Product families | Electromagnetic, Coriolis, ultrasonic, vortex and variable area flowmeters, radar and guided radar level, flow computers and metering systems, analysers |
Milestones
- 1921: Ludwig Krohne starts making variable area flowmeters in Duisburg for hardening furnaces in the Ruhr steel industry.
- 1952: First electromagnetic flowmeter for industrial process measurement, according to KROHNE.
- 1980: First ultrasonic flowmeter delivered to Shell for crude oil measurement.
- 1985: Development and production of Coriolis mass flowmeters begins.
- 1994: First Coriolis mass flowmeter with a single straight measuring tube.
- 1996: ALTOSONIC V, the first ultrasonic meter for custody transfer of liquids.
KROHNE products we list
| Family | Models | Typical use |
|---|---|---|
| Electromagnetic flowmeters | OPTIFLUX 2000, 2100, 2300, 4100, 4300, WATERFLUX 3070, 3100, 3300 | Water networks, wastewater, seawater intake and conductive process liquids |
| Coriolis mass flowmeters | OPTIMASS 1400, 6400 | Direct mass flow and density of hydrocarbons, chemicals and LPG |
| Ultrasonic flowmeters | ALTOSONIC V12, OPTISONIC 3400, 6300 clamp-on, 7300 gas | Gas custody transfer, liquid process flow and non-intrusive clamp-on checks |
| Variable area flowmeters | H250 M40, DK800/R | Simple, power-free flow indication for purge, sample and utility lines |
| Level | OPTIFLEX 7200 guided radar, OPTIWAVE 5400, 7500, 1540, OPTISWITCH 5300 | Level in tanks, separators and chemical storage, and point level switching |
| Flow computer | SUMMIT 8800 | Fiscal and custody transfer calculations for gas and liquid metering |
The flowmeter principle follows the medium. Electromagnetic meters need a conductive liquid, have no moving parts and no pressure loss, and suit water and slurries. Coriolis meters measure mass flow and density directly, so they work for hydrocarbons and non-conductive liquids. Ultrasonic meters handle gas and large pipes, and multi-path designs such as the ALTOSONIC V12 are used for custody transfer. Variable area meters need no power at all and give a simple local reading.
Where KROHNE instruments are used
In Oman and the GCC, KROHNE flowmeters and level transmitters are used in water transmission and distribution, desalination, wastewater, oil and gas production and fiscal metering, refineries, petrochemical and chemical plants, and power stations.
Ordering KROHNE instruments: what we need
Send the complete KROHNE order code or the nameplate data. For a new meter, send the medium, the flow range, pressure and temperature, the pipe size and flange rating, the liner and electrode materials (for electromagnetic meters), the output and communication, and the hazardous area classification.
Facts checked against KROHNE company history (100th anniversary), October 2026.
Browse KROHNE products by category: Flowmeters, Level Transmitter, Flow Computers.
FAQ
Questions about the KROHNE OPTIFLUX 2000 Electromagnetic Flowmeter
Answers from our engineering team on installation, compatibility and integration.
01What makes the KROHNE OPTIFLUX 2000 different from a fixed electromagnetic flowmeter?
The OPTIFLUX 2000 is a sensor platform rather than a single fixed model. It combines with the IFC 050, IFC 100, or IFC 300 signal converter to form the OPTIFLUX 2050, 2100, or 2300 flowmeter, letting you match converter capability to your application without changing the sensor hardware. This simplifies spare parts, engineering, and inventory management across multiple sites.
02Does installing the OPTIFLUX 2000 require pipe modification or process shutdown?
The sensor is a flanged, full-bore device that fits standard DVGW and ISO installation lengths, so it can be installed during normal pipeline construction or a planned tie-in without special straight-pipe runs upstream or downstream. Because it has no moving parts, ongoing maintenance downtime is minimal compared with mechanical meters.
03What sizes and materials are available for the OPTIFLUX 2000?
The sensor is available across a wide nominal diameter range from DN25 up to DN2000, with a choice of corrosion- and abrasion-resistant liner materials selected to match the process fluid, from clean potable water to abrasive slurries and corrosive chemicals.
04Can the OPTIFLUX 2000 replace an older electromagnetic or mechanical flow meter?
Yes. Its standard flanged connections and ISO/DVGW fitting lengths make it a straightforward drop-in replacement for legacy magnetic flow sensors, and its full-bore, wear-free design makes it a reliable upgrade path from mechanical water meters in drinking water distribution networks.
05Is Seven Star LLC an experienced supply partner for KROHNE products?
Yes, Seven Star LLC is an experienced supplier of KROHNE in Oman and the GCC. We supply KROHNE instrumentation with calibration documentation and local technical support.


















Reviews
There are no reviews yet.