Schneider Electric DBV348MS DBSeT 48-Way Surface Board 125A

Description

DBV348MS: 48-way DBSeT surface-mount distribution board, 125 A

The DBV348MS is a Schneider Electric DBSeT three-phase distribution board with 48 outgoer ways, a rated current of 125 A and a surface-mounted white steel enclosure. The product title in the manufacturer catalogue describes it as a VTPN board with 48 modules, a 125 A modular incomer and IP41 protection. Seven Star LLC supplies it as an independent supplier in Oman and the GCC for panel builders, electrical contractors and maintenance teams that need a ready enclosure with the busbar pan already fitted.

The reference carries no published decoding table in the datasheet, so the reading below comes from the descriptive title only: the board is the modular-incomer version, in surface mounting, with 48 ways. The datasheet lists the pan assembly, earthing bar, neutral bar and enclosure as the equipment provided; circuit breakers are not part of that list, so DBV348MS should be treated as an empty board to be populated with your own incomer and outgoer devices.

How the DBV348MS compares with related DBSeT boards

The DBSeT VTPN boards in this group differ in outgoer count, incomer type, mounting and enclosure size. The table lists the references covered by our pages, with height and depth taken from each datasheet (width is 425 mm for all of them). Related references such as DBV348MF, DBV348NSS and DBV354MF are siblings in the same line.

Reference Ways Incomer Mounting H × D
DBV348MF 48 125 A modular Flush 785 × 124.9 mm
DBV348MS 48 125 A modular Surface 785 × 124.9 mm
DBV348NSF 48 250 A MCCB (NSX) Flush 975 × 147.9 mm
DBV348NSS 48 250 A MCCB (NSX) Surface 975 × 147.9 mm
DBV354MF 54 125 A modular Flush 830 × 124.9 mm
DBV354NSF 54 250 A MCCB (NSX) Flush 975 × 147.9 mm

Note that the 250 A boards share one enclosure size whether they carry 48 or 54 ways, while the 125 A boards grow in height from 785 mm to 830 mm when the way count rises.

Selection checklist for the DBV348MS

  • Confirm the demand: total connected load and diversity should stay within 125 A at the board.
  • Choose the incomer: isolator, RCCB or isolator plus RCCB; the device is bought separately.
  • Count circuits: 48 outgoer ways, and leave spare ways for future loads.
  • Check fault level: the datasheet gives 17 kA for 0.25 s and 34 kA for the assembly.
  • Check supply: 240–415 V AC, 50/60 Hz three-phase, and confirm neutral and earthing arrangement.
  • Decide mounting early: surface, with a board size of 425 × 785 × 124.9 mm.
  • Verify the room environment is dry indoor, matching IP41 and IK08.

Surface mounting: what it means for the DBV348MS

This reference is the surface version. The enclosure is fixed on the face of the wall, so no recess is required and the board can be added to an existing room, a plant room or a service corridor with little disturbance to the structure. Allow clearance in front for the door swing and keep the top and bottom gland plates reachable for later cable additions.

The flush twin of the same board is DBV348MF (48 ways, 125 A). Check that the chosen mounting style matches the drawings before ordering, because the enclosure dimensions for flush and surface versions are not interchangeable on site without rework.

Installation and maintenance notes for the DBV348MS

Fit the enclosure level, run the incoming feeder through the top or bottom gland plate, and mount the incomer and outgoer devices on the rails supplied in the pan assembly. Connect the earthing bar and the neutral bar first, then label each way so that later maintenance does not rely on memory. Tighten all terminals to the torque stated in the data of the devices you install, and fit blanking covers on any unused ways to keep the front accessible only through intended openings.

After commissioning, record insulation and loop-impedance results, and test every RCBO or RCCB with its test button on a routine schedule. In coastal Gulf sites the main cleaning concern is dust and salt film on the door and gland plates; wipe the painted surface with a soft cloth and keep the door closed during works nearby. The datasheet gives an ambient operating figure of 50 °C, so avoid placing DBV348MS beside heat sources such as unventilated transformer cubicles.

Enclosure construction and cable entry on the DBV348MS

The enclosure is made of painted sheet steel 1.2 mm thick, finished in white RAL 9003, with a plain flat door. External size is 425 mm wide by 785 mm high by 124.9 mm deep. Protection is IP41 against solid objects and dripping water per IEC 60529 and IK08 against impact, which fits dry indoor rooms; it is not a washdown or outdoor rating.

Cables enter through removable gland plates at the top and the bottom, so the installer can drill or punch the plates on the bench and refit them. Plan the routing early: with 48 outgoer ways and a 124.9 mm deep body, the space behind the devices is limited, and large cable bundles should be dressed to one side. The standards listed for the board are IEC 61439-1 and IEC 61439-3, the latter covering distribution boards operated by ordinary persons, and the certification line shows DEKRA.

Ratings, short-circuit data and incomer choice for the DBV348MS

The board is rated 125 A at 240–415 V AC, 50/60 Hz on a three-phase network, with a rated insulation voltage of 500 V AC and an impulse withstand of 6 kV. Short-circuit strength is stated as 17 kA for 0.25 s for the short-time current and 34 kA for the peak value. These figures describe the assembly itself; the real fault level at your installation must still be coordinated with the upstream protection and with the breaking capacity of every device you fit.

Because this is the modular-incomer version, the incoming device is a DIN-rail unit. The datasheet allows an isolator, a residual current circuit breaker, or an isolator combined with an RCCB at the incomer, which suits final distribution where the upstream feeder is already protected. Outgoers on the datasheet are miniature circuit breakers or RCBOs, so earth-leakage protection can be applied per circuit instead of per group.

Technical specifications of the DBV348MS

Parameter Specification
Manufacturer / part number Schneider Electric / DBV348MS
Range DBSeT
Product type Distribution board, distribution enclosure
Application Low voltage electrical distribution
Number of ways 48 ways (outgoer)
Rated current [In] 125 A
Rated short-time withstand [Icw] 17 kA for 0.25 s
Rated peak withstand [Ipk] 34 kA
Rated impulse withstand [Uimp] 6 kV
Rated insulation voltage [Ui] 500 V AC
Rated voltage 240–415 V AC, 50/60 Hz
Network 3 phases
Protection device options Isolator, RCCB, or isolator plus RCCB as incomer; MCB or RCBO as outgoers
Enclosure mounting Surface
Door Plain flat door
Cable entry Removable gland plate at top and bottom
Material Painted sheet steel, 1.2 mm thick
Colour White (RAL 9003)
Dimensions (W × H × D) 425 × 785 × 124.9 mm
IP / IK rating IP41 (IEC 60529) / IK08
Ambient temperature, operation 50 °C
Standards IEC 61439-1, IEC 61439-3
Certification DEKRA
Provided equipment Enclosure, pan assembly, earthing bar, neutral bar

Information to send with an RFQ for the DBV348MS

  • Exact reference DBV348MS and the quantity.
  • Incomer type and rating, and outgoer breaker types and counts.
  • Short-circuit level at the installation point.
  • Delivery location in Oman or the GCC and the project schedule.
  • Whether neutral link and earth bar extras are needed.

Documents and quotation

The manufacturer datasheet for the DBV348MS is attached on this page and contains the full specification summarised above. Check the revision date against your project before relying on it.

Send us the reference DBV348MS, the quantity and your delivery location, and Seven Star LLC will reply to your request. We are an independent supplier based in Muscat and do not act on behalf of the manufacturer.

Other Models in the Se Dbset Vtpn Range

Seven Star LLC supplies models from the Se Dbset Vtpn range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric DBV348MF DBSeT 48-Way Flush Board 125ASwitchgear, Enclosures & DistributionView details
Schneider Electric DBV348MS DBSeT 48-Way Surface Board 125ASwitchgear, Enclosures & DistributionYou are viewing this model
Schneider Electric DBV348NSF DBSeT 48-Way Flush Board 250ASwitchgear, Enclosures & DistributionView details
Schneider Electric DBV348NSS DBSeT 48-Way Surface Board 250ASwitchgear, Enclosures & DistributionView details
Schneider Electric DBV354MF DBSeT 54-Way Flush Board 125ASwitchgear, Enclosures & DistributionView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric DBV348MS Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric DBV348MS DBSeT 48-Way Surface

Answers from our engineering team on installation, compatibility and integration.

01What is the rated current of the DBV348MS?
The datasheet lists a rated current of 125 A on a three-phase network at 240-415 V AC, 50/60 Hz. Rated insulation voltage is 500 V AC and impulse withstand is 6 kV.
02How many ways does the DBV348MS have?
It has 48 outgoer ways. Outgoers can be miniature circuit breakers or RCBOs, and the incomer is modular incomer (isolator or residual current circuit breaker).
03Are circuit breakers included with the DBV348MS?
The datasheet lists the enclosure, pan assembly, earthing bar and neutral bar as provided equipment. Breakers are not in that list, so the incomer and outgoers are ordered separately.
04What are the dimensions and mounting of the DBV348MS?
It is a surface-mounted steel board measuring 425 mm wide, 785 mm high and 124.9 mm deep, finished in white RAL 9003.
05What protection rating does the DBV348MS have?
The enclosure is rated IP41 per IEC 60529 and IK08. The listed standards are IEC 61439-1 and IEC 61439-3 and the certification shown is DEKRA.