Schneider Electric EZC250F3250 EZC250F 250A 3P MCCB

Description

EZC250F3250: 250 A three-pole Easypact EZC250F breaker

EZC250F3250 identifies an Easypact EZC250F breaker, three-pole, built around a TM-D thermal-magnetic trip unit with fixed settings. Seven Star LLC supplies the EZC250F3250 in Oman and the GCC as an independent supplier based in Muscat.

How to read EZC250F3250: EZC250 is the frame, F marks the lower F breaking class of the 250 A frame, the digit 3 is the number of poles, and 250 is the rated current in amperes. The digits 250 at the end of the reference are the current rating: the datasheet lists [In] as 250 A at 40 °C and the thermal-magnetic trip unit rating as 250 A at 50 °C.

The datasheet title describes the breaker as 3 poles, 3d, and lists the protected poles as 3t, so every phase is protected by the trip unit. There is no neutral pole to switch on this version; if your system needs a switched neutral, look at the four-pole sibling of the same frame.

Where the EZC250F3250 is used in Oman and the GCC

Easypact EZC breakers are aimed at distribution boards. In Oman and across the GCC that means commercial buildings, hotels, villas and compounds, workshops, warehouses and the utilities of small industrial sites, where moulded case breakers protect feeders between a main board and the floor, plant or pump boards. The EZC250F3250 is typically specified for the main incomer of a medium board or a rising-main tap-off, using the full 250 A of the frame.

The datasheet gives an operating range of -25…70 °C and a storage range of -35…85 °C with IP20 protection, so the breaker belongs in an enclosure. Panels in direct sun, uncooled plant rooms and humid coastal sites run hotter than ambient inside, so allow for the internal temperature when you load the breaker close to its rating.

Information to send with an RFQ for the EZC250F3250

A short list of facts lets us confirm the EZC250F3250 quickly and avoid ordering the wrong class or rating.

  • Part number EZC250F3250, quantity and required delivery time.
  • System voltage, frequency and earthing arrangement.
  • Calculated prospective short-circuit current at the board.
  • Load current, cable size and number of poles needed.
  • Board maker, enclosure type and site ambient temperature.
  • Photo of the nameplate if you are replacing an existing breaker.

EZC250F3250 technical specifications

Parameter Specification
Manufacturer / part number Schneider Electric / EZC250F3250
Range EasyPact EZC
Product type Circuit breaker
Device short name EZC250F
Poles / protected poles 3P / 3t
Network type AC and DC
Network frequency 50/60 Hz
Rated current [In] 250 A at 40 °C
Trip unit TM-D, thermal-magnetic
Trip unit rating 250 A at 50 °C
Protection type overload protection and short-circuit protection and excluding vat, fca jabal ali & are subject to change – check with your local distributor. and 8 nov 2026 1
Rated insulation voltage [Ui] 690 V AC 50/60 Hz
Rated impulse withstand [Uimp] 6 kV
Rated operational voltage [Ue] 550 V AC 50/60 Hz / 250 V DC
Breaking capacity code F
Suitability for isolation Yes
Utilisation category Category A
Control type Toggle
Mounting mode / support Fixed / Backplate
Connection pitch 35 mm
Local signalling Positive contact indication
Mechanical durability 10000 cycles
Dimensions 165 mm (H) x 105 mm (W) x 60 mm (D)
Standards EN/IEC 60947-2, GB/T 14048.2, EN/IEC 60947-1
IP / IK degree IP20 / IK07
Ambient temperature (operation) -25 to 70 °C
Ambient temperature (storage) -35 to 85 °C
Warranty 18 months

Selection checklist before ordering

The EZC250F3250 is typically specified for the main incomer of a medium board or a rising-main tap-off, using the full 250 A of the frame. Before you order, run through these points.

  • Design current and cable: the 250 A trip rating must sit above the design current and below the cable’s current-carrying capacity at site temperature.
  • Fault level: compare the Icu at your system voltage (15 kA at 400/415 V AC) with the calculated prospective short-circuit current, and keep the Ics in mind for the duty you expect.
  • Number of poles: 3P on this reference. A separate neutral link or a four-pole version is needed where the neutral must be switched.
  • Short-circuit trip: the trip unit is a fixed TM-D unit; the datasheet gives no adjustable thresholds for this reference.
  • Space: allow 165 mm (H) x 105 mm (W) x 60 mm (D) and a connection pitch of 35 mm.
  • Supply type: the datasheet lists AC and DC, with a rated operational voltage of 550 V AC 50/60 Hz / 250 V DC.

Installation, commissioning and maintenance

Backplate mounting with front connections is the only arrangement the datasheet gives for the EZC250F3250, which keeps installation simple but leaves little room to change the arrangement later.

Make the connections to lugs or bars that suit the 35 mm pitch and follow the torque values in the installation sheet. After energising, check the handle and the terminal temperature under load, because a loose connection is the usual cause of a hot spot or nuisance trip.

The trip unit has no setting to adjust, so commissioning is verification. Exercise the handle now and then and inspect the case and terminals; a breaker that has cleared a fault near its Icu should be inspected or replaced. Durability in the datasheet: 10000 cycles mechanical, see datasheet electrical.

Breaking capacity by voltage: Icu and Ics in the datasheet

Breaking capacity is the figure that decides whether a breaker may sit at a given point in the network. Icu is the ultimate breaking capacity, the highest fault current the breaker can interrupt, after which it may no longer be fit for service. Ics is the service breaking capacity, a fraction of Icu that the breaker can interrupt and still carry on working. The datasheet of the EZC250F3250 gives both, by voltage, as follows.

Voltage (V) Icu Ics
110/130 V AC 50/60 Hz 25 kA 12.5 kA
220/240 V AC 50/60 Hz 25 kA –
220/230/240 V AC 50/60 Hz – 12.5 kA
380 V AC 50/60 Hz 18 kA 9 kA
400/415 V AC 50/60 Hz 15 kA 9 kA
440 V AC 50/60 Hz 10 kA 7.5 kA
550 V AC 50/60 Hz 5 kA 2.5 kA
125 V DC 5 kA 2.5 kA
250 V DC 5 kA 2.5 kA

At the usual 400/415 V AC level the EZC250F3250 is listed with an Icu of 15 kA. That is the lower of the three classes in the 250 A frame, which makes it a fit for boards fed from a modest transformer or from a long cable run where fault level has already dropped.

How this breaker compares with its siblings

The table compares the EZC250F3250 with references of the same frame group that Seven Star LLC can quote. These are datasheet values only; other ratings and frames exist.

Reference Frame Poles Rated current Trip rating Icu at 400/415 V
EZC250F3125 EZC250F 3P 125 A 125 A 15 kA
EZC250F3160 EZC250F 3P 160 A 160 A 15 kA
EZC250F3200 EZC250F 3P 200 A 200 A 15 kA
EZC250F3250 EZC250F 3P 250 A 250 A 15 kA

Within one frame the case dimensions are the same from rating to rating, but a change of class or frame needs a check of the busbar connection and the door cut-out.

Documents and quotation

The manufacturer datasheet for EZC250F3250 is attached on this page, so you can compare the figures quoted here with the original before you commit to a design or a purchase order.

To proceed, send the part number, the quantity and a few lines about the installation and we will reply with availability and a quotation. Seven Star LLC works as an independent supplier in Muscat with no affiliation to the manufacturer.

Datasheets & Documents
  • PDF Datasheet Schneider Electric EZC250F3250 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric EZC250F3250 EZC250F 250A 3P MCCB

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the EZC250F3250?
The datasheet lists a rated current [In] of 250 A at 40 °C and a trip unit rating of 250 A at 50 °C. The breaker is a fixed thermal-magnetic TM-D unit, so these values are not adjustable.
02What is the breaking capacity of the EZC250F3250 at 400/415 V AC?
The datasheet gives an Icu of 15 kA at 400/415 V AC (or the nearest listed range). Always compare it with the prospective short-circuit current at your busbar.
03How many poles does the EZC250F3250 have?
It is a 3P breaker with the protected poles listed as 3t. No neutral pole is fitted.
04What are the dimensions of the EZC250F3250?
The datasheet gives 165 mm (H) x 105 mm (W) x 60 mm (D) with a connection pitch of 35 mm and front connections.
05Can the EZC250F3250 be used on DC?
The datasheet lists AC and DC network types with a DC operational voltage of 250 V DC, with Icu given per pole configuration in the table above.