Schneider Electric BMXNOC0401 Modicon M340 Ethernet Network
Description
BMXNOC0401 EtherNet/IP and Modbus TCP network module
The BMXNOC0401 is a Schneider Electric product listed in the datasheet as: network module, Modicon M340, EtherNet/IP and Modbus/TCP, 4 x RJ45. The BMXNOC0401 is a network module for the Modicon M340 and X80 platform with four RJ45 ports, supporting EtherNet/IP and Modbus TCP. It extends the controller to remote devices and SCADA systems. Seven Star LLC supplies the BMXNOC0401 in Oman and the GCC as an independent supplier based in Muscat.
Reading the reference: NOC is the Ethernet network option card, 04 the port count and 01 the variant.
Technical specifications of the BMXNOC0401
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / BMXNOC0401 |
| Description | network module, Modicon M340, EtherNet/IP and Modbus/TCP, 4 x RJ45 |
| Range of Product | Modicon M340 automation platform |
| Product or Component Type | Ethernet TCP/IP network module |
| Concept | Transparent Ready |
| Integrated connection type | Ethernet RJ45 10/100 Mbit/s 4 twisted pairs transparent ready class B30 |
| Communication service | Bandwidth management; Data Editor (via PC terminal); FDR server; Rack Viewer; SNMP network administrator; Modbus TCP I/O Scanner and Messaging |
| Port Ethernet | 10BASE-T/100BASE-TX |
| Memory usage | Application saving; Activating the standard web server |
| Supply | Internal power supply via rack |
| Local signalling | 1 LED (green) for processor running (RUN); 1 LED (red) for processor or system fault (ERR) |
| Control Type | Processor or system fault (ERR) |
| Current consumption | 555 mA 3.3 V DC |
| Module format | Standard |
| Net Weight | 0.2 kg |
| Ambient air temperature (operation or storage, as listed) | 0 to 60 °C |
| Relative Humidity | 10 to 95 % without condensation |
| IP Degree of Protection | IP20 |
| Product certifications | CE; UL; CSA; RCM; EAC; Merchant Navy; ATEX zone 2/22; IECEx zone 2/22 |
| Standards | IEC 61131-2; IEC 61010-2-201; UL 61010-2-201; CSA C22.2 No 61010-2-201; IACS E10; IEC 61000-6-5, interface type 1 and type 2 |
| Environmental characteristic | Hazardous location class I division 2 |
Ports and protocols of the BMXNOC0401
Ethernet: 10BASE-T/100BASE-TX.
Four ports allow daisy-chain or star topology. The datasheet lists the services and limits.
Network planning for the BMXNOC0401
Segment the network between control and enterprise, use managed switches and document the IP plan. Compare with BMXNOE0100, an older Ethernet module.
Check firmware compatibility.
Selection checklist for the BMXNOC0401
- Ports and protocols.
- Rack slot.
- IP plan.
- Security.
- Firmware.
- Switch.
Configuration of the BMXNOC0401
Configure addresses in the programming software, test services and monitor diagnostics.
Store the configuration.
Typical applications of the BMXNOC0401 in Oman and the GCC
In Oman and the GCC it links process controllers to SCADA.
Dimensions, environment and approvals of the BMXNOC0401
The BMXNOC0401 weighs 0.2 kg. Mounting, derating and enclosure choices follow the environmental data below, which should be compared with the actual panel temperature and the dust and humidity of the site in Oman and the GCC.
Ambient temperature limits in the datasheet: 0 to 60 °C. Relative humidity: 10 to 95 % without condensation. Ingress protection: IP20. Standards listed: IEC 61131-2; IEC 61010-2-201; UL 61010-2-201; CSA C22.2 No 61010-2-201; IACS E10; IEC 61000-6-5, interface type 1 and type 2. Certifications listed for this reference: CE; UL; CSA; RCM; EAC; Merchant Navy; ATEX zone 2/22; IECEx zone 2/22.
Network modules are often blamed for faults that come from the network around them, so a structured approach helps with the BMXNOC0401. Start with the link LEDs on the four ports, then confirm addresses and subnet, then check the services running on the module. Use the diagnostic pages or the controller diagnostics to read the number of connections and the error counters; a growing error counter on one port points to a cable or switch problem. When the module is replaced, load the same configuration and confirm that the IP address and the device list are identical, otherwise the SCADA may refuse the connection. In larger systems, plan the use of the ports: one for the plant network, others for remote I/O or a redundant ring, as supported by the datasheet. Review the security settings with the IT team, switch off unused services and protect access to the configuration. In hot cabinets, keep airflow around the module, because network modules dissipate more heat than passive modules in the rack. A practical test before handover is a failover and recovery test: unplug one cable at a time while watching the diagnostics, then power-cycle the rack and confirm that all connections return without manual action. Record the time it takes, because a slow recovery after a power dip can show up as a nuisance alarm on the SCADA. Where several BMXNOC modules exist in the same plant, give each a clear name in the project and in the labels on the cabinet door so that a technician can tell them apart at a glance. Save the module configuration as a file and store it with the project on at least two independent media, and keep the firmware version in the same record.
Information to send with an RFQ for the BMXNOC0401
- Full reference and quantity required
- Existing equipment, panel or rack it must fit
- Supply voltage, load or signal details of the application
- Required delivery location and timing
- Whether a spare, a replacement or a new installation
Site conditions in Oman for the BMXNOC0401
Control cabinets in Gulf plants often run hot, because many sit in outdoor kiosks or in rooms where air conditioning is not always reliable. Before you finalise the BMXNOC0401, check the permitted ambient range and any derating stated by the manufacturer against the real temperature inside your panel, and leave the recommended spacing around the device so that heat can escape. Long cable runs between the field and the marshalling cabinet are common on large sites, so confirm the signal types, wiring limits and earthing arrangement early in the design.
It also helps to standardise on a small number of part numbers across a project. Keeping a few spare BMXNOC0401 units on site in Oman shortens recovery time after a fault, and documenting configuration settings makes replacement faster for the maintenance team.
Documents and quotation
A datasheet for this product is attached on this page. It lists the electrical, mechanical and environmental data summarised above.
Send us the part number, quantity and application and we will confirm availability and a quotation. Seven Star LLC is an independent supplier in Muscat and does not represent itself as an official channel of the manufacturer.
Datasheets & Documents
- Datasheet Schneider Electric BMXNOC0401 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric BMXNOC0401 Modicon M340 Ethernet
Answers from our engineering team on installation, compatibility and integration.
01What is the net weight of the BMXNOC0401?
The datasheet gives 0.2 kg.
02What ingress protection does the BMXNOC0401 list?
Stated as IP20.
03Which standards does the BMXNOC0401 list?
Listed: IEC 61131-2; IEC 61010-2-201; UL 61010-2-201; CSA C22.2 No 61010-2-201; IACS E10; IEC 61000-6-5, interface type 1 and type 2; IEC 61850-3, location G; IEC 60079-0.
04Which product range does the BMXNOC0401 belong to?
The datasheet lists the range as Modicon M340 automation platform.
05What certifications does the BMXNOC0401 list?
Listed: CE; UL; CSA; RCM; EAC; Merchant Navy; ATEX zone 2/22; IECEx zone 2/22.