Phoenix Contact PLT-SEC-T3-230-FM-UT Type 2/3 Surge Protector

Description

PLT-SEC-T3-230-FM-UT: Type 2/3 surge protector for 230 V mains, screw terminals

The Phoenix Contact PLT-SEC-T3-230-FM-UT (order no. 2907919) is the 230 V member of the series, classed Type 2/3 and listed for TT systems. It has screw terminals, a status indicator and a remote indication contact. Nominal voltage is 240 V AC with 264 V AC maximum continuous operating voltage and 275 V AC for the other rating.

Seven Star LLC supplies the PLT-SEC-T3-230-FM-UT as an independent supplier in Muscat for projects in Oman and the GCC, quoted against the exact part number shown here.

Technical specifications of the PLT-SEC-T3-230-FM-UT

Parameter Specification
Manufacturer / part number Phoenix Contact PLT-SEC-T3-230-FM-UT (order no. 2907919)
Product family SEC Family
Mains system TT; TN-S
IEC test class II / III; T2 / T3
EN type T2 / T3
Mode of protection L-N; L-PE; N-PE
Nominal voltage UN 240 V AC (TN-S); 240 V AC (TT)
Max. continuous operating voltage UC 264 V AC
Rated load current IL 26 A (at 30 °C)
Nominal discharge current In (8/20 us) 5 kA
Max. discharge current Imax (8/20 us) 10 kA
Combination wave UOC 6 kV
Protection level Up L-N ≤ 1.25 kV (at UOC); ≤ 1.4 kV (at In)
Protection level Up L-PE ≤ 1.4 kV
Response time L-N ≤ 25 ns
Short-circuit current rating ISCCR 10 kA AC
Maximum backup fuse, through wiring 25 A (gG / B / C)
Remote indication contact Changeover contact
Connection method Screw connection
Conductor cross-section, flexible 0.2 mm² – 2.5 mm²
Ambient temperature (operation) -40 °C – 80 °C
Degree of protection IP20
Mounting DIN rail: 35 mm
Dimensions (W x H x D) 17.7 x 93.4 x 74.5 (incl. DIN rail 7.5) mm

How the PLT-SEC-T3-230-FM-UT works

The PLT-SEC-T3-230-FM-UT belongs to the PLT-SEC series, in which a surge protective plug is inserted into a base element that holds the terminals and the remote-indication contact. When a voltage spike on the line exceeds the protection level, the protective components in the plug conduct and limit the voltage across the connected equipment; the datasheet gives the voltage protection level Up and the residual voltages for different discharge currents. Pulling the plug out removes the protection without disturbing the wiring, which is useful for replacement or insulation tests. A status indicator on the plug and a changeover contact in the base signal when the protection has been used up.

The nominal discharge current is 5 kA and the maximum 10 kA (8/20 us), with a protection level of up to 1.25 kV L-N and 1.4 kV L-PE. Response time is 25 ns L-N and 100 ns to PE.

Where the PLT-SEC-T3-230-FM-UT fits in a system

Surge protectors of Type 3 (and the combined Type 2/3 variants) are installed near the equipment they protect, after the Type 1 and Type 2 stages at the building entrance and the distribution board. They limit the residual voltage that reaches electronics such as power supplies, PLC modules and communication devices. The series comes with different plugs for 24, 120 and 230 V, and with screw (UT) or push-in (PT) terminals, so the correct plug must be matched to the line voltage.

The PLT-SEC-T3-230-FM-UT is the one to choose for 230 V single-phase supplies feeding electronics. For 120 V, 2907918 is the correct plug; for a base element alone, 2907929.

Selection and ordering checklist

  • Match the nominal voltage of the plug to the line: the PLT-SEC-T3-230-FM-UT is rated as shown in the table.
  • Check the mains system (TN-S or TT) listed for the device.
  • Confirm the load current is within the rated load current IL.
  • Confirm the backup fuse size for through wiring against the limit in the table.
  • Choose screw (UT) or push-in (PT) terminals to suit the wiring standard in your panel.
  • Plan whether the remote-indication contact will be connected to a controller.

Installation, commissioning and maintenance of the PLT-SEC-T3-230-FM-UT

Clip the PLT-SEC-T3-230-FM-UT on a 35 mm DIN rail and connect line and neutral through the terminals (through wiring) or in branch wiring as the datasheet shows. Ground the PE terminal with a short, low-impedance conductor, because lead length adds to the let-through voltage during a surge. Keep the wiring from the protective device to the protected equipment short, and check the status indicator at each service visit.

Back-up fuse is up to 25 A for through wiring and up to 32 A for branch wiring.

Typical applications in Oman and the GCC

In Oman and the GCC, thunderstorms are less frequent than in many regions but switching transients, long overhead lines and generator sets all create surges. Protectors are common in telecom shelters, solar plants, oil and gas instrument cabinets and power-plant auxiliaries.

GCC mains at 230 V single-phase appears in building services, telecom and small process panels.

Comparison with related PLT-SEC surge protection devices

Device Distinguishing data
PLT-SEC-T3-24-FM-UT (2907916) Type 3, 24 V AC/DC plug, screw terminals
PLT-SEC-T3-24-FM-PT (2907925) Type 3, 24 V AC/DC plug, push-in terminals
PLT-SEC-T3-120-FM-UT (2907918) Type 2/3, 120 V, screw terminals
PLT-SEC-T3-230-FM-UT (2907919) Type 2/3, 230 V, screw terminals
PLT-SEC-T3-230-FM-PT (2907928) Type 2/3, 230 V, push-in terminals
PLT-SEC-T3-BE-FM-PT (2907929) Base element only, push-in terminals
PLT-SEC-T3-230-FM (2905229) Type 3 device on our site as a separate page

Information to send with an RFQ

  • Full part number PLT-SEC-T3-230-FM-UT and quantity.
  • Line voltage, mains system and whether AC or DC.
  • Load current and backup fuse size.
  • Terminal type (screw or push-in).
  • Whether remote indication is needed.
  • Delivery location and date.

Documents and quotation

Send us the part number PLT-SEC-T3-230-FM-UT and the quantity you need, and we will confirm which official documents are available for this device. Seven Star LLC is an independent supplier in Muscat and quotes for projects across Oman and the GCC; we do not act on behalf of the manufacturer.

Please also tell us the delivery location and required timeline so that availability can be checked before you commit to a project schedule.

Other Models in the Phoenix Plt Sec T3 Range

Seven Star LLC supplies models from the Phoenix Plt Sec T3 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Phoenix Contact PLT-SEC-T3-24-FM-UT Type 3 Surge ProtectorIsolator & BarrierView details
Phoenix Contact PLT-SEC-T3-24-FM-PT Type 3 Surge ProtectorIsolator & BarrierView details
Phoenix Contact PLT-SEC-T3-120-FM-UT Type 2/3 Surge ProtectorIsolator & BarrierView details
Phoenix Contact PLT-SEC-T3-230-FM-UT Type 2/3 Surge ProtectorIsolator & BarrierYou are viewing this model
Phoenix Contact PLT-SEC-T3-BE-FM-PT Surge Protection BaseIsolator & BarrierView details
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Phoenix Contact is a German, family-owned manufacturer of electrical connection technology and industrial automation, founded in 1923 in Essen by Hugo Knümann. It began as a sales company, and in 1928 Knümann developed the modular terminal block mounted on a rail, the product the company is still best known for. Phoenix Contact is headquartered in Blomberg, North Rhine-Westphalia.

Seven Star LLC lists Phoenix Contact surge protection, power supplies and safety relays, and sources these components by order number for panel builders and maintenance teams in Oman.

Phoenix Contact company profile

Founded 1923, Essen, Germany, by Hugo Knümann, as Phönix Elektro- und Industrie-Bedarfsgesellschaft
Headquarters Blomberg, Germany
Ownership Family-owned (Eisert and Stührenberg families)
Key invention The modular terminal block on a DIN rail, 1928
Product families CLIPLINE terminal blocks, PCB terminals and connectors, QUINT and TRIO power supplies, relay modules, surge protection, signal conditioners, Ethernet switches and PLCnext controllers

Milestones

  • 1923: Hugo Knümann founds the company in Essen.
  • 1928: The first modular terminal block is developed.
  • Later: Headquarters move to Blomberg, Ostwestfalen-Lippe.

Phoenix Contact parts listed on this page

The TTC-6-2X1-24DC-UT (order number 2906799) is a surge protection device with screw connection for two 24 V DC signal wires that share a common reference potential. The QUINT-PS/1AC/24DC/10 is a single-phase DIN rail power supply delivering 24 V DC at 10 A. The PSR-SCP-24DC/ESP4/2X1/1X2 (order number 2981020) is a single-channel PSR safety relay for emergency stop and safety door monitoring, with two enabling current paths and plug-in screw terminals.

Phoenix Contact products we list

Family Examples
Isolator & Barrier 2906799 TTC-6-2X1-24DC-UT Surge Protector, MACX MCR-EX-SL-RPSSI-I Signal Isolator, MINI MCR-2-UI-UI 3-Way Signal Conditione…, PLT-SEC-T3-230-FM Type 3 Surge Protectio…
Power Modules QUINT-PS/1AC/24DC/10 QUINT Power Supply, QUINT4-PS/1AC/24DC/10 Power Supply, TRIO-PS-2G/1AC/24DC/10 Power Supply, UNO-PS/1AC/24DC/100W Power Supply
Automation Accessories PLC-RSC-24DC/21 Relay Module, PSR-SCP-24DC/ESP4/2X1/1X2 Safety Relay (…

Ordering Phoenix Contact components: what we need

Phoenix Contact items are ordered by a seven-digit order number together with the type designation, both printed on the side of the module. Send both, plus the quantity. If the number is unreadable, send the type text and a photo. For power supplies, state input voltage, output current and whether the unit runs in parallel or with a redundancy module. For buyers in the GCC replacing an older unit, we check the manufacturer's documentation for the listed successor type.

Facts checked against Phoenix Contact's own company history (phoenixcontact.com), October 2026.

FAQ

Questions about the Phoenix Contact PLT-SEC-T3-230-FM-UT Type 2/3 Surge

Answers from our engineering team on installation, compatibility and integration.

01What is the nominal voltage?
240 V AC, listed for 230 V single-phase supply.
02What is the L-N protection level?
Up to 1.25 kV.
03What discharge currents?
5 kA nominal and 10 kA maximum at 8/20 us.
04What mains system is listed?
TT.
05What is the backup fuse limit?
25 A through wiring, 32 A with branch wiring.