- Automation & ControlView all 1,920 products
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Industrial Computers
- Motor Soft Starters
- Servo Drives
- Pneumatic Cylinders
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric XVBC2B8 Harmony XVB Yellow 70 mm Indicator
Description
XVBC2B8 yellow 70 mm steady indicator bank unit
The XVBC2B8 is a Schneider Electric product listed in the datasheet as: Indicator bank, Harmony XVB, illuminated unit, plastic, yellow, 70mm, steady, integral LED, 24V AC/DC. The XVBC2B8 is a yellow Harmony XVB illuminated unit of 70 mm with steady light and an integral LED. Yellow typically warns of attention or abnormal conditions. Seven Star LLC supplies the XVBC2B8 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: B marks the LED variant and 8 the yellow colour. The datasheet shows it as discontinued.
Technical specifications of the XVBC2B8
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / XVBC2B8 |
| Description | Indicator bank, Harmony XVB, illuminated unit, plastic, yellow, 70mm, steady, integral LED, 24V AC/DC |
| Range of Product | Harmony XVB Universal |
| Product or Component Type | Indicator bank |
| Beacon or indicator bank unit | Illuminated unit |
| Signalling type | Steady |
| Mounting diameter | 70 mm |
| Component name | XVBC |
| Material | Polycarbonate |
| Light source | Integral LED, yellow |
| Bulb type | Protected LED |
| [Us] rated supply voltage | 24 V AC/DC |
| Assembly style | Customer assembly, up to 5 units |
| Connections – terminals | Screw clamp terminals, <= 1 x 1.5 mm² with cable end |
| [Ui] rated insulation voltage | 250 V IEC 60947-1 |
| Nominal voltage limit | 0.85 to 1.1 Un IEC 60947-5-1 |
| Current consumption | < 47 mA AC/DC |
| [Uimp] rated impulse withstand | 4 kV IEC 60947-1 |
| CAD overall width | 70 mm |
| CAD overall height | 63 mm |
| CAD overall depth | 70 mm |
| Net Weight | 0.15 kg |
| Pollution degree | 2 |
| Product Certifications | CCC; EAC; CSA C22-2 No 14; UL 508 |
| Standards | IEC 60947-5-1 |
| Ambient air temperature (operation or storage, as listed) | -40 to 70 °C |
| Electrical shock protection class | Class I on support tube IEC 61140; Class II on base unit IEC 61140 |
| IP degree of protection | IP65 on fixing base XVBZ0. IEC 60529; IP66 on base unit IEC 60529 |
| NEMA degree of protection | UL type 4X UL indoor |
Warning-light data of the XVBC2B8
Supply voltage: 24 V AC/DC.
The datasheet gives supply and consumption.
Using the XVBC2B8 in a tower
Yellow is placed between green and red. The green sibling XVBC2B3 shares the same base.
The datasheet downloaded for this page carries lifecycle notices: Discontinued on: Dec 31, 2025; End-of-service on: Jul 1, 2026. For a plant that already runs this reference that makes the XVBC2B8 a spare-and-replacement item, and it is worth fixing the stock level and the long-term successor plan at the same time. We can discuss compatible alternatives once we know the installation.
Selection checklist for the XVBC2B8
- Yellow.
- 70 mm.
- 24 V.
- Steady.
- Base.
- Lifecycle.
Wiring the XVBC2B8
Wire to the signal source and test.
Replace the unit when it fails.
Typical applications of the XVBC2B8 in Oman and the GCC
In Oman and the GCC it flags warnings on equipment.
Dimensions, environment and approvals of the XVBC2B8
The XVBC2B8 weighs 0.15 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: -40 to 70 °C. Ingress protection: IP65 on fixing base XVBZ0. IEC 60529; IP66 on base unit IEC 60529. Standards listed: IEC 60947-5-1. Certifications listed for this reference: CCC; EAC; CSA C22-2 No 14; UL 508.
A yellow unit like the XVBC2B8 is the attention colour in a signal tower, and its meaning should be defined in the plant standard: many sites use yellow for a warning that needs action but not an immediate stop, such as a low level, a filter blocked or a maintenance request. Wire it to a controller output through a relay or direct, as its LED consumption is low; check the datasheet for the current. The 70 mm yellow lens can look similar to an orange or amber lens in strong light, so avoid using both in one tower. The unit is part of a family with other colours such as the green XVBC2B3, and the units can be exchanged on the base to build a custom stack. As the datasheet lists the unit as discontinued, record the base type and tube length with the spare so a replacement can be selected quickly. Clean the lens regularly, since dust reduces visibility. When a tower has been in service for several years, plan a periodic lamp test: operators should see every colour light at least once a shift or after each start, so that a dead yellow unit is found early. Keep a simple one-page legend near the machine that states what steady yellow means and who should be called. If the plant also uses flashing yellow for a different meaning, document the difference clearly. Replace units in complete sets when the lenses on the same tower have started to yellow with age, so the colours stay matched.
Information to send with an RFQ for the XVBC2B8
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Site conditions in Oman for the XVBC2B8
Safety and analytical equipment in Gulf plants has to perform reliably in heat, dust and humidity. Before installing the XVBC2B8, check the operating temperature range, ingress protection and hazardous-area approvals against the actual location, and consider shading or weather protection for units exposed to direct sun. Sensor positioning should follow the gas properties and the site fire and gas philosophy, with access kept clear for testing.
Plan the test and calibration routine from the start. Record the configuration and alarm settings of each XVBC2B8, keep the required calibration gas or test equipment available, and agree a replacement interval for consumable parts so that the system stays compliant with the inspection regime at sites across Oman.
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Other Models in the Se Xvbc Range
Seven Star LLC supplies models from the Se Xvbc range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric XVBC2B3 Harmony XVB Green 70 mm Indicator | Alarm Beacons & Call Points | View details |
| Schneider Electric XVBC2B8 Harmony XVB Yellow 70 mm Indicator | Alarm Beacons & Call Points | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric XVBC2B8 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric XVBC2B8 Harmony XVB Yellow 70 mm
Answers from our engineering team on installation, compatibility and integration.
01What is the net weight of the XVBC2B8?
The datasheet gives 0.15 kg.
02What ingress protection does the XVBC2B8 list?
Stated as IP65 on fixing base XVBZ0. IEC 60529; IP66 on base unit IEC 60529.
03Which standards does the XVBC2B8 list?
Listed: IEC 60947-5-1.
04Which product range does the XVBC2B8 belong to?
The datasheet lists the range as Harmony XVB Universal.
05What is the rated operational voltage of the XVBC2B8?
Listed: 24 V AC/DC.


















Reviews