KFD2-STC5-Ex1: current-output SMART transmitter supply, fifth generation
The Pepperl+Fuchs KFD2-STC5-Ex1 is a one-channel, 20 mm wide barrier that powers two-wire and three-wire SMART transmitters in hazardous areas and delivers an isolated 0/4 to 20 mA signal to the control system. It succeeds the long-running STC4 types and adds a quick settling time of 200 microseconds, an ambient range up to 70 degrees C and test sockets for handheld communicators.
A key convenience is the mode choice on the safe side: terminals 7+, 8- and 9- give a sink output where the control card supplies the loop, while terminals 7-, 8+ and 9+ give a source output where the barrier supplies it. An internal resistor is available if the loop resistance is too low for HART communication.
Built-in advantages
- Input for 2-wire transmitters, 3-wire transmitters and 2-wire SMART current sources
- Bi-directional transfer of digital HART-type signals, bandwidth 0 to 7.5 kHz (field to control) and 0.3 to 7.5 kHz (control to field)
- Rise and fall time 100 microseconds, settling time 200 microseconds
- SIL 2 (SC 3) capability according to IEC/EN 61508
- Test points on the terminals for connecting a communicator without opening the loop
KFD2-STC5-Ex1 data
| Parameter | Value |
|---|---|
| Supply | 18 to 30 V DC, up to 1 W dissipation, up to 1.6 W consumption at maximum load |
| Input signal | 0/4 to 20 mA on terminals 1+, 2-, 3 |
| Open-circuit voltage / short-circuit current | 23 V / 25 mA |
| Available voltage at the transmitter | at least 16 V at 20 mA and 20 V at 4 mA |
| Input resistance | up to 265 ohm (terminals 2-, 3) or 330 ohm (1+, 3) |
| Output | 0/4 to 20 mA, load 0 to 800 ohm, overload above 25 mA |
| External loop supply | 2 to 30 V DC in sink mode |
| Ripple on output | up to 50 microamps rms |
| Deviation at 20 degrees C | up to 10 microamps incl. calibration, linearity and hysteresis |
| Temperature influence | up to 0.25 microamps per K |
| Safe-side values | Uo 26.2 V, Uq 27.25 V, Io 93 mA, Po 634 mW |
| ATEX certificate | CML 17 ATEX 2029X, [Ex ia Ga] IIC, [Ex ia Da] IIIC, [Ex ia Ma] I |
| Environment | -20 to 70 degrees C, IP20 |
| Dimensions and mass | 20 x 124 x 115 mm, housing B2, about 150 g |
Typical installations
Pressure and flow transmitters in refineries, LNG and gas-processing plants, differential-pressure instruments on filters in desalination plants and level transmitters on chemical storage tanks all connect through such a supply. The test sockets are particularly useful for technicians who calibrate transmitters on live loops, since they can clip a communicator on without lifting wires.
KFD2-STC5-Ex1 versus the other STC5 and STV5 variants
- KFD2-STC5-Ex1.2O has two outputs for splitting a signal, with a load limit of 0 to 600 ohm and SIL 3 listed; this single-output version allows 0 to 800 ohm.
- KFD2-STC5-Ex1.H raises the transmitter voltage: 17 V at 20 mA against 16 V here, but settles in 500 microseconds and tolerates only 60 degrees C ambient in the standard range.
- KFD2-STV5-Ex1-1 converts to 1 to 5 V with a 250 ohm output resistance instead of a current signal.
Wiring and commissioning
Supply the module on the Power Rail or terminals according to the connection diagram. Decide sink or source before wiring, because the two modes use different terminal polarity. In sink mode, a loop supply from 2 to 30 V is needed; if it exceeds the working range, add a series resistance as described in the manual. Verify HART communication with a handheld at the test sockets.
Maintenance
No routine calibration is demanded beyond loop checks at the maintenance interval defined by the plant. Inspect terminals and keep the module free from dust.
Alternative use as a current repeater
Because the input also accepts a 2-wire SMART current source, the same module can serve as a repeater for a hazardous-area current source such as a positioner feedback, providing isolation without the supply function.
Reading the entity data for loop approvals
Intrinsic safety documentation for this loop starts with the values on the hazardous side: Uo 26.2 V, Uq 27.25 V, Io 93 mA and Po 634 mW for the supply terminals, plus a separate low-power set of 2 V, 8.5 mA and 4.3 mW for the communication test points. The designer adds the transmitter parameters and cable capacitance and inductance, and confirms that the totals stay inside the group IIC limits stated on the certificate. For gas group IIB or IIA the permitted values are higher, which helps on long cables. Filing the certificate CML 17 ATEX 2029X with the loop diagram avoids repeated queries at site acceptance.
Questions buyers ask about KFD2-STC5-Ex1
What sink and source modes does KFD2-STC5-Ex1 offer? Sink mode uses terminals 7+, 8- and 9-, while source mode uses terminals 7-, 8+ and 9+, both delivering 0/4 to 20 mA.
What voltage reaches the transmitter on KFD2-STC5-Ex1? At least 16 V is available at 20 mA and 20 V at 4 mA on terminals 1+ and 3.
How fast is KFD2-STC5-Ex1? The settling time is 200 microseconds and the rise and fall time 100 microseconds.
What ambient temperature does KFD2-STC5-Ex1 allow? The datasheet gives -20 to 70 degrees C.
Does KFD2-STC5-Ex1 have test sockets? Yes, test sockets for connecting HART communicators are integrated into the terminals.
Documents and quotation
The manufacturer datasheet for KFD2-STC5-Ex1 accompanies this listing as a PDF so your engineers can verify terminals, ratings and approvals before purchase. Send the transmitter model so the voltage requirement can be checked. To request a quotation, send the RFQ with the exact part number KFD2-STC5-Ex1, the quantity, the delivery location in Oman or the GCC and any project reference. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Delivery to Sites in Oman and the GCC
Delivery of the Pepperl+Fuchs KFD2-STC5-Ex1 is arranged to suit the site, whether that is a plant in Sohar or Duqm, an oilfield location in the interior, or a project elsewhere in the GCC. Tell us the delivery point, any site access or gate-pass requirements, and the person who will receive the goods. Goods are packed to protect sensitive isolator & barrier equipment during road or air transport, and shipping details are shared once the order is dispatched so that your stores team can plan receipt and inspection.
Other Models in the Stc5 Stv5 Range
Seven Star LLC supplies models from the Stc5 Stv5 range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Pepperl+Fuchs KFD2-STC5-Ex1.H High Voltage Supply | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-STC5-Ex1.2O Dual Output Supply | Isolator & Barrier | View details |
| Pepperl+Fuchs KFD2-STC5-Ex1 SMART Transmitter Supply | Isolator & Barrier | You are viewing this model |
| Pepperl+Fuchs KFD2-STV5-Ex1-1 Transmitter Supply 1-5 V | Isolator & Barrier | View details |
Datasheets & Documents
- Datasheet Pepperl+Fuchs KFD2-STC5-Ex1 SMART Transmitter Supply Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Pepperl+Fuchs is a German manufacturer of industrial sensors and explosion protection equipment, founded in 1945 in Mannheim by Walter Pepperl and Ludwig Fuchs as a radio repair shop. Defective transformers led them into manufacturing, and the company developed its first proximity switch in the late 1950s. Pepperl+Fuchs is headquartered in Mannheim and is a pioneer of intrinsically safe electrical equipment for hazardous areas.
Seven Star LLC lists Pepperl+Fuchs sensors, isolated barriers, power supplies and hazardous-area mobile devices, and supplies them to instrument and automation teams in Oman by exact model designation.
Pepperl+Fuchs company profile
| Founded | 1945, Mannheim-Sandhofen, Germany, by Walter Pepperl and Ludwig Fuchs |
|---|---|
| Headquarters | Mannheim, Germany |
| Ownership | Privately owned (Pepperl+Fuchs SE) |
| Origins | Radio repair workshop that began making replacement transformers |
| Product families | Inductive, capacitive, ultrasonic and photoelectric sensors, rotary encoders, R2000 LiDAR scanners, KFD and HiC isolated barriers, Zener barriers, remote I/O, purge and pressurization systems, Ex-rated enclosures |
Milestones
- 1945: Walter Pepperl and Ludwig Fuchs open their radio repair shop in Mannheim.
- 1958: The first proximity switch is developed (some company sources say 1959).
Pepperl+Fuchs product families on this page
On the interface side there are two systems. The K-System mounts on DIN rail and is represented here by the KFD2-UT2-Ex2 universal temperature converter. The H-System plugs into termination boards and is represented by the HiD2030 SMART transmitter power supply with HART. The PS1000-A6-24.20 is a 24 VDC, 20 A power supply for cabinets. Sensors listed include the NJ2-12GK-SN NAMUR inductive sensor, the R101 retro-reflective photoelectric sensor and the R2000 2-D LiDAR scanner. For field staff there are the Tab-Ex 05 DZ1 tablet for Zone 1/21 areas and the Smart-Ex 03 DZ2 smartphone for Zone 2/22 and Division 2 areas.
Where Pepperl+Fuchs equipment is used
Isolated barriers sit between field instruments in Zone 0 or Zone 1 and the DCS or safety system in refineries, gas plants and chemical works. NAMUR sensors report valve position and machine states in classified areas. Photoelectric sensors and LiDAR scanners work in conveying, packaging, warehousing and vehicle guidance. Ex-rated tablets and phones are carried on operator rounds and maintenance jobs.
Pepperl+Fuchs products we list
Ordering Pepperl+Fuchs parts: what we need
Send the complete model designation as printed on the device, including every suffix; a single letter can change the supply voltage or the output type. Add the part number if the label shows one. For barriers, tell us the field device and signal type, the number of channels and whether the safety loop needs a SIL-assessed module. For mobile devices, state the zone or division and the regional radio version.
Facts checked against Pepperl+Fuchs's own chronicle pages, October 2026.
Browse Pepperl+Fuchs products by category: Sensors & Transmitters, Industrial Computer, Isolator & Barrier, Power Modules.
FAQ
Questions about the Pepperl+Fuchs KFD2-STC5-Ex1 SMART Transmitter Supply
Answers from our engineering team on installation, compatibility and integration.
01What sink and source modes does KFD2-STC5-Ex1 offer?
Sink mode uses terminals 7+, 8- and 9-, while source mode uses terminals 7-, 8+ and 9+, both delivering 0/4 to 20 mA.
02What voltage reaches the transmitter on KFD2-STC5-Ex1?
At least 16 V is available at 20 mA and 20 V at 4 mA on terminals 1+ and 3.
03How fast is KFD2-STC5-Ex1?
The settling time is 200 microseconds and the rise and fall time 100 microseconds.
04What ambient temperature does KFD2-STC5-Ex1 allow?
The datasheet gives -20 to 70 degrees C.
05Does KFD2-STC5-Ex1 have test sockets?
Yes, test sockets for connecting HART communicators are integrated into the terminals.