Pepperl+Fuchs KFD2-STV5-Ex1-1 Transmitter Supply 1-5 V
Description
KFD2-STV5-Ex1-1: SMART transmitter supply with a 1 to 5 V output
Where an I/O card expects a voltage instead of a current, the Pepperl+Fuchs KFD2-STV5-Ex1-1 supplies the field transmitter and converts its loop current into 1 to 5 V across an internal 250 ohm resistor. The card therefore sees a voltage signal with an output resistance of 250 ohm and ripple of no more than 12.5 mV.
The module keeps the STC5 housing (20 mm wide, type B2) and the test sockets for HART communicators, so technicians work with the same layout as with current-output barriers.
What it does
- Powers 2-wire and 3-wire SMART transmitters and works with 2-wire current sources
- Output 1 to 5 V on terminals 7-, 8+ and 9+
- Digital communication superimposed in the hazardous or safe area is transferred both ways
- If HART loop resistance is too low, the internal 250 ohm can serve as communication resistance
- SIL 2 (SC 3) capable according to IEC/EN 61508
KFD2-STV5-Ex1-1 data
| Parameter | Value |
|---|---|
| Supply | 18 to 30 V DC; 1 W dissipation; 1.6 W consumption at full load |
| Input signal | 4 to 20 mA, terminals 1+, 2-, 3 |
| Output signal | 1 to 5 V |
| Output resistance | 250 ohm |
| Output ripple | up to 12.5 mV |
| Settling time | 200 microseconds |
| Safe-side values | Uo 26.2 V, Uq 27.25 V, Io 93 mA, Po 634 mW |
| Certificate | CML 17 ATEX 2029X |
| Ambient | -20 to 70 degrees C |
| Dimensions, mass | 20 x 124 x 115 mm, about 150 g, IP20 |
Voltage versus current signals
Current signals are immune to cable resistance, whereas voltage signals lose accuracy if the receiver input impedance is low or the cable is long. The voltage output suits receivers with a high input impedance, such as some PLC analogue cards, indicators and recorders, and it lets a single measuring point be read by several high-impedance devices in parallel without breaking the loop. Keep cable lengths short and shielded.
Difference between KFD2-STV5-Ex1-1 and KFD2-STC5-Ex1
The STC5 types output 0/4 to 20 mA in sink or source mode into 0 to 800 ohm. KFD2-STV5-Ex1-1 has no current output and no external loop supply; instead the output is 1 to 5 V with 250 ohm source resistance. Both settle within 200 microseconds and share certificate CML 17 ATEX 2029X, a dimension of 124 mm height and a mass of 150 g.
Commissioning
Apply 4 mA and 20 mA from a transmitter simulator and read 1 V and 5 V at the output with a meter that has at least 10 megohm input impedance. A lower impedance meter will load the 250 ohm source and lower the reading.
Maintenance
Check linearity at three points during turnaround and record. Replace if the output drifts outside the tolerance defined by your instrument standards.
Ordering remarks
The suffix -1 identifies the voltage-output type; confirm with your receiver data sheet before purchase.
Integration with indicators and recorders
Panel indicators, chart recorders and data loggers often have 1 to 5 V inputs and are easy to add in parallel with the control card, because voltage inputs do not interrupt the loop. Keep the parallel load high, ideally above 1 megohm in total, so that the 250 ohm source impedance does not cause visible error: a 1 megohm load causes about 0.025 percent error from the divider effect. Shield the output cable and ground the shield at one end only. Live-zero 1 V at 4 mA also lets the receiver detect a broken wire as 0 V.
Safety notes
The certificate classification and entity values are the same as in the current-output STC5 version, which makes reuse of cable calculations straightforward. SIL 2 (SC 3) suitability under IEC/EN 61508 should be confirmed from the safety manual before the unit is used in a safety function; the manual lists failure rates and proof-test recommendations. Where the receiving card monitors input range, remember that a normal signal lies between 1 V and 5 V and that 0 V indicates a loop fault or a loss of supply.
Typical placement in a plant
Voltage-output transmitter supplies appear in packaged skids, burner management panels and older DCS upgrades where the input cards were designed around 1 to 5 V. A common example is a gas compressor package whose PLC reads 1 to 5 V from every analogue signal; the skid builder uses STV5 modules for the hazardous-area transmitters and keeps the PLC cards unchanged. Another example is a laboratory or pilot plant where several indicators are connected in parallel to one measurement. In every case, the 250 ohm output resistance and 12.5 mV ripple figures define how the signal behaves under load and noise, so the receiver designer should compare them with the input specification of the card.
Questions buyers ask about KFD2-STV5-Ex1-1
What output does KFD2-STV5-Ex1-1 provide? It gives 1 to 5 V with an output resistance of 250 ohm on terminals 7-, 8+ and 9+.
What is the ripple of KFD2-STV5-Ex1-1? The output ripple is a maximum of 12.5 mV.
Does KFD2-STV5-Ex1-1 support HART? Yes. HART, BRAIN and Foxboro signals are listed as supported, and the internal resistor can be used when the HART loop resistance is too low.
What input range does KFD2-STV5-Ex1-1 accept? It accepts 4 to 20 mA on terminals 1+, 2- and 3 from 2-wire or 3-wire SMART transmitters.
What ambient temperature range applies to KFD2-STV5-Ex1-1? The datasheet gives an ambient temperature range of -20 to 70 degrees C for this voltage-output model.
Documents and quotation
The manufacturer datasheet for KFD2-STV5-Ex1-1 accompanies this listing as a PDF so your engineers can verify terminals, ratings and approvals before purchase. Indicate the receiver input impedance when requesting a quotation. To request a quotation, send the RFQ with the exact part number KFD2-STV5-Ex1-1, the quantity, the delivery location in Oman or the GCC and any project reference. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Other Models in the Stc5 Stv5 Range
Seven Star LLC supplies models from the Stc5 Stv5 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFD2-STC5-Ex1.H High Voltage Supply | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-STC5-Ex1.2O Dual Output Supply | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-STC5-Ex1 SMART Transmitter Supply | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-STV5-Ex1-1 Transmitter Supply 1-5 V | Isolator & Barrier | You are viewing this model |
Datasheets & Documents
- Datasheet Pepperl+Fuchs KFD2-STV5-Ex1-1 Transmitter Supply 1-5 V Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-STV5-Ex1-1 Transmitter Supply
Answers from our engineering team on installation, compatibility and integration.
01What output does KFD2-STV5-Ex1-1 provide?
It gives 1 to 5 V with an output resistance of 250 ohm on terminals 7-, 8+ and 9+.
02What is the ripple of KFD2-STV5-Ex1-1?
The output ripple is a maximum of 12.5 mV.
03Does KFD2-STV5-Ex1-1 support HART?
Yes. HART, BRAIN and Foxboro signals are listed as supported, and the internal resistor can be used when the HART loop resistance is too low.
04What input range does KFD2-STV5-Ex1-1 accept?
It accepts 4 to 20 mA on terminals 1+, 2- and 3 from 2-wire or 3-wire SMART transmitters.
05What ambient temperature range applies to KFD2-STV5-Ex1-1?
The datasheet gives an ambient temperature range of -20 to 70 degrees C for this voltage-output model.