Brand: Parker
Parker P015AA OIL-X Grade AA Replacement Filter Element
Description
P015AA OIL-X grade AA element for PX015 housings
The Parker P015AA is a replacement filter element from the OIL-X range for die-cast aluminium compressed air filters. It is a grade AA element, listed by Parker as AA high efficiency coalescing and dry particulate filtration with a rating of down to 0.01 micron, and it is intended for the P015 family of housings, models PX015B, PX015C. Each box holds one element, and Parker lists a 12 month change interval.
The 015 body is the next size up, with double the rated flow of the 010 body. It suits a short manifold feeding several actuators, small blast guns or a packaging line.
The part number reads as follows: P is the OIL-X element prefix, 015 is the housing size, and AA is the grade. The AA grade provides fine final-stage filtration in a typical multi-stage air line.
P015AA decoded
| Part | Meaning |
|---|---|
| P | OIL-X replacement element |
| 015 | Housing size 015, used in PX015B, PX015C |
| AA | Aa high efficiency coalescing and dry particulate |
P015AA technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Parker / P015AA |
| Product series | OIL-X Genuine Replacement Compressed Air Filter Elements |
| Filter type | AA AA high efficiency coalescing and dry particulate |
| Micron rating | Down to 0.01 micron |
| For use with | PX015 / P015 housings |
| Quantity per box | 1 |
| Number of elements | 1 |
| Element change interval | 12 months |
| Application | Compressed air and nitrogen gas |
| Technology | Filtration |
How the AA stage works in the line
A coalescing element captures fine liquid droplets, merges them into larger drops and lets them run down to the drain, while the same medium holds back dry particles. The AA grade is described by Parker with a rating of down to 0.01 micron. Because the AA grade is the high efficiency one, the OIL-X user guide states that a general purpose filter must always be installed upstream to protect it from bulk liquid aerosols and solid particulate. The user guide also stresses installing filtration at the lowest temperature above freezing, preferably after the aftercooler and receiver.
Housings and flow rates for P015AA
The following figures come from the OIL-X user guide and apply at 7 bar g (100 psi g) referred to 20°C, 1 bar a and 0% relative water vapour pressure.
| Housing model | Port | Flow (l/s) | Flow (m³/h) | Flow (cfm) |
|---|---|---|---|---|
| PX015B | ⅜” | 20 | 72 | 42 |
| PX015C | ½” | 20 | 72 | 42 |
A housing in this size measures 238 mm in height, 89 mm in width and 84 mm in depth, with a weight of 1.41 kg (3.10 lb). Rated flow in m³/min is 1.2.
Pressure and temperature limits for the AA element
| Drain fitted | Operating pressure | Recommended temperature |
|---|---|---|
| Float drain | 1.5 to 16 bar g | 2 to 65°C |
| Manual drain | 1 to 20 bar g | 2 to 80°C |
Housings for AO and AA run with a float drain as standard up to 16 bar g. Between 16 and 20 bar g a manual drain must be used, and Parker advises fitting an external automatic drain on those installations. These limits belong to the housing and the grade, so check them against the plant conditions before ordering.
Selecting the right size around P015AA
Sizing follows the minimum inlet pressure, not the nominal 7 bar value. Take the minimum pressure at the filter inlet, round it down to a whole bar and apply the correction factor from the user guide; the factor is 1.00 at 7 bar g, 1.33 at 5 bar g and 2.00 at 3 bar g. Multiply the real air flow by that factor and select a housing whose rated flow is equal or higher.
- Confirm the housing is a PX015 or P015 unit.
- Match the grade to the duty. Use AA when you need fine final-stage filtration.
- Check whether the line runs above 16 bar g, which needs a manual drain.
- Count the number of installed filters if you want to stock enough spare elements for one service round.
Fitting and servicing a P015AA element
Always depressurise before opening. The user guide describes the sequence: close the inlet and outlet valves, vent through the drain, unscrew the bowl and take out the used element. A strap wrench may be needed on the 050 and 055 bowls. Insert the new element with its lugs seated in the grooves, replace the O-ring in the head with the one supplied, and lubricate threads with an acid-free petroleum jelly.
Refit the bowl and rotate it through 360 degrees until the thread stop (360 for sizes 010 to 030, 720 for 035 to 045 and 540 for 050 to 055). Open the inlet slowly, wait one minute, then open the outlet slowly. Write the next change date on the service label. The AO and AA elements are changed every 12 months or 8736 hours, together with the automatic float drain.
Where the P015AA fits in Oman and the GCC
Typical use in the GCC is a final polishing stage on a branch serving pneumatic actuators and positioners, where the supply has already passed a dryer and a general purpose filter. Oil and gas sites, power stations and desalination plants all rely on clean instrument air, and the combination of heat, dust, salt and humidity in the region loads filters heavily. The annual change schedule is a practical fit with plant shutdown planning.
Related OIL-X grades next to P015AA
| Element | Grade | Rating | Housing |
|---|---|---|---|
| P015AA | AA AA high efficiency coalescing and dry particulate | Down to 0.01 micron | PX015 |
| P015AO | AO AO general purpose coalescing and dry particulate | Down to 1 micron | PX015 |
The user guide also lists the water separator grade WS and the carbon grade ACS for the same bodies. Other sizes in the element family include P010AO, P010AA, P015AA, P020AO, P045AA, P055AA and P055AO, each tied to its own housing size.
Details to send with your RFQ
- Part number P015AA and the quantity of elements.
- Housing model and port size, for example PX015B, with the nameplate details if available.
- Operating pressure, temperature and the drain type fitted.
- Position in the line: before or after the dryer.
- Last change date and the number of elements per service round.
Documents and quotation
An OIL-X user guide covering the WS, AO, AA and ACS grades for the PX010 to PX055 housings is attached on this page. Please send the part number and the housing model, and we will confirm availability and lead time.
Seven Star LLC supplies industrial filtration spares in Oman and the GCC, delivering to Muscat and the industrial regions.
Other Models in the Parker Oilx Px Element Range
Seven Star LLC supplies models from the Parker Oilx Px Element range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Parker P010AO OIL-X Grade AO Replacement Filter Element | Filtration Elements | View details |
| Parker P010AA OIL-X Grade AA Replacement Filter Element | Filtration Elements | View details |
| Parker P015AA OIL-X Grade AA Replacement Filter Element | Filtration Elements | You are viewing this model |
Datasheets & Documents
- Manual Parker OIL-X User Guide (P015AA) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Parker Hannifin is an American manufacturer of motion and control technologies, founded in 1917 in Cleveland, Ohio, by Arthur L. Parker as the Parker Appliance Company. Its first product was a pneumatic brake system for trucks and buses. In 1957 the company bought Hannifin, a maker of hydraulic and pneumatic cylinders and valves, and took the Parker Hannifin name. It is headquartered in the Cleveland area and listed on the New York Stock Exchange.
Seven Star LLC supplies the Parker items that maintenance teams request most: Lucifer solenoid valves, including NAMUR types for actuated valves, along with filter elements and hydraulic gear pumps.
Parker company profile
| Founded | 1917, Cleveland, Ohio, USA, by Arthur L. Parker |
|---|---|
| Headquarters | Cleveland area, Ohio, USA |
| Ownership | Public company, New York Stock Exchange (PH), listed since 1964 |
| First product | Pneumatic brake system for trucks and buses |
| Product families | Hydraulic pumps, cylinders and valves, pneumatic valves and FRLs, instrumentation fittings and valves, hoses and couplings, filtration (including Racor and Velcon), seals and O-rings |
Milestones
- 1917: Arthur L. Parker starts the Parker Appliance Company in Cleveland.
- 1924: Parker restarts the business after a 1919 accident destroyed its inventory.
- 1957: Parker acquires Hannifin and becomes Parker Hannifin.
- 1964: The shares are listed on the New York Stock Exchange.
Parker product lines listed here
Most of the listing is Lucifer, the Parker solenoid valve line that many nameplates still show as a brand in its own right. The 341N types (341N01, 341N22, 341N31) are NAMUR-interface valves that bolt straight onto a pneumatic actuator to pilot it. The E131K03 is a direct-acting 3/2 valve, and the 322K4706 and 7341NAKBHNM0 are further Lucifer solenoid valves. Parker sells Lucifer valve bodies and their coils or electrical parts as separate items, so one body can be combined with different voltages and enclosure types.
Other Parker lines appear: a hydraulic gear pump (P51A478BEY25-07-ZY), a coalescing filter element (9000040001) and a Triple-Lok 37-degree flare tube fitting.
Where Parker components are used
Lucifer NAMUR valves sit on quarter-turn actuators for on-off and shutdown valves in oil and gas, power and water plants across the GCC. Line-mounted solenoid valves switch instrument air, water, steam and light oils on skids and machines. Gear pumps drive hydraulic power units and mobile equipment, and coalescing elements protect instrument air and gas sampling systems from oil and water aerosols.
Parker products we list
Ordering Parker parts: what we need
Parker part numbers are long and every character counts. Please send:
- Solenoid valves: valve number from the body, coil or electrical part number, voltage and frequency, and the Ex marking if the coil is certified
- Gear pumps: the complete code from the nameplate, including the assembly number, which fixes displacement, shaft, ports and rotation
- Filter elements: element number and the housing model it fits
A photo of the nameplate is welcome. We check the code against Parker documentation and identify the manufacturer's current equivalent if a number has been superseded.
Facts checked against Parker's centennial timeline and the Encyclopedia of Cleveland History, October 2026.
Browse Parker products by category: Solenoid Valve, Filtration Elements, Pumps.
FAQ
Questions about the Parker P015AA OIL-X Grade AA Replacement Filter
Answers from our engineering team on installation, compatibility and integration.
01Which housings take the Parker P015AA element?
Parker lists the P015AA for PX015 and P015 housings, which in the OIL-X range means models PX015B, PX015C. Check the nameplate on the housing before ordering.
02What filtration does grade AA offer?
Parker rates the AA grade as AA high efficiency coalescing and dry particulate filtration, down to 0.01 micron. It is fine final-stage filtration, and the AA grade needs a general purpose stage ahead of it.
03How often should the P015AA be replaced?
Parker lists a 12 month element change interval, and the user guide gives 8736 hours, to be done together with the automatic float drain.
04What flow does a PX015 housing handle?
At 7 bar g the PX015B is rated 20 l/s, which is 72 m³/h or 42 cfm. Lower inlet pressures need the correction factor from the guide.
05What is the maximum pressure for housings using P015AA?
With a float drain the range is 1.5 to 16 bar g. With a manual drain it extends to 20 bar g, and an external automatic drain is recommended above 16 bar g.


















Reviews