Schneider Electric DBR116MS DBSeT 16-way 100 A board

Description

DBR116MS: DBSeT 16-way surface mount distribution board

The DBR116MS is a Schneider Electric DBSeT low-voltage distribution board in painted white sheet steel, rated 100 A and arranged with one DIN rail with 16 modules of 18 mm. The datasheet lists the type as a distribution board for low-voltage electrical distribution, supplied as an enclosure with DIN rail and an identification label, for surface installation. Seven Star LLC supplies the DBR116MS in Oman and the GCC as an independent supplier based in Muscat.

How to read DBR116MS: DBR is the board series, 1 stands for the number of rows, 16 for the modules per row, and the final letters MF or MS follow the mounting style. The datasheet title for this reference reads “16 ways, 100A, 1 row, surface mount”, and we have followed the title wording rather than a published ordering table.

Surface mounting and what it means for DBR116MS

The surface version is fixed on the face of the wall, which makes it the practical choice for retrofit work, for masonry or partition walls that cannot be chased, and for service rooms where the board remains visible and accessible.

The datasheet gives the same outer dimensions of 425 x 295 x 124.9 mm for the this unit, so measure the wall opening or the wall face against those numbers and allow working room for the door to open. The plain flat door is fitted to a frame that carries the identification label, and the board earns its IP41 rating only when the door is closed and unused cable entries are covered.

Wiring and cable entry on DBR116MS

The datasheet lists a removable gland plate at top and bottom. That arrangement lets the installer drill or punch the plate away from the board and avoid metal swarf inside the live area. Use glands or conduit fittings that suit the cable and maintain the IP41 rating, and bond the metal enclosure and door to the protective earth according to the wiring rules.

Apply the identification label so each way can be traced, and keep a circuit schedule with the board. Unused ways should be covered with blanking pieces from the device range so that live parts are not accessible when the door is open.

Technical specifications of the DBR116MS

Parameter Specification
Manufacturer / part number Schneider Electric / DBR116MS
Range DBSeT
Type Distribution board, low-voltage electrical distribution
Rows / modules per row 1 / 16 modules of 18 mm
Rated current [In] 100 A
Rated voltage 240–415 V AC 50/60 Hz
Rated insulation voltage [Ui] 500 V AC
Mounting Surface
Door Plain flat door
Incomer options Isolator, MCB or RCCB, 100 A max
Outgoer options MCB 63 A max; RCBO 63 A max
Cable entry Removable gland plate at top and bottom
Material and colour Painted sheet steel 1.2 mm thick; white RAL 9003
Dimensions (W x H x D) 425 x 295 x 124.9 mm
Protection degrees IP41 (IEC 60529); IK08 (IEC 62262)
Operating temperature 50 °C
Standards IEC 61439-1, IEC 61439-3
Provided equipment Enclosure, DIN rail, identification label
Package weight 4.5 kg
Warranty 18 months

Where the DBR116MS is used in Oman and the GCC

Boards of this size appear in villas, apartments, offices, shops, small workshops and site cabins. In Oman and the GCC the main stress is heat: the datasheet gives an operating temperature of 50 °C, so a board in a hot plant room, a roof enclosure or a shaded corridor should be checked against that figure. Dust and humidity are other factors, and IP41 is for indoor use; outdoor or washdown locations call for a different enclosure type.

Sizing the DBR116MS: one row or two rows

Reference Rows Modules Mounting Height
DBR116MF 1 16 Flush 295 mm
DBR116MS 1 16 Surface 295 mm
DBR216MF 2 32 Flush 445 mm
DBR216MS 2 32 Surface 445 mm

The this unit has 16 modules. The single-row board is shallow in height and suits a small flat, an office or a utility closet. All four references share a width of 425 mm and the same 100 A rating, so the choice is about capacity and mounting style.

Selection checklist for DBR116MS

  • Count the modules of the incomer, outgoers and RCDs and compare with 16.
  • Check that the incomer is not above 100 A and the outgoers not above 63 A.
  • Confirm the surface mounting suits the wall construction.
  • Measure the opening or wall face against 425 x 295 x 124.9 mm.
  • Check the ambient temperature against the 50 °C listed.
  • Plan the entries on the top and bottom gland plates.
  • Confirm the standards required for the project, as the datasheet lists IEC 61439-1 and 61439-3.

Protective devices that fit the DBR116MS

The board is rated 100 A and accepts, according to the datasheet, an isolator, a miniature circuit-breaker or an RCCB of up to 100 A as incomer. As outgoers it accepts miniature circuit-breakers or RCBOs of up to 63 A. With 16 modules available on the DIN rail, a typical arrangement is an incomer plus a mixture of final circuits, some with earth-leakage protection.

A module count is not a circuit count: a two-pole or four-pole device uses several modules, and the incoming device also occupies space. Add up the device widths before settling on the this unit. Keep the total load inside the 100 A rating and apply diversity as the design standard allows.

Documents and quotation

The official Schneider Electric datasheet for this unit is attached on this page. It covers the figures used above, and the packaging and environmental data pages that a project file usually needs. The sibling references with a different row count or mounting can be quoted at the same time.

To receive a quotation, send the part number this unit, the quantity, the delivery location and any required documents. Seven Star LLC is an independent supplier in Muscat and replies with availability and lead time for Oman and the GCC.

Other Models in the Se Dbset Dbr Range

Seven Star LLC supplies models from the Se Dbset Dbr range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Schneider Electric DBR116MF DBSeT 16-way 100 A boardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBR116MS DBSeT 16-way 100 A boardSwitchgear, Enclosures & DistributionYou are viewing this model
Schneider Electric DBR216MF DBSeT 32-way 100 A boardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBR316MF DBSeT 48-Way 100A BoardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBR416MF DBSeT 64-Way 100A BoardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBR516MF DBSeT 80-Way 100A BoardSwitchgear, Enclosures & DistributionView details
Schneider Electric DBR616MF DBSeT 96-Way 100A BoardSwitchgear, Enclosures & DistributionView details
Datasheets & Documents
  • PDF Datasheet Schneider Electric DBR116MS Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.

Schneider Electric company profile

Origins 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry
Headquarters Rueil-Malmaison (Paris region), France
Ownership Public company listed on Euronext Paris
Key acquisitions Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software
Brand names still in use Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform
Product families Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software

Milestones

  • 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
  • 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
  • 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
  • 1997: Modicon, the company behind the first programmable logic controller, joins the group.
  • 1999: The group takes the name Schneider Electric.
  • 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.

Choosing Schneider Electric breakers and motor control

Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.

Where Schneider Electric products are used

In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.

APC by Schneider Electric: UPS and critical power

Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.

Schneider Electric products we list

Family Examples
Circuit breakers Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW
Motor control TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480
Drives Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo
PLCs, HMIs and relays Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655
Protection, metering and power Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS

Ordering Schneider Electric products: what we need

Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.

Facts checked against Schneider Electric's published company history, October 2026.

FAQ

Questions about the Schneider Electric DBR116MS DBSeT 16-way 100 A board

Answers from our engineering team on installation, compatibility and integration.

01How many ways does the DBR116MS have?
The datasheet lists 1 row(s) with 16 modules of 18 mm each, so 16 modules in total.
02What is the rating of the DBR116MS?
It is rated 100 A at 240–415 V AC 50/60 Hz, with a rated insulation voltage of 500 V AC. Incomers up to 100 A and outgoers up to 63 A are listed.
03Is the DBR116MS flush or surface mounted?
It is the surface mount version. The mounting style is the main difference to the sister reference with the other mounting suffix.
04What protection degrees does the DBR116MS have?
The datasheet lists IP41 under IEC 60529 and IK08 under IEC 62262, with IEC 61439-1 and IEC 61439-3 as standards.
05What are the dimensions of the DBR116MS?
The datasheet gives 425 mm wide, 295 mm high and 124.9 mm deep, in 1.2 mm painted sheet steel, white RAL 9003.