- Automation & ControlView all 2,807 products
- Automation Accessories
- AC Drives
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- Safety Switches & Guard Locking
- Motor Soft Starters
- CCTV & Security
- Encoders
- Pneumatic Cylinders
- HMI Displays
- Servo Drives
- Industrial Computers
- Machine Vision
- Automation Software
- Robotics
Brand: Schneider Electric
Schneider Electric DBV348NSF DBSeT 48-Way Flush Board 250A
Description
DBV348NSF: 48-way DBSeT flush-mount distribution board, 250 A
The DBV348NSF is a Schneider Electric DBSeT three-phase distribution board with 48 outgoer ways, a rated current of 250 A and a flush-mounted white steel enclosure. The product title in the manufacturer catalogue describes it as a VTPN board with 48 modules, a 250 A NSX incomer and IP41 protection. Seven Star LLC supplies it as an independent supplier in Oman and the GCC for panel builders, electrical contractors and maintenance teams that need a ready enclosure with the busbar pan already fitted.
The reference carries no published decoding table in the datasheet, so the reading below comes from the descriptive title only: the board is the NSX-incomer version, in flush mounting, with 48 ways. The datasheet lists the pan assembly, earthing bar, neutral bar and enclosure as the equipment provided; circuit breakers are not part of that list, so DBV348NSF should be treated as an empty board to be populated with your own incomer and outgoer devices.
Ratings, short-circuit data and incomer choice for the DBV348NSF
The board is rated 250 A at 220–440 V AC, 50/60 Hz on a three-phase network, with a rated insulation voltage of 500 V AC and an impulse withstand of 6 kV. Short-circuit strength is stated as 25 kA for 0.3 s for the short-time current and 52.5 kA for the peak value. These figures describe the assembly itself; the real fault level at your installation must still be coordinated with the upstream protection and with the breaking capacity of every device you fit.
Because this is the NSX-incomer version, the incoming device is a molded case circuit breaker, which is the option the datasheet lists for the 250 A rating. That makes the board suitable for a feeder where adjustable protection or higher fault duty is wanted at the head of the board rather than a simple isolator. Outgoers on the datasheet are miniature circuit breakers or RCBOs, so earth-leakage protection can be applied per circuit instead of per group.
Typical applications of the DBV348NSF in Oman and the GCC
A board of this size is normally installed as a sub-distribution point inside buildings: larger apartment floors, clinics and school wings that need an MCCB at the head of the board. In Oman and the wider GCC the main design pressures are high ambient temperature, split air-conditioning loads that start together, and long cable runs from a central switchroom. The 500 V AC insulation rating and 6 kV impulse withstand give the assembly a reasonable margin for these supplies, and the RCBO option helps keep one faulty circuit from taking out a whole floor.
Contractors in Muscat, Sohar and Salalah usually combine such boards with other Schneider Electric modular devices, but any compatible protective device can be selected provided it fits the rails and the ratings above. Because the DBV348NSF is IP41 only, boards in dusty plant areas should be placed inside a room, not on an open wall.
Selection checklist for the DBV348NSF
- Confirm the demand: total connected load and diversity should stay within 250 A at the board.
- Choose the incomer: a molded case circuit breaker of suitable rating and trip unit; the device is bought separately.
- Count circuits: 48 outgoer ways, and leave spare ways for future loads.
- Check fault level: the datasheet gives 25 kA for 0.3 s and 52.5 kA for the assembly.
- Check supply: 220–440 V AC, 50/60 Hz three-phase, and confirm neutral and earthing arrangement.
- Decide mounting early: flush, with a board size of 425 × 975 × 147.9 mm.
- Verify the room environment is dry indoor, matching IP41 and IK08.
Technical specifications of the DBV348NSF
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / DBV348NSF |
| Range | DBSeT |
| Product type | Distribution board, distribution enclosure |
| Application | Low voltage electrical distribution |
| Number of ways | 48 ways (outgoer) |
| Rated current [In] | 250 A |
| Rated short-time withstand [Icw] | 25 kA for 0.3 s |
| Rated peak withstand [Ipk] | 52.5 kA |
| Rated impulse withstand [Uimp] | 6 kV |
| Rated insulation voltage [Ui] | 500 V AC |
| Rated voltage | 220–440 V AC, 50/60 Hz |
| Network | 3 phases |
| Protection device options | MCCB as incomer; MCB or RCBO as outgoers |
| Enclosure mounting | Flush |
| Door | Plain flat door |
| Cable entry | Removable gland plate at top and bottom |
| Material | Painted sheet steel, 1.2 mm thick |
| Colour | White (RAL 9003) |
| Dimensions (W × H × D) | 425 × 975 × 147.9 mm |
| IP / IK rating | IP41 (IEC 60529) / IK08 |
| Ambient temperature, operation | 50 °C |
| Standards | IEC 61439-1, IEC 61439-3 |
| Certification | DEKRA |
| Provided equipment | Enclosure, pan assembly, earthing bar, neutral bar |
Flush mounting: what it means for the DBV348NSF
This reference is the flush version. The body is intended to be set into a wall recess with the door frame sitting close to the finished surface, which gives a tidy appearance in occupied buildings such as apartments, offices, clinics and schools. The wall must be prepared with a recess that matches the 975 mm height and 147.9 mm depth, so the decision has to be made at the civil stage, not after plastering.
The surface twin of the same board is DBV348NSS. Check that the chosen mounting style matches the drawings before ordering, because the enclosure dimensions for flush and surface versions are not interchangeable on site without rework.
Enclosure construction and cable entry on the DBV348NSF
The enclosure is made of painted sheet steel 1.2 mm thick, finished in white RAL 9003, with a plain flat door. External size is 425 mm wide by 975 mm high by 147.9 mm deep. Protection is IP41 against solid objects and dripping water per IEC 60529 and IK08 against impact, which fits dry indoor rooms; it is not a washdown or outdoor rating.
Cables enter through removable gland plates at the top and the bottom, so the installer can drill or punch the plates on the bench and refit them. Plan the routing early: with 48 outgoer ways and a 147.9 mm deep body, the space behind the devices is limited, and large cable bundles should be dressed to one side. The standards listed for the board are IEC 61439-1 and IEC 61439-3, the latter covering distribution boards operated by ordinary persons, and the certification line shows DEKRA.
How the DBV348NSF compares with related DBSeT boards
The DBSeT VTPN boards in this group differ in outgoer count, incomer type, mounting and enclosure size. The table lists the references covered by our pages, with height and depth taken from each datasheet (width is 425 mm for all of them). Related references such as DBV348NSS, DBV348MF and DBV354NSF are siblings in the same line.
| Reference | Ways | Incomer | Mounting | H × D |
|---|---|---|---|---|
| DBV348MF | 48 | 125 A modular | Flush | 785 × 124.9 mm |
| DBV348MS | 48 | 125 A modular | Surface | 785 × 124.9 mm |
| DBV348NSF | 48 | 250 A MCCB (NSX) | Flush | 975 × 147.9 mm |
| DBV348NSS | 48 | 250 A MCCB (NSX) | Surface | 975 × 147.9 mm |
| DBV354MF | 54 | 125 A modular | Flush | 830 × 124.9 mm |
| DBV354NSF | 54 | 250 A MCCB (NSX) | Flush | 975 × 147.9 mm |
Note that the 250 A boards share one enclosure size whether they carry 48 or 54 ways, while the 125 A boards grow in height from 785 mm to 830 mm when the way count rises.
Information to send with an RFQ for the DBV348NSF
- Exact reference DBV348NSF and the quantity.
- Incomer type and rating, and outgoer breaker types and counts.
- Short-circuit level at the installation point.
- Delivery location in Oman or the GCC and the project schedule.
- Whether neutral link and earth bar extras are needed.
Documents and quotation
The manufacturer datasheet for the DBV348NSF is attached on this page and contains the full specification summarised above. Check the revision date against your project before relying on it.
Send us the reference DBV348NSF, the quantity and your delivery location, and Seven Star LLC will reply to your request. We are an independent supplier based in Muscat and do not act on behalf of the manufacturer.
Other Models in the Se Dbset Vtpn Range
Seven Star LLC supplies models from the Se Dbset Vtpn range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Schneider Electric DBV348MF DBSeT 48-Way Flush Board 125A | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric DBV348MS DBSeT 48-Way Surface Board 125A | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric DBV348NSF DBSeT 48-Way Flush Board 250A | Switchgear, Enclosures & Distribution | You are viewing this model |
| Schneider Electric DBV348NSS DBSeT 48-Way Surface Board 250A | Switchgear, Enclosures & Distribution | View details |
| Schneider Electric DBV354MF DBSeT 54-Way Flush Board 125A | Switchgear, Enclosures & Distribution | View details |
Datasheets & Documents
- Datasheet Schneider Electric DBV348NSF Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric DBV348NSF DBSeT 48-Way Flush
Answers from our engineering team on installation, compatibility and integration.
01What is the rated current of the DBV348NSF?
The datasheet lists a rated current of 250 A on a three-phase network at 220-440 V AC, 50/60 Hz. Rated insulation voltage is 500 V AC and impulse withstand is 6 kV.
02How many ways does the DBV348NSF have?
It has 48 outgoer ways. Outgoers can be miniature circuit breakers or RCBOs, and the incomer is molded case circuit breaker incomer (NSX class).
03Are circuit breakers included with the DBV348NSF?
The datasheet lists the enclosure, pan assembly, earthing bar and neutral bar as provided equipment. Breakers are not in that list, so the incomer and outgoers are ordered separately.
04What are the dimensions and mounting of the DBV348NSF?
It is a flush-mounted steel board measuring 425 mm wide, 975 mm high and 147.9 mm deep, finished in white RAL 9003.
05What protection rating does the DBV348NSF have?
The enclosure is rated IP41 per IEC 60529 and IK08. The listed standards are IEC 61439-1 and IEC 61439-3 and the certification shown is DEKRA.


















Reviews
There are no reviews yet.