Schneider Electric A9P52616 Acti9 iC40 1P + N 16 A C MCB
Description
A9P52616: Acti9 iC40 1P + N 16 A C-curve miniature circuit breaker
The A9P52616 is a Schneider Electric Acti9 iC40 miniature circuit-breaker, single-pole plus neutral, rated 16 A with a C curve and a thermal-magnetic trip unit. It is only 18 mm wide on the DIN rail (2 modules of 9 mm), which makes it a compact way to protect final circuits in a distribution board. Seven Star LLC supplies the A9P52616 in Oman and the GCC as an independent supplier based in Muscat.
The title of the reference reads as iC40 (the standard performance version of the iC40), 1P + N for the pole arrangement, 16 A for the rated current and C for the trip curve. This unit is used on single-phase circuits where the neutral is switched alongside the phase.
Technical specifications of the A9P52616
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Schneider Electric / A9P52616 |
| Range / product | Acti9 iC40 (device short name iC40) |
| Type | Miniature circuit-breaker, thermal-magnetic, distribution application |
| Poles | 1P + N, 1 protected pole(s); neutral position left |
| Rated current [In] | 16 A |
| Curve / magnetic trip | C curve; 5–10 × In (EN/IEC 60898-1), 8 × In ± 20 % (EN/IEC 60947-2) |
| Rated operational voltage | 230 V AC |
| Network type | AC |
| Breaking capacity | 6 kA Icu (EN/IEC 60947-2); 4500 A Icn at 230 V AC 50/60 Hz (EN/IEC 60898-1) |
| Service breaking capacity [Ics] | 100 % of Icn at 230 V AC 50/60 Hz |
| Limitation class | 3 |
| Isolation | Suitable for isolation |
| Rated insulation / impulse | Ui 400 V AC / Uimp 4 kV |
| Endurance (mechanical / electrical) | 20000 cycles / 20000 cycles |
| Dimensions (H × W × D) | 85 × 18 × 74 mm |
| Net weight | 120 g |
| Terminals | Tunnel type, top or bottom; 1–10 mm² flexible, 1–16 mm² rigid |
| Stripping length / torque | 14 mm / 2 N.m |
| Local signalling | ON/OFF indication, trip indicator |
| Locking | Padlocking device |
| Earth-leakage protection | Separate block |
| Ingress protection | IP20; IP40 in a modular enclosure |
| Operating / storage temperature | -25–70 °C / -40–85 °C |
| Humidity / altitude | 95 % at 55 °C / 2000 m |
| Standards | EN/IEC 60898-1, EN/IEC 60947-2 |
| Approvals listed | CE BV RINA DNV |
| Quality labels | KEMA and IMQ |
How the A9P52616 trips and what the curve means
A bimetal strip heats under sustained overcurrent and releases the contacts after a delay that shortens as current rises; an electromagnet releases almost instantly once the current passes the magnetic limit. For this unit the C curve places that limit at 5–10 times the rated current to EN/IEC 60898-1, or 8 times with a ± 20 % tolerance to EN/IEC 60947-2. At 16 A the device is the typical final-circuit size for lighting and small power in single-phase boards.
Selection checklist and RFQ details for the A9P52616
Check these points first.
- Poles: 1P + N; confirm the neutral is to be switched (yes).
- Rating and curve: 16 A, C curve, against the cable and load inrush.
- Fault level at the board against 6 kA Icu.
- Approvals: the project may need BV, RINA or DNV; all three appear in the datasheet.
- Add-on blocks and busbars: earth-leakage block, padlocking.
- Enclosure: IP20 alone, or IP40 inside a modular enclosure.
With your enquiry, send:
- Part number A9P52616 and quantity.
- Supply voltage, number of phases and prospective fault level.
- Delivery location and required date.
- Required approval certificates, if any.
How the A9P52616 compares with its siblings
The closest references in the same range are listed below for comparison. Same-range siblings share terminals and dimensions per pole; they differ in rating and breaking capacity.
| Part number | Version | Poles | Rating | Curve |
|---|---|---|---|---|
| A9P52632 | iC40 | 1P + N | 32 A | C |
The A9P52632 shares the 6 kA / 4.5 kA performance class and the same body, but its 32 A rating carries a lower electrical endurance figure of 10000 cycles.
Typical uses of the A9P52616 in Oman and the GCC
Single-pole plus neutral iC40 breakers are standard on residential, hotel and office final circuits, and on instrumentation and control supplies in industrial buildings. In the Gulf climate the listed operating range of -25–70 °C and 95 % humidity at 55 °C are suitable for most indoor panels, but a ventilated or air-conditioned room still extends life. The marine approvals in the datasheet also make it a candidate for vessel and offshore accommodation panels.
Breaking capacity and where it fits
The datasheet quotes 6 kA Icu and 4.5 kA Icn at 230 V AC. The standard iC40 sits below the N version in breaking capacity, so confirm the prospective short-circuit current at the board before choosing it. Service breaking capacity is listed at 100 % of Icn for the IEC 60898-1 rating, and the limitation class is 3, meaning a lower let-through energy than classes 1 and 2.
The approval list in the datasheet includes CE, BV, RINA and DNV, which are relevant to marine and offshore enclosures; the quality labels listed for this reference are KEMA and IMQ. Check that any project-specific approval you need is on that list before you order.
Mounting, wiring and add-on blocks for the A9P52616
The breaker clips onto a DIN rail and occupies 2 modules. Tunnel terminals at top and bottom accept 1–10 mm² flexible or 1–16 mm² rigid conductors; strip 14 mm and tighten to 2 N.m. The neutral is on the left, so keep the wiring order consistent across the board when several single-phase circuits sit next to each other. A padlocking device holds the toggle in the open position, and an earth-leakage block can be added as a separate module on the supply side where the project requires residual-current protection. Trip indicator and ON/OFF indication make it easy to see from the front which circuit tripped.
Documents and quotation
The manufacturer’s product datasheet for the A9P52616 is attached on this page for reference; it is the document to use when you verify ratings, dimensions and approvals against your own design. It lists the rated values for this exact reference.
To receive a quotation, send the part number A9P52616 with quantity and delivery location in Oman or the GCC. Seven Star LLC replies with availability and lead time as an independent supplier based in Muscat.
Datasheets & Documents
- Datasheet Schneider Electric A9P52616 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Schneider Electric is the French group for energy management and industrial automation: low and medium voltage switchgear and circuit breakers, motor control, drives, PLCs, power monitoring, UPS systems and building management. Its history goes back to 1836, when the brothers Adolphe and Eugène Schneider took over the iron and steel works at Le Creusot in Burgundy. Over the 20th century the company left steel and heavy engineering and became an electrical group through acquisitions such as Merlin Gerin, Télémécanique, Square D and Modicon. Its head office is in Rueil-Malmaison near Paris, and its shares are listed on Euronext Paris.
Schneider Electric company profile
| Origins | 1836, Le Creusot, France: Adolphe and Eugène Schneider take over the Le Creusot foundry |
|---|---|
| Headquarters | Rueil-Malmaison (Paris region), France |
| Ownership | Public company listed on Euronext Paris |
| Key acquisitions | Télémécanique (1988), Square D (1991), Merlin Gerin (1992), Modicon (1997), APC (2007), Invensys (2014); majority owner of AVEVA software |
| Brand names still in use | Acti9, ComPacT and MasterPacT breakers, TeSys motor control, Altivar drives, Altistart soft starters, Modicon PLCs, Harmony control components, PowerLogic and Easergy protection and metering, APC UPS, EcoStruxure software platform |
| Product families | Low voltage distribution, medium voltage switchgear and protection relays, motor control and drives, PLCs and HMIs, power meters, UPS and cooling, enclosures, building automation and energy software |
Milestones
- 1836: The Schneider brothers acquire the Le Creusot works; the business grows in steel, locomotives and heavy engineering.
- 1975: First investment in Merlin Gerin, a French maker of electrical distribution equipment.
- 1988–1992: Télémécanique, Square D (USA) and Merlin Gerin join the group, making it an electrical specialist.
- 1997: Modicon, the company behind the first programmable logic controller, joins the group.
- 1999: The group takes the name Schneider Electric.
- 2007 and 2014: APC (UPS and data centre power) and Invensys (process automation) are acquired.
Choosing Schneider Electric breakers and motor control
Circuit breakers are chosen by current and breaking capacity. Acti9 miniature circuit breakers (iC60, C120) protect final circuits up to 125 A. ComPacT NSX molded case breakers cover about 16 to 630 A, and the letter after the frame size sets the breaking capacity: B, F, N, H, S, L from lowest to highest. MasterPacT air circuit breakers are used as main incomers on large switchboards. For motors, a TeSys contactor with an LRD overload relay or a GV2 motor circuit breaker suits direct starting, an Altistart soft starter reduces starting current, and an Altivar drive controls speed. The breaking capacity must always be at least the prospective short-circuit current at the point of installation.
Where Schneider Electric products are used
In Oman and the GCC, Schneider Electric equipment is found in main and sub-main switchboards of commercial and residential buildings, motor control centres in water, oil and gas and industrial plants, substations protected by Sepam and Easergy relays, data centres powered by Galaxy and APC UPS systems, and buildings controlled by EcoStruxure Building Operation.
APC by Schneider Electric: UPS and critical power
Since 2007, APC has been part of Schneider Electric and is now its product brand for uninterruptible power supplies, replacement batteries, battery packs, network management cards and rack power distribution. Our APC catalogue covers Smart-UPS line-interactive and on-line models, Easy UPS On-Line, the modular Symmetra LX, RM and PX ranges, Silcon three-phase systems and their spare part kits, and the RBC cartridges that keep them running. Schneider Electric breakers, drives and PLCs can be quoted together with APC UPS systems in one request.
Schneider Electric products we list
| Family | Examples |
|---|---|
| Circuit breakers | Acti9 iC60N, C120N, NSX100F, NSX250N, NSX630, EasyPact EZC, MasterPacT MTZ1, MasterPacT NW |
| Motor control | TeSys Deca LC1D, TeSys F, LRD overload relay, GV2ME08, Altistart 22, Altistart 480 |
| Drives | Altivar 12, Altivar 320, ATV340, Altivar Process 630, ATV930, Lexium 32 servo |
| PLCs, HMIs and relays | Modicon M221, M241, M580 BMEP582040, Zelio Logic, Magelis HMISTU655 |
| Protection, metering and power | Sepam series 20, Easergy P3U30, MiCOM P139, PM5560, iEM3255, Galaxy VS UPS |
Ordering Schneider Electric products: what we need
Send the commercial reference from the label (for example LC1D18M7 or ATV320U22N4C). For breakers, confirm the rated current, number of poles, breaking capacity and trip unit. For contactors, give the coil voltage. For drives, give the motor power and supply voltage. APC products are listed on their own brand page.
Facts checked against Schneider Electric's published company history, October 2026.
Browse Schneider Electric products by category: Circuit Breaker, Electrical & Power Modules, AC Drives, PLC & I/O Cards, Metering Systems, UPS and Batteries.
FAQ
Questions about the Schneider Electric A9P52616 Acti9 iC40 1P + N 16 A
Answers from our engineering team on installation, compatibility and integration.
01What is the A9P52616?
It is a Schneider Electric Acti9 iC40 miniature circuit-breaker, 1P + N, 16 A, C curve, thermal-magnetic, 18 mm wide on a DIN rail.
02What breaking capacity does the A9P52616 have?
The datasheet lists 6 kA Icu to EN/IEC 60947-2 and 4.5 kA Icn to EN/IEC 60898-1 at 230 V AC.
03Which approvals are listed for the A9P52616?
The datasheet lists CE, BV, RINA and DNV certifications, with quality labels as shown in the specification table on this page.
04Can an earth-leakage block be added to the A9P52616?
Yes, the datasheet lists earth-leakage protection as a separate block. Confirm the exact block reference with the manufacturer's range data.
05What conductor sizes fit the A9P52616?
Top and bottom tunnel terminals accept 1-10 mm2 flexible or 1-16 mm2 rigid conductors with 14 mm stripping and 2 N.m torque.