Brand: Pepperl+Fuchs
Pepperl+Fuchs NJ2-12GM-N NAMUR Inductive Sensor M12, 2 mm
Description
Pepperl+Fuchs NJ2-12GM-N overview
The Pepperl+Fuchs NJ2-12GM-N is an M12 cylindrical inductive proximity sensor with a NAMUR output from Pepperl+Fuchs. It has a rated operating distance of 2 mm for flush installation, a normally closed switching function and a two-wire output designed to work with NAMUR switch amplifiers. The datasheet, released on 14 December 2020, states that the sensor can be used up to SIL 2 according to IEC 61508, which makes the NJ2-12GM-N a common choice for position and presence detection in safety-related loops.
The sensor housing is stainless steel (1.4305 / AISI 303) with a PBT sensing face, and the NJ2-12GM-N is supplied with a fixed 2 m PVC cable and two self-locking nuts. The degree of protection is IP66/IP67 and the ambient temperature range is -25 to 100 degrees C. Approvals listed in the datasheet include ATEX, IECEx, FM, UL, CSA, CCC and NEPSI, and a marine approval from DNV GL. The NJ2-12GM-N is also marked for use in hazardous areas, up to equipment protection level Ga when connected to a suitable isolator.
Key features of the Pepperl+Fuchs NJ2-12GM-N
- M12 x 1 thread, 35 mm overall length, flush installation with 2 mm rated operating distance
- NAMUR two-wire output, normally closed, compatible with 2:1 technology without a reverse polarity protection diode
- Assured operating distance 0 to 1.62 mm, hysteresis 3 percent, switching frequency 0 to 2000 Hz
- Usable up to SIL 2 per IEC 61508; MTTFd 5887 years, mission time 20 years, diagnostic coverage 0 percent
- Stainless steel housing, PBT sensing face, IP66/IP67 protection
- Fixed PVC cable of 2 m with 0.34 square mm cores; two self-locking nuts included
- Temperature range -25 to 100 degrees C
- Accessories available: BF 12 mounting flange and EXG-12 quick-mounting bracket with dead stop
NJ2-12GM-N technical specifications
Specifications are taken from the NJ2-12GM-N datasheet released 2020-12-14.
| Parameter | Value |
|---|---|
| Model | NJ2-12GM-N inductive sensor |
| Switching function | Normally closed (NC) |
| Output type | NAMUR, 2-wire |
| Rated operating distance sn | 2 mm |
| Installation | Flush |
| Assured operating distance sa | 0 to 1.62 mm |
| Reduction factors | rAl 0.4; rCu 0.3; r304 0.85 |
| Nominal voltage Uo | 8.2 V (Ri approx. 1 kohm) |
| Operating voltage UB | 5 to 25 V |
| Switching frequency f | 0 to 2000 Hz |
| Hysteresis H | 3 percent |
| Current consumption | Measuring plate not detected: 3 mA or more at nominal voltage; detected: 1 mA or less |
| Functional safety | SIL 2; MTTFd 5887 a; mission time 20 a; DC 0 percent |
| NAMUR conformity | EN 60947-5-6:2000, IEC 60947-5-6:1999 |
| Standards | EN 60947-5-2:2007, IEC 60947-5-2:2007 with amendment |
| ATEX | PTB 00 ATEX 2048 X (Ga, Gb, Da) |
| IECEx | IECEx PTB 11.0037X (Ga, Gb, Da, Mb) |
| Other approvals | FM control drawing 116-0165, cULus, CSA, CCC, NEPSI GYJ16.1393X, DNV GL TAA00001A5, EAC TR CU 012/2011 |
| Ambient temperature | -25 to 100 degrees C |
| Housing material | Stainless steel 1.4305 / AISI 303; sensing face PBT |
| Degree of protection | IP66 / IP67 |
| Connection | Fixed PVC cable, 4.8 mm diameter, 0.34 square mm, length 2 m |
| Dimensions | M12 x 1 thread, length 35 mm |
| Scope of delivery | Two self-locking nuts |
Because the NJ2-12GM-N uses a normally closed NAMUR output, a metal target in the sensing range reduces the current to 1 mA or less and a clear sensing face gives 3 mA or more. This lets the switch amplifier distinguish a normal state from wire break (current near zero) and short circuit, which is the main reason NAMUR sensors are chosen for safety loops.
Typical applications in oil and gas, utilities, water and manufacturing
NAMUR inductive sensors such as the NJ2-12GM-N are standard for position feedback in hazardous areas. In oil and gas facilities in Oman, they are fitted on valve actuators and limit-switch boxes to indicate open and closed positions, on rotating machinery for speed or zero-speed detection, and on loading arms and skid mechanisms. Stainless steel housings and IP67 protection suit the heat, dust and salt air of coastal sites such as Sohar, Duqm and Salalah.
In water, power and process plants across the GCC, the NJ2-12GM-N detects the position of gates, dampers and dosing mechanisms, and counts or confirms presence in packaging and manufacturing lines. The SIL 2 suitability supports its use in shutdown and interlock loops when combined with a suitable isolating switch amplifier.
Selection and compatibility notes for NJ2-12GM-N
Use the NJ2-12GM-N with an intrinsically safe NAMUR switch amplifier or isolating barrier approved for the zone and gas group. Check the amplifier and cable against the entity parameters in the sensor certificate. For flush mounting, keep the surrounding metal clear in line with the datasheet; the 2 mm rated distance applies to a standard steel target, and the reduction factors in the table apply to other metals, such as 0.4 for aluminium and 0.3 for copper.
If you need a different distance or housing, other sensors in the NJ series of the manufacturer, for example non-flush versions, are available. If the cable length or connector type is critical, check the exact variant: the NJ2-12GM-N has a fixed 2 m cable, and plug versions carry different type codes.
Installation and commissioning
Mount the NJ2-12GM-N in a bracket or drilled hole with the two supplied self-locking nuts. Keep the nuts tight but avoid over-torquing the M12 x 1 thread. Observe the free zone around the sensing face and make sure the target passes within the assured operating distance of 1.62 mm, allowing for vibration and wear of mechanical parts. The BF 12 flange and EXG-12 bracket offer repeatable positioning and a dead stop to protect the sensing face.
Connect the brown conductor to L+ and the blue to L- of the NAMUR amplifier, protect the cable from mechanical damage and route it away from power cables. Commission the loop by moving a target in and out of range and verifying the amplifier output state, wire-break and short-circuit alarms. Record the result in the loop file for the NJ2-12GM-N.
Maintenance and service life
Inductive sensors have no moving parts and need little maintenance. During inspections, check that the NJ2-12GM-N is not loosened by vibration, that the sensing face is free from heavy deposits and mechanical damage, and that the cable sheath is intact. Verify the switching distance against the original setting at planned shutdowns.
For safety-related use, follow the proof-test interval defined in your safety plan, using the functional safety data from the datasheet such as MTTFd and mission time. Replace the sensor if the housing or cable is damaged or if the switching distance has drifted.
Related products and ordering notes
Customers who enquire about the NJ2-12GM-N often also need matching accessories and neighbouring models from the same family, such as NAMUR switch amplifiers and isolated barriers, the BF 12 mounting flange, the EXG-12 quick-mounting bracket and other NJ-series sensors. Tell us the amplifier model you plan to use so we can help to check compatibility.
When you send an enquiry for the NJ2-12GM-N, please quote the full part number exactly as printed on the nameplate, the quantity, and the intended application. If you are replacing an installed unit, a photograph of the nameplate helps us confirm the NJ2-12GM-N you need. Our team can arrange a quotation with delivery to Oman and across the GCC.
Frequently asked questions about NJ2-12GM-N
The NJ2-12GM-N is an M12 flush NAMUR inductive sensor with a 2 mm rated distance, a normally closed output, SIL 2 suitability, stainless steel housing, IP66/IP67 protection and a 2 m cable. It operates on 5 to 25 V with a nominal 8.2 V and is used with NAMUR amplifiers.
Documents and quotation
A copy of the datasheet for the NJ2-12GM-N is available on this page for your engineering review. To request a quotation, send the RFQ with the part number NJ2-12GM-N, the quantity, the delivery location and any certification or documentation requirements, and we will respond with availability and lead time. Please review the specification against your loop or system requirements before ordering.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with Pepperl+Fuchs. Product names and part numbers are used only to identify the item you ask for.
Datasheets & Documents
- Datasheet NJ2-12GM-N Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs NJ2-12GM-N NAMUR Inductive Sensor
Answers from our engineering team on installation, compatibility and integration.
01What type of output does the NJ2-12GM-N have?
It has a two-wire NAMUR output with a normally closed switching function, designed for use with NAMUR switch amplifiers.
02What is the sensing distance of the NJ2-12GM-N?
The rated operating distance is 2 mm flush, and the assured operating distance is 0 to 1.62 mm.
03Is the NJ2-12GM-N suitable for safety loops?
The datasheet states usability up to SIL 2 according to IEC 61508, with MTTFd of 5887 years and a mission time of 20 years.
04What are the housing and protection of the NJ2-12GM-N?
The housing is stainless steel 1.4305 / AISI 303 with a PBT sensing face, with IP66/IP67 protection and an ambient range of -25 to 100 degrees C.
05How do I order the NJ2-12GM-N?
Send an RFQ quoting NJ2-12GM-N with quantity and delivery location in Oman or the GCC, and Seven Star LLC will reply with availability and lead time.


















Reviews