Brand:

Winsonic DAU02-PNET-8AI PROFINET Remote I/O 8 AI Module

Description

The Winsonic DAU02-PNET-8AI is a PROFINET remote I/O module that measures eight analogue signals with 16-bit resolution. Each channel accepts 0 to 10 V, 0 to 20 mA or 4 to 20 mA, so one module can read pressure and level transmitters, temperature converters and flow signals and hand the values to a PLC over standard industrial Ethernet. Seven Star LLC is the authorized representative of Winsonic in Oman and serves customers across the GCC.

What sets the Winsonic DAU02-PNET-8AI apart

Analogue inputs are where accuracy numbers matter. The datasheet for the DAU02-PNET-8AI quotes accuracy of plus or minus 0.1 percent of full-scale range at 25 degrees C, widening to 0.3 percent over -10 to 60 degrees C and 0.5 percent over -30 to 75 degrees C. The converter samples all eight channels at 3164 samples per second, equal to 395.5 samples per second on each channel, and input impedance is at least 1 megohm for voltage signals. For current loops, a built-in 120 ohm resistor does the conversion.

Feature summary

  • 8 differential analogue inputs, voltage or current mode, 16-bit.
  • Ranges: 0 to 10 VDC, 0 to 20 mA and 4 to 20 mA.
  • PROFINET Device, MQTT, RESTful API, SNMP V1.0.
  • Two-port Ethernet switch for daisy-chain wiring.
  • Screw-fastened Euroblock terminals and DIN-rail or wall mounting.

Winsonic DAU02-PNET-8AI electrical data

Model DAU02-PNET-8AI
Analogue input channels 8
I/O mode Voltage / current
Input type Differential
Resolution 16 bits
Input range 0 to 10 VDC; 0 to 20 mA; 4 to 20 mA
Accuracy 0.1 percent FSR at 25 C; 0.3 percent at -10 to 60 C; 0.5 percent at -30 to 75 C
Sampling rate 3164 samples/s all channels; 395.5 samples/s per channel
Current-input resistor 120 ohm built in
Input impedance 1 megohm or more
Industrial protocol PROFINET Device
IoT protocols MQTT, RESTful API, SNMP V1.0
Cloud connectivity AWS, Azure, AIoTera
Ethernet ports 2 x 10/100BaseT(X), RJ-45, daisy-chain capable
Magnetic isolation 1.5 kV built-in
Configuration Web console (HTTP), Windows utility (device search)
Security Access control list
LED indicators Power, Status, Port 1, Port 2
Power input 12 to 36 VDC, one input, screw-fastened Euroblock terminal
Housing Plastic
Dimensions 27.8 x 124 x 84 mm
Weight 200 g
Mounting DIN-rail or wall
Operating temperature -10 to 60 degrees C standard; -40 to 75 degrees C wide-temperature models
Storage temperature -40 to 85 degrees C
Humidity 5 to 95 percent, non-condensing
Safety / EMC UL 508; EN 55032/24, EN 61000-6-2/-6-4; ESD 4 kV contact, 8 kV air
Green RoHS, WEEE

How DAU02-PNET-8AI differs from other DAU02 modules

The DAU02-PNET-16DI and DAU02-PNET-16DO handle sixteen on/off signals; the DAU02-PNET-8AI handles eight continuous signals. That means half the channels but 16 bits of resolution per channel. If a cabinet needs process measurement and discrete status, one DAU02-PNET-8AI plus one DAU02-PNET-16DI covers both. The DAU02 series also lists an 8AO analogue output module, which completes the loop for control applications.

Process uses in Oman and GCC plants

In water treatment the DAU02-PNET-8AI can read turbidity, pH converter and pressure outputs; in oil and gas it can bring 4 to 20 mA transmitter signals from non-hazardous areas back to a PROFINET controller; in power auxiliary systems it can read temperature transducers; in industry it can monitor tank levels and line pressures. With 395.5 samples per second per channel it is quick enough for most slow process variables.

Selection guidance

Decide per channel whether the signal is voltage or current and wire accordingly; the datasheet describes the mode as voltage or current, so confirm configuration with us before ordering for mixed networks. Use shielded twisted-pair cable, keep it away from power conductors and ground the shield at one end. Accuracy should be checked against the temperature range inside the cabinet.

Commissioning steps

Work through the inputs one at a time. Mount the module, supply 12 to 36 VDC, connect field cables of 16 to 26 AWG and attach Ethernet. Discover the module with the Auto-Search RIO utility, set its address and range in the web console, import the PROFINET description file into the controller and compare readings against a calibrator at the low, mid and high points of each range. Record the results, and repeat the check after any change to cabling, shielding or transmitter configuration so that drift is detected early.

Maintenance and recalibration

Check terminals and shield grounds periodically and verify readings against a reference when instruments are serviced. Keep configuration backups. SNMP provides remote health information. Because the datasheet widens the accuracy figure at temperature extremes, schedule recalibration checks sooner for modules installed in hot, unconditioned cabinets, and note the cabinet temperature on the calibration record. A spare module with the same configuration saved on file shortens downtime considerably when a plant must keep measuring without interruption.

Scaling, noise and grounding for the DAU02-PNET-8AI

Raw 16-bit values mean little until they are scaled to engineering units, so agree on the scaling for each transmitter in the controller program and document it. Differential inputs reject common-mode noise, which is useful in plants with variable-speed drives, but shield drains should still be terminated at a single point. For 4 to 20 mA loops, remember that a reading well below 4 mA indicates a broken wire or a failed transmitter, and program an alarm for that condition. Where several transmitters share a long cable tray, allow separation from power cables and avoid sharp bends that stress the conductors. Log a baseline reading at commissioning to compare with later checks. Remember that accuracy figures apply to the converter itself, so the total error of a loop also includes the transmitter, the cable and any signal isolators in the circuit.

Documents and quotation

We can supply the manufacturer datasheet for the DAU02-PNET-8AI as a PDF. Send an RFQ with part number DAU02-PNET-8AI, the quantity and the destination.

When you send the RFQ, also mention the PROFINET controller you use, the signal type on each of the eight channels and whether spare modules are needed for the site. We will confirm the label details, the current hardware revision and the lead time before the order is placed.

Other Models in the Dau02 Pnet Range

Seven Star LLC supplies models from the Dau02 Pnet range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Winsonic DAU02-PNET-16DI PROFINET Remote I/O 16 DI ModuleIndustrial CommunicationsView details
Winsonic DAU02-PNET-16DO PROFINET Remote I/O 16 DO ModuleIndustrial CommunicationsView details
Winsonic DAU02-PNET-8AI PROFINET Remote I/O 8 AI ModuleIndustrial CommunicationsYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Winsonic DAU02-PNET-8AI PROFINET Remote I/O 8 AI Module Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Rail-grade Ethernet switches with M12 connectors, industrial cellular routers and panel PCs are the Winsonic products buyers ask us for most. Winsonic is known as a maker of industrial LCD monitors and touch displays, and the products listed here add networking and computing hardware for places where office equipment does not survive: trains and buses, roadside cabinets, pump stations and factory floors.

Seven Star LLC is the Winsonic agency for Oman and the GCC and lists Winsonic EN 50155 switches, 4G and 5G routers and gateways, SFP transceivers, panel PCs and rack mount monitors.

Winsonic product families

The M12 switches on this page are specified to EN 50155, the standard for electronic equipment on rail vehicles. Listed models include the L2 managed NE10002 and the NE10003 in IP68 housings, the unmanaged NE10004 with 10G ports and IP65 sealing, the unmanaged NE10005 and the 5-port IP68 NE10006, with PoE+ or PoE++ ports depending on the model. On the cellular side the listing covers NE24 series industrial cellular routers and edge gateways, the NE20001 vehicle-grade 5G transit gateway and the NE31001 outdoor LTE-A router. WSFP Gigabit SFP transceivers provide the fiber uplinks. Computing and display products include the PZB zero bezel panel PC and the RM rack mount monitor, next to the flush mount and zero bezel LCD monitors Winsonic builds for industrial use.

Winsonic series at a glance

Series Use Models listed on this site
EN 50155 M12 switches Rail-grade switches with M12 connectors, IP65 or IP68, PoE+ or PoE++ NE10001, NE10002, NE10003, NE10004, NE10005, NE10006
Industrial Ethernet switches L3 and L2 managed ring switches and unmanaged switches, with PoE and SFP or SFP+ uplinks NE11001, NE11002, NE11003, NE11004, NE11005, NE11006, NE11007, NE11008, NE11009
Cellular VPN routers Industrial 4G and 5G routers, single or dual SIM NE21001, NE22001, NE22002, NE22003, NE22004, NE22005, NE22006, NE22007
Gateways 5G EN 50155 transit gateway, edge computing and energy gateways NE20001, NE24001, NE24002, NE24003, NE24004, NE24005
Outdoor and indoor routers LTE-A outdoor router and AX3000 WiFi router NE31001, NE31002
SFP and SFP+ transceivers Gigabit, SONET/SDH and 10G optical modules WSFP-C7-M85, WSFP-C7-S13, WSFP-C8-S35, WSFP-C8-S53, WSFP-E7-S13, WSPP-H7-M85, WSPP-H7-S13
Panel PCs and monitors 32 inch zero bezel panel PC and 27 inch 4K rack mount monitor PZB32014, RM2705

Where Winsonic equipment is used

Typical uses are on-board networks for trains, metro cars and buses, wayside cabinets, traffic management, remote pump stations and water plants, energy metering at unmanned sites, and machine monitoring and operator stations in factories.

Ordering Winsonic switches and routers: what we need

Send the complete part number, including the digits after the hyphen, because they separate variants of the same base model. Where you are still selecting, give us:

  • port count, port speed and connector type (M12 coding or RJ45)
  • PoE power needed per port and the supply voltage available
  • managed or unmanaged operation, and the IP rating required
  • for routers: mobile operator, SIM count, serial or Ethernet interfaces
  • for panel PCs: screen size, touch type, processor and mounting

Series and model data on this page come from the Winsonic product pages and manufacturer documents published on omansevenstar.com.

FAQ

Questions about the Winsonic DAU02-PNET-8AI PROFINET Remote I/O 8 AI

Answers from our engineering team on installation, compatibility and integration.

01What input ranges does the Winsonic DAU02-PNET-8AI support?
It supports 0 to 10 VDC, 0 to 20 mA and 4 to 20 mA on eight differential channels with 16-bit resolution.
02How accurate is the DAU02-PNET-8AI?
The datasheet lists plus or minus 0.1 percent FSR at 25 degrees C, 0.3 percent at -10 to 60 degrees C and 0.5 percent at -30 to 75 degrees C.
03What is the sampling rate of the DAU02-PNET-8AI?
3164 samples per second across all channels, which corresponds to 395.5 samples per second on each channel.
04How does the DAU02-PNET-8AI handle current inputs?
It has a built-in 120 ohm resistor for current inputs and an input impedance of at least 1 megohm for voltage signals.
05Which network protocols does the DAU02-PNET-8AI offer?
It is a PROFINET Device with MQTT, RESTful API and SNMP V1.0 support, plus AWS, Azure and AIoTera cloud connectivity and two Ethernet ports.