- Automation & ControlView all 1,652 products
- AC Drives
- Industrial Communications
- PLC & I/O Cards
- Vibration Monitoring
- Automation Accessories
- Controllers & Data Acquisition
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- Industrial Computers
- Servo Drives
- Isolator & Barrier
- Motor Soft Starters
- HMI Displays
- Pneumatic Cylinders
- Automation Software
- Machine Vision
- Robotics
Brand: Phoenix Contact
Phoenix Contact QUINT4-PS/1AC/24DC/40 Power Supply 24 V 40 A
Description
QUINT4-PS/1AC/24DC/40 power supply, 24 V DC 40 A (960 W)
The QUINT4-PS/1AC/24DC/40 (item number 2904603) is the largest single-phase unit of the QUINT4 POWER line: 24 V DC at 40 A, or 960 W, from a wide-range 100 to 240 V AC input. It carries the same SFB technology and preventive monitoring as its smaller siblings but with the extra headroom needed for large control panels, I/O-intensive racks and groups of valve actuators. Seven Star LLC supplies the QUINT4-PS/1AC/24DC/40 in Oman and the GCC as an independent supplier in Muscat, and this page summarises the data sheet to help with sizing and RFQ preparation.
QUINT4-PS/1AC/24DC/40 type code and power ladder
The code reads QUINT4-PS (fourth-generation QUINT POWER), 1AC (single-phase input), 24DC (24 V DC output) and 40 (40 A). On the single-phase ladder the 40 A unit follows the 20 A type, which delivers 480 W, and doubles it. It is physically wider: 120 x 130 x 140 mm and 2.6 kg, against 70 mm width and 1.3 kg for the 20 A type, so cabinet space should be planned in advance.
QUINT4-PS/1AC/24DC/40 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Phoenix Contact QUINT4-PS/1AC/24DC/40, item no. 2904603 |
| Input voltage range | 100 V AC … 240 V AC (-15 % … +10 %); also DC feeding per data sheet |
| Frequency | 50 Hz … 60 Hz; 16.7 Hz railway networks per EN 50163 |
| Current draw | typ. 11.6 A at 100 V AC, 10 A at 120 V AC, 5.2 A at 230 V AC, 5.1 A at 240 V AC |
| Mains buffering | typ. 29 ms (120 V AC), typ. 32 ms (230 V AC) |
| Input fuse | 16 A slow-blow, internal |
| Output voltage | 24 V DC nominal, adjustable 24 … 29.5 V DC |
| Output current | 40 A nominal; 45 A static boost; 60 A dynamic boost for 5 s; 215 A SFB for 15 ms |
| Output power | 960 W nominal; dynamic boost 1,440 W |
| Efficiency | typ. 94.8 % (120 V AC), typ. 95.9 % (230 V AC) |
| Residual ripple | < 50 mVPP |
| Signaling | Configurable Out 1, Out 2 and relay contact 13/14 (24 V DC 1 A, 30 V AC/DC 0.5 A) |
| Ambient temperature | -25 °C … +70 °C, derating 2.5 %/K above 60 °C |
| MTBF (IEC 61709, SN 29500) | > 555,000 h at 40 °C |
| Dimensions / weight | 120 x 130 x 140 mm (W x H x D); 2.6 kg |
| Approvals listed | UL 508 and ANSI/ISA-12.12.01 Class I Div 2 Groups A-D; DNV GL shipbuilding |
Power reserves of the 40 A unit
The QUINT4-PS/1AC/24DC/40 supplies 45 A as a static boost, which is 125 % of nominal, and 60 A for five seconds as a dynamic boost, which equals 200 %. The SFB pulse is 215 A for 15 ms. In practice this means that a 40 A bus can protect many 6 A or 10 A branch breakers selectively: a short on one branch forces the unit to deliver enough current for the breaker to trip magnetically, while the remaining branches stay at voltage. The data sheet quotes control deviation of under 0.5 % for static load change and under 1 % for dynamic load change from 10 to 90 %, so the voltage stays stable during switching of large groups of loads.
Efficiency, losses and cabinet heat
A QUINT4-PS/1AC/24DC/40 at nominal load dissipates at most 50 W, according to the data sheet, at both 120 V AC and 230 V AC. With efficiency of 94.8 to 95.9 % this is among the lower-loss options in this power class, which helps in cabinets without active cooling. Even so, the unit should be mounted with free air space above and below, and the ambient temperature around it should be checked against the 60 °C derating threshold, above which output current falls by 2.5 % per kelvin.
System fit and related types
The QUINT4-PS/1AC/24DC/40 is the main supply for large PLC cabinets and instrument marshalling panels. Smaller loads suit the QUINT4-PS/1AC/24DC/10 or QUINT4-PS/1AC/24DC/20, and a three-phase source is better served by the QUINT4-PS/3AC/24DC/40/CO. Parallel operation for redundancy or capacity increase is permitted by the data sheet, and the output terminals take conductors up to 16 mm² flexible, which suits the high current. Downstream, multi-channel electronic circuit breakers and surge protection plugs from the accessory list are commonly paired with the unit.
Selection checklist
- Calculate the real 24 V load and verify that the 40 A rating, plus margin, covers it.
- Check that the AC upstream breaker is sized for the 16 A internal fuse and the input current at the lowest mains voltage (11.6 A at 100 V AC).
- Allocate 120 mm of DIN rail width and 140 mm depth.
- Plan output wiring up to 16 mm² and the cable length to hold voltage drop within limits.
- Check the approvals required by the project (marine, hazardous location).
Installation and maintenance
For the QUINT4-PS/1AC/24DC/40, follow the data sheet torque values, set the output voltage after the load is connected, and configure the signal outputs to suit the PLC. A periodic review should confirm the LED bar graph does not show persistent boost operation, which would indicate an undersized supply, and should keep the ventilation slots clear of dust. Keep a spare unit or at least plan lead time for critical plants.
Typical applications in Oman and the GCC
The QUINT4-PS/1AC/24DC/40 class suits gas compression and metering skids, pumping stations, desalination RO control cabinets, power-plant auxiliary panels and large I/O cabinets in petrochemical units. Hot cabinets in coastal and desert sites make the efficiency figure and the 70 °C operating limit relevant, while a wide AC input allows the same type to be used at 230 V sites and at some 110 V sources.
Information to send with an RFQ
- Full type designation or item number, and quantity
- Mains voltage and frequency at site, and whether the supply is AC, DC or three-phase
- Total load current including inrush and motor starting, plus any redundancy or parallel-operation requirement
- Ambient temperature range, altitude and cabinet ventilation
- Required approvals such as marine, hazardous-area or UL, and any project specification references
- Delivery location and required documents
Documents and quotation
The manufacturer data sheet for the QUINT4-PS/1AC/24DC/40 is attached to this page.
Send item number 2904603, quantity and delivery location to Seven Star LLC and request a quotation.
Other Models in the Pc Quint4 Ps Range
Seven Star LLC supplies models from the Pc Quint4 Ps range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Phoenix Contact QUINT4-PS/1AC/24DC/20 Power Supply 24 V 20 A | Power Modules | View details |
| Phoenix Contact QUINT4-PS/3AC/24DC/20 3-Phase Power Supply | Power Modules | View details |
| Phoenix Contact QUINT4-PS/1AC/24DC/40 Power Supply 24 V 40 A | Power Modules | You are viewing this model |
| Phoenix Contact QUINT4-PS/1AC/24DC/5 Power Supply 24 V 5 A | Power Modules | View details |
Datasheets & Documents
- Datasheet Phoenix Contact QUINT4-PS/1AC/24DC/40 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Phoenix Contact is a German, family-owned manufacturer of electrical connection technology and industrial automation, founded in 1923 in Essen by Hugo Knümann. It began as a sales company, and in 1928 Knümann developed the modular terminal block mounted on a rail, the product the company is still best known for. Phoenix Contact is headquartered in Blomberg, North Rhine-Westphalia.
Seven Star LLC lists Phoenix Contact surge protection, power supplies and safety relays, and sources these components by order number for panel builders and maintenance teams in Oman.
Phoenix Contact company profile
| Founded | 1923, Essen, Germany, by Hugo Knümann, as Phönix Elektro- und Industrie-Bedarfsgesellschaft |
|---|---|
| Headquarters | Blomberg, Germany |
| Ownership | Family-owned (Eisert and Stührenberg families) |
| Key invention | The modular terminal block on a DIN rail, 1928 |
| Product families | CLIPLINE terminal blocks, PCB terminals and connectors, QUINT and TRIO power supplies, relay modules, surge protection, signal conditioners, Ethernet switches and PLCnext controllers |
Milestones
- 1923: Hugo Knümann founds the company in Essen.
- 1928: The first modular terminal block is developed.
- Later: Headquarters move to Blomberg, Ostwestfalen-Lippe.
Phoenix Contact parts listed on this page
The TTC-6-2X1-24DC-UT (order number 2906799) is a surge protection device with screw connection for two 24 V DC signal wires that share a common reference potential. The QUINT-PS/1AC/24DC/10 is a single-phase DIN rail power supply delivering 24 V DC at 10 A. The PSR-SCP-24DC/ESP4/2X1/1X2 (order number 2981020) is a single-channel PSR safety relay for emergency stop and safety door monitoring, with two enabling current paths and plug-in screw terminals.
Phoenix Contact products we list
Ordering Phoenix Contact components: what we need
Phoenix Contact items are ordered by a seven-digit order number together with the type designation, both printed on the side of the module. Send both, plus the quantity. If the number is unreadable, send the type text and a photo. For power supplies, state input voltage, output current and whether the unit runs in parallel or with a redundancy module. For buyers in the GCC replacing an older unit, we check the manufacturer's documentation for the listed successor type.
Facts checked against Phoenix Contact's own company history (phoenixcontact.com), October 2026.
Browse Phoenix Contact products by category: Isolator & Barrier, Power Modules, Automation Accessories.
FAQ
Questions about the Phoenix Contact QUINT4-PS/1AC/24DC/40 Power Supply
Answers from our engineering team on installation, compatibility and integration.
01What output does the QUINT4-PS/1AC/24DC/40 provide?
24 V DC nominal at 40 A (960 W), with 45 A static boost, 60 A dynamic boost for 5 seconds and a 215 A SFB pulse for 15 ms.
02What is the physical size and weight?
The data sheet gives 120 x 130 x 140 mm (width x height x depth) and 2.6 kg.
03How efficient is it?
Typical efficiency is 94.8 percent at 120 V AC and 95.9 percent at 230 V AC with nominal values.
04What are the input current figures?
Typical current draw is 11.6 A at 100 V AC, 10 A at 120 V AC, 5.2 A at 230 V AC and 5.1 A at 240 V AC under static boost conditions.
05Is parallel operation possible?
Yes. The data sheet allows parallel connection for redundancy and increased capacity, and series connection is also stated as possible.


















Reviews
There are no reviews yet.