Schneider Electric LC1D25B7 TeSys Deca 25 A Contactor 24 V AC

Description

LC1D25B7: 25 A TeSys Deca contactor with 24 V AC coil

The LC1D25B7 is a Schneider Electric TeSys Deca contactor listed in the datasheet as: TeSys D contactor – 3P(3 NO) – AC-3 – ≤ 440 V 25 A – 24 V AC coil. The LC1D25 is the 25 A frame of the TeSys Deca range and the largest of the compact 45 mm wide bodies. Its AC-3 rating is 25 A at up to 440 V, which covers 11 kW motors at 400 V, and its body is 85 mm tall and 92 mm deep, a few millimetres larger than the 9 to 18 A versions. Seven Star LLC supplies the LC1D25B7 in Oman and the GCC as an independent supplier based in Muscat.

Decoding the reference from the datasheet title: LC1D is the three-pole TeSys Deca contactor, 25 is the 25 A frame, and B7 is the control voltage code, here a 24 V AC 50/60 Hz coil. This frame is also available with other coil codes, such as LC1D25F7, LC1D25P7. The datasheet gives dimensions of 85 x 45 x 92 mm (H x W x D) and a net weight of 0.37 kg.

Technical specifications of the LC1D25B7

Parameter Specification
Manufacturer / part number Schneider Electric / LC1D25B7
Description TeSys D contactor – 3P(3 NO) – AC-3 – ≤ 440 V 25 A – 24 V AC coil
Range of product TeSys Deca Advanced
Device short name LC1D
Product or component type Contactor
Contactor application Motor control; resistive load
Utilisation category AC-3; AC-3e; AC-1; AC-4
Poles / contact composition 3P; 3 NO
Rated operational voltage [Ue] Power circuit: up to 690 V AC (25 to 400 Hz); up to 300 V DC
Rated operational current [Ie] 25 A at <60 °C at up to 440 V AC (AC-3 and AC-3e); 40 A in AC-1
Control circuit voltage [Uc] 24 V AC 50/60 Hz
Coil technology Without built-in suppressor module
Inrush / hold-in power 70 VA inrush; 7 VA (50 Hz) and 7.5 VA (60 Hz) hold-in
Motor power (AC-3), 400 V 11 kW at 380/400 V
Motor power, 60 Hz 15 hp at 460/480 V
Conventional free-air thermal current 40 A at 60 °C
Rated making / breaking capacity 450 A at 440 V
Associated fuse rating 63 A gG (type 1) and 40 A gG (type 2) at up to 690 V
Auxiliary contacts 1 NO + 1 NC, mechanically linked; NC mirror contact
Mechanical durability 15 Mcycles
Electrical durability 1.65 Mcycles at 25 A AC-3; 1.4 Mcycles at 40 A AC-1
Maximum operating rate 3600 cycles per hour at 60 °C
Operating time 12 to 22 ms closing; 4 to 19 ms opening
Power terminals 2.5 to 10 mm² per terminal flexible without ferrule, 1.5 to 6 mm² for the second terminal with ferruled conductors
Tightening torque (power) 2.5 N.m
Mounting support Rail; plate
IP degree of protection IP20 front face (IEC 60529)
Ambient temperature -40 to 60 °C; 60 to 70 °C with derating
Operating altitude 0 to 3000 m
Dimensions (H x W x D) 85 x 45 x 92 mm
Net weight 0.37 kg
Product certifications UL; CCC; CSA; Marine; UKCA; EAC; CB Scheme

Ratings of the LC1D25B7 in motor and resistive duty

At 25 A AC-3 the datasheet lists 5.5 kW at 220/230 V, 11 kW at 380/400 V and 415/440 V and 15 kW at 500 V and 660/690 V, with 15 hp at 460/480 V and 20 hp at 575/600 V. In AC-1 it is rated at 40 A at 440 V, and the thermal current of the power circuit is 40 A at 60 °C.

Supply voltage (AC-3) Motor power
220/230 V 5.5 kW
380/400 V 11 kW
415/440 V 11 kW
500 V 15 kW
660/690 V 15 kW

Those motor ratings apply to AC-3 and AC-3e starting at up to 440 V; for AC-4 (plugging and inching) the datasheet gives a reduced figure, so a repetitive-reversing duty needs its own check. For the Omani and GCC 415 V network, the 380/400 V and 415/440 V rows are the relevant ones. Power circuit insulation is rated 690 V with an impulse withstand of 6 kV, overvoltage category III and pollution degree 3.

The 24 V AC coil on the LC1D25B7

The coil of the LC1D25B7 is rated 24 V AC 50/60 Hz. The datasheet gives an inrush of 70 VA (cos phi 0.75, at 20 °C) and a hold-in of 7 VA at 50 Hz and 7.5 VA at 60 Hz (cos phi 0.3). Dividing by the coil voltage, that is roughly 2.92 A at the moment of closing and 0.29 A while held in at 50 Hz; these are our own calculations from the VA figures and are only an order-of-magnitude guide for sizing control fuses and transformers. The coil has no built-in suppressor module, so a surge suppressor or RC network is an add-on if the coil is switched by a PLC output or a small relay. Control circuit voltage limits per the datasheet: drop-out between 0.3 and 0.6 Uc, operational at 0.8 to 1.1 Uc at 50 Hz and 0.85 to 1.1 Uc at 60 Hz in the range from -40 to 60 °C, and 1 to 1.1 Uc between 60 and 70 °C. A 24 V AC coil means the control side is fed from a control transformer secondary, which keeps the operator-facing wiring at extra-low voltage. The price of that is cable length: at 24 V the closing current is relatively large, so long runs to remote push buttons or float switches lose voltage and a contactor can fail to pull in even though the supply reads normal at the transformer.

Wiring a 24 V AC coil: keep the control cable short and of adequate section, because the closing current is the largest of all the AC voltages in this family. Fuse the transformer secondary for the total inrush of every coil that can close at once, and run the control pairs away from motor cables so induced voltage does not hold a released coil in.

Commissioning check on a 24 V AC coil: measure the voltage across A1 and A2 while the contactor is closing, not only when idle. If it drops below 0.8 Uc (19.2 V) during the pull-in, suspect a weak transformer, a thin control cable or a loose terminal, and fix that before blaming the contactor. Buzzing after closing usually means the voltage collapses once the coil draws its inrush.

Typical homes for the LC1D25B7: chiller and air-handling panels, lift and door controls, and packaged skids where the OEM fitted a 24 V AC control transformer. In those panels a 25 A contactor on a 24 V AC coil is selected because every other device in the control chain is already extra-low voltage.

Contacts, terminals and service life of the LC1D25B7

Power terminals accept 2.5 to 10 mm² flexible conductors in the first position and the datasheet specifies 2.5 N.m tightening for power terminals, higher than the 1.7 N.m of the smaller frames. The contactor mounts on rail or plate.

Mechanical life is 15 million cycles and electrical life 1.65 million at 25 A AC-3 and 1.4 million at 40 A AC-1. Making and breaking capacity at 440 V is 450 A, the highest of the compact range.

The LC1D25B7 within the LC1D25 range

All references below share the 25 A power section and differ in coil voltage. The datasheet data for ratings, terminals and endurance are the same across them; only the coil voltage changes. Against its neighbours, the 24 V AC coil is the one to pick only when the panel truly has a 24 V AC source. The 110 V, 230 V and 240 V versions draw far less current for the same VA, so they tolerate long wiring better, while the 24 V coil carries the lowest touch voltage. A 24 V AC coil cannot be replaced by a 24 V DC reference without changing the contactor.

Part number Coil voltage Note
LC1D25B7 24 V AC This page
LC1D25F7 110 V AC Same frame, different coil
LC1D25P7 230 V AC Same frame, different coil

Choosing the LC1D25B7: a checklist

  • Motor up to 11 kW at 400 V, or 15 hp at 460/480 V.
  • Resistive loads up to 40 A in AC-1.
  • Coil voltage, from the 24 V, 110 V or 230 V AC versions of the 25 A frame in this lane.
  • Cable size: the terminals take 2.5 to 10 mm² flexible, torque 2.5 N.m.
  • Short-circuit protection: 63 A gG type 1 or 40 A gG type 2.
  • Check that the control transformer secondary is 24 V AC and not 24 V DC, and that its VA rating covers the inrush of every coil closing at once.
  • Confirm the control supply really is 24 V AC before ordering the LC1D25B7; coil voltage cannot be changed on the contactor.

Where the LC1D25B7 works in Oman and the GCC

A 25 A contactor suits compressors, mixers, pump sets, fans and extractor motors in the 7.5 to 11 kW class on a 400 V supply. It is also used to switch heating elements up to 40 A, in process heaters and cabinet heater groups.

Because the coil is 24 V AC, typical use is HVAC panels, building services and machine controls with a control transformer. Ambient temperatures inside outdoor panels in Oman often exceed the 60 °C limit for full rating in summer; the datasheet allows operation to 70 °C with derating, but the usual practice is to shade, ventilate or air-condition the enclosure. Fine dust and humid coastal air call for sealed enclosures because the contactor itself is only IP20 on the front face.

Information to send with an RFQ for the LC1D25B7

  • The reference LC1D25B7 and the quantity required
  • Whether it replaces an existing LC1D25 contactor and the coil voltage printed on it
  • Motor power, supply voltage and starting method (direct-on-line, reversing, star-delta)
  • Number of auxiliary contacts and overload relay that will be fitted
  • Delivery location in Oman or the GCC and the timing needed

Documents and quotation

A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.

Send us the part number LC1D25B7, the quantity and the application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and is not affiliated with the manufacturer.

Other Models in the Se Lc1d25 Ac Range

Seven Star LLC supplies models from the Se Lc1d25 Ac range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric LC1D25B7 TeSys Deca 25 A Contactor 24 V ACContactors & Overload RelaysYou are viewing this model
Schneider Electric LC1D25F7 TeSys Deca 25 A Contactor 110 V ACContactors & Overload RelaysView details
Schneider Electric LC1D25P7 TeSys Deca 25 A Contactor 230 V ACContactors & Overload RelaysView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric LC1D25B7 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric LC1D25B7 TeSys Deca 25 A

Answers from our engineering team on installation, compatibility and integration.

01What is the AC-3 current rating of the LC1D25B7?
The datasheet lists 25 A at up to 440 V (AC-3 and AC-3e) and 40 A in AC-1.
02What coil voltage does the LC1D25B7 use?
The control circuit voltage is 24 V AC 50/60 Hz, a coil without a built-in suppressor module.
03How large a motor can the LC1D25B7 start at 400 V?
The datasheet gives 11 kW at 380/400 V in AC-3, and 15 hp at 460/480 V for three-phase 60 Hz motors.
04What are the dimensions and weight of the LC1D25B7?
The datasheet lists 85 x 45 x 92 mm (H x W x D) and a net weight of 0.37 kg.
05Does the LC1D25B7 include auxiliary contacts?
The datasheet lists an auxiliary contact composition of 1 NO + 1 NC, mechanically linked, with the NC acting as a mirror contact.