Schneider Electric EZ9R36263 Easy9 2P 63 A 30 mA RCCB
Description
EZ9R36263: Easy9 2P 63 A 30 mA type AC RCCB
The EZ9R36263 is a Schneider Electric Easy9 residual current circuit breaker (RCCB): two-pole, opens phase and neutral together, for a single-phase circuit. Its rated current is 63 A, its earth-leakage sensitivity is 30 mA with instantaneous tripping, and the protection class is type AC. It clips onto a DIN rail, occupies 4 modules of 9 mm (36 mm) and is rated 230 V AC at 50/60 Hz. Seven Star LLC supplies the EZ9R36263 in Oman and the GCC as an independent supplier based in Muscat.
The reference reads as EZ9R, then 3 for 30 mA, then 6, then 2 for the pole count and 63 for the rated current in amperes. That is our reading of the pattern across the twelve Easy9 RCCB references we looked at, not a published ordering table, so confirm the complete reference before you order.
Technical specifications of the EZ9R36263
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / EZ9R36263 |
| Range | Easy9 |
| Product type | Residual current circuit breaker (RCCB) |
| Device short name | Easy9 RCCB |
| Poles | 2P |
| Neutral position | Left |
| Rated current [In] | 63 A |
| Earth-leakage sensitivity | 30 mA |
| Protection time delay | Instantaneous |
| Protection class | Type AC |
| Network / frequency | AC / 50/60 Hz |
| Rated operational voltage [Ue] | 230 V AC 50/60 Hz |
| Rated insulation voltage [Ui] | 440 V AC |
| Rated impulse withstand [Uimp] | 4 kV |
| Surge current | 250 A |
| Rated breaking and making capacity | 500 A |
| Rated conditional short-circuit current | Easy9 MCB: 6000 A 63 A |
| Residual current tripping | Voltage independent |
| Device location in system | Outgoer |
| Control / indication | Toggle; contact position indicator |
| Mounting | Clip-on, DIN rail |
| Comb busbar compatibility | Top: yes |
| Connection pitch | 18 mm between phases |
| Width | 36 mm (4 × 9 mm pitches) |
| Height / depth | 82 mm / 72 mm |
| Colour | Grey (RAL 7035) |
| Terminals | Tunnel type, top or bottom: 1–35 mm² rigid; 1–25 mm² flexible |
| Tightening torque | 3.5 N.m, top or bottom |
| Mechanical / electrical durability | 5000 cycles / AC 2000 cycles at 230 V AC 50/60 Hz |
| Standard | IEC 61008-1 |
| Certification | CE |
| Degree of protection | IP20 |
| Pollution degree | 2 (IEC 61008-1) |
| Tropicalisation | 2 |
| Relative humidity | 95 % at 55 °C |
| Operating temperature | -5 to 60 °C |
| Storage temperature | -40 to 85 °C |
| Packing | 1 piece, 211 g; 6 pieces in the second package level |
| Warranty | 18 months |
How the EZ9R36263 detects earth leakage
Inside an RCCB the live conductors pass through a sensing core. When current out and current back are equal the core sees nothing, and when part of it leaves by another path, such as through a person or a damaged cable to earth, the imbalance appears. At 30 mA the EZ9R36263 opens all 2 poles. The datasheet lists voltage-independent tripping, so the mechanism does not rely on the line voltage to act.
The device is type AC, which responds to sinusoidal alternating residual current. Loads that can put a smooth or pulsating DC component into a fault, such as some drives, chargers and rectifier supplies, need a type A or better device, and the protection class on this reference should be compared with those loads before it is chosen.
An RCCB gives no overload or short-circuit protection. The datasheet figure for conditional short-circuit current assumes the proper protective device ahead of the EZ9R36263, which should not be rated above 63 A.
Why 30 mA on the EZ9R36263
The EZ9R36263 has a 30 mA threshold, the figure normally associated with supplementary protection of people on socket and final circuits. All leakage downstream adds up, including the small leakage that filters and electronic supplies send to earth, so a board with many such loads on one RCCB can drift toward the trip level. Splitting circuits across several RCCBs, or moving to a less sensitive stage where the protection goal allows it, is the usual remedy.
Instantaneous tripping, as listed here, means there is no built-in delay. When several residual current devices are cascaded, a downstream fault can trip the upstream device at the same time unless it is a selective type, so plan the board structure with that in mind.
Durability and environment for the EZ9R36263
The datasheet lists 5000 mechanical cycles and 2000 electrical cycles at 230 V AC, IP20 protection, pollution degree 2, tropicalisation 2 and 95 % relative humidity at 55 °C. Operation is listed from -5 to 60 °C and storage from -40 to 85 °C.
The upper operating limit of 60 °C is well above typical indoor room air, but a closed board in an Omani summer runs hotter than the room, so leave ventilation and distance from contactors and busbars around this RCCB.
Installing and testing the EZ9R36263
Isolate and prove dead, clip the this RCCB onto the DIN rail, connect the conductors observing the neutral position and tighten to 3.5 N.m. After energising, operate the test button on the front. The device must trip immediately, and the toggle is then reset by hand. A device that does not trip on test should be replaced instead of reset.
Operate the test button at regular intervals in service and record the rating and sensitivity on the board schedule. When an RCCB trips for real, look for the leakage before closing it again, because a repeated trip normally points to wet equipment, a damaged cable or an earth fault.
The EZ9R36263 among Easy9 RCCBs
Pole count sets the width and the voltage, the current rating sets how much load the device can carry, and sensitivity sets the leakage level at which it trips. The table compares neighbouring Easy9 references.
| Part number | Poles | Rated current | Sensitivity | Width | Voltage |
|---|---|---|---|---|---|
| EZ9R36240 | 2P | 40 A | 30 mA | 36 mm | 230 V AC |
| EZ9R36263 (this page) | 2P | 63 A | 30 mA | 36 mm | 230 V AC |
| EZ9R36440 | 4P | 40 A | 30 mA | 72 mm | 400 V AC |
| EZ9R36463 | 4P | 63 A | 30 mA | 72 mm | 400 V AC |
| EZ9R56240 | 2P | 40 A | 100 mA | 36 mm | 230 V AC |
| EZ9R56263 | 2P | 63 A | 100 mA | 36 mm | 230 V AC |
| EZ9R66263 | 2P | 63 A | 300 mA | 36 mm | 230 V AC |
Selection checklist for the EZ9R36263
- Supply: 230 V AC, 2 poles, matching a single-phase circuit.
- Current: load through the device up to 63 A, with upstream protection no higher.
- Sensitivity: 30 mA against the goal of protecting people, equipment or the installation from fire.
- Waveform: type AC against the loads on the circuit.
- Backup: a miniature circuit breaker or fuse upstream, since the RCCB does not trip on overcurrent.
- Space: 4 modules, 36 mm of DIN rail.
Information to send with an RFQ for the EZ9R36263
- Exact reference EZ9R36263 and the quantity needed.
- Supply voltage, system type and earthing arrangement.
- Description of the loads, including drives or electronic equipment.
- Upstream protective device and its rating.
- Other poles, ratings or sensitivities needed in the same order.
- Delivery location and timeline.
Before ordering, check that the board enclosure, busbar arrangement and neighbouring devices leave enough room for heat to escape, since crowded boards in hot rooms run closer to their limits than the rated ambient suggests.
Keep a record of the installed ratings on the board schedule and note the supply voltage at commissioning, because later extensions and fault investigations depend on knowing exactly what protects each circuit.
Spare devices of the same rating, pole count and sensitivity are worth planning for sites that run continuously, since a like-for-like replacement keeps the original protection design intact after a trip or a fault.
If the board will be extended later, leave spare rail length and think about how added circuits change the leakage current seen by this device, which affects how close it runs to its trip threshold.
Documents and quotation
The Schneider Electric datasheet for the EZ9R36263 is attached on this page and holds the full specification summarised above. It is dated 8 Nov 2026 as printed on the manufacturer’s document.
Send us the reference EZ9R36263, quantity and delivery location and Seven Star LLC will reply to your request. We supply as an independent supplier based in Muscat and do not act for the manufacturer.
Other Models in the Se Easy9 Rccb Range
Seven Star LLC supplies models from the Se Easy9 Rccb range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric EZ9R36240 Easy9 2P 40 A 30 mA RCCB | Circuit Breakers | View details |
| Schneider Electric EZ9R36263 Easy9 2P 63 A 30 mA RCCB | Circuit Breakers | You are viewing this model |
Datasheets & Documents
- Datasheet Schneider Electric EZ9R36263 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric EZ9R36263 Easy9 2P 63 A 30 mA
Answers from our engineering team on installation, compatibility and integration.
01What does the EZ9R36263 protect against?
It is a 2-pole type AC RCCB with 30 mA sensitivity and instantaneous tripping. It trips on earth-leakage current but gives no overload or short-circuit protection, so a breaker or fuse of no more than 63 A should be fitted upstream.
02What supply is the EZ9R36263 rated for?
The datasheet lists 230 V AC at 50/60 Hz with 2 poles and a rated current of 63 A. The datasheet gives the conditional short-circuit current as Easy9 MCB: 6000 A at 63 A, and a rated breaking and making capacity of 500 A.
03What size does the EZ9R36263 have?
It is 36 mm wide, 82 mm high and 72 mm deep, which is 4 modules of 9 mm, and it clips onto a DIN rail.
04What conductors fit the EZ9R36263 terminals?
The tunnel terminals at the top and bottom take 1 to 35 mm2 rigid and 1 to 25 mm2 flexible conductors, tightened to 3.5 N.m.
05What temperature range is listed for the EZ9R36263?
Operation is listed from -5 to 60 degrees C and storage from -40 to 85 degrees C, with IP20 protection and 5000 mechanical cycles.