Brand: Camfil
Camfil CamClose Compact 592x592x96-T5 Coalescing Pre-Filter
Description
A hydrophobic and coalescing pre-filter for turbines and engines
The Camfil CamClose Compact 592x592x96-T5 is a plastic-framed pre-filter for gas turbines, large industrial air compressors, diesel and gas engines, generators and enclosures, and wind turbines, as listed by Camfil. It can be used as a hydrophobic or coalescing air filter stage and is described as suitable for most areas including wet and coastal ones.
That last point matters for Oman and the wider Gulf, where generator and turbine intakes meet salt-laden humid air. The T5 grade is the mid-efficiency option in the three printed grades, rated T5 under ISO 29461, M5 under EN 779 and ePM10 65% under ISO 16890.
Features printed in the datasheet
- Non-discharging, high efficiency media of glass fibre and synthetic material.
- ABS frame; polyurethane and neoprene gasketing; polyurethane sealant.
- Pre-filter with long life and a low and stable pressure drop; high mechanical strength.
- Lightweight and easy to install; can be fitted directly to a final filter with external clips.
- Optional external clips; installation as a separate bank or close-coupled with an external metal clip.
Technical specification
| Parameter | Value |
|---|---|
| Type code | CamClose Compact – 592x592x96-T5 |
| ISO 29461 class | T5 |
| EN 779 / ISO 16890 | M5 / ePM10 65% |
| Dimensions W x H x D | 592 x 592 x 96 mm |
| Nominal airflow | 4,250 m3/h |
| Initial pressure drop | 125 Pa |
| Recommended final pressure drop | 450 Pa |
| Frame | ABS |
| Gasket | Polyurethane; neoprene |
| Media | Glass fibre; synthetic |
| Sealant | Polyurethane |
| Relative humidity | Max 100% |
The datasheet gives media area and weight only on the T2 line (2.3 m2 and 2.5 kg); no figures are printed for the T5, so ask for them if your enclosure design depends on weight.
T2, T5 or T6
| Type | ISO 29461 | EN 779 / ISO 16890 | Initial pressure drop (4,250 m3/h) |
|---|---|---|---|
| 592x592x96-T2 | T2 | G4 / Coarse 70% | 60 Pa |
| 592x592x96-T5 (this page) | T5 | M5 / ePM10 65% | 125 Pa |
| 592x592x96-T6 | T6 | M6 / ePM2.5 50% | 145 Pa |
Moving from T2 to T5 roughly doubles the initial resistance (60 to 125 Pa, derived), and T6 adds a further 20 Pa. The 450 Pa recommended final value is the same for the pre-filter family, so the usable pressure window is widest on the T2 and narrowest on the T6.
Where each grade fits and what to specify
For a gas turbine or engine intake, the pre-filter stage protects the main filter from rain, fog and salt carry-over, which is the reason the sheet stresses the hydrophobic or coalescing role. A higher grade such as T5 captures more fine dust than T2 but at about twice the resistance, so check intake pressure loss limits with the turbine or engine supplier.
To order, quote the exact string CamClose Compact – 592x592x96-T5 with the number of elements per bank, the filter bank frame or close-coupling arrangement, and the final filter model the CamClose will clip to. Confirm the intake temperature limit, as it is not printed on the sheet.
This is a pre-filter, not a final filter, and the sheet makes no claim for sulphur or other gaseous removal.
Practical notes for Gulf power and energy sites
Coastal power plants, desalination plants and offshore-support sites often fit multiple stages on turbine and generator intakes. A close-coupled pre-filter of this kind is placed ahead of the main filter to take rain, mist and dust. This is the reason Camfil lists coastal and wet areas among the suitable locations.
Do not treat a pre-filter rating as proof of protection for the turbine: the final protection depends on the main filter stage that the engine maker specifies.
Fitting and selection notes
Because the frame is built for close-coupling, you can clip the CamClose onto a final filter and avoid a separate holding frame. For a separate bank, use a suitable frame. Where intake air carries fog or rain, the hydrophobic and coalescing function is the reason to specify this series, rather than a standard dry pre-filter.
The datasheet does not give a temperature limit; confirm the operating temperature of the intake with the manufacturer. See other filtration elements.
Fitting and replacement notes
Mount the CamClose Compact in the pre-filter frame of the turbine, compressor or engine intake according to the airflow direction, and make sure the gasketing seals fully. The coalescing stage is intended to capture moisture droplets, so provide a drain path where the installation requires one. Check pressure drop regularly in coastal or humid sites, as salt and moisture load the filter quickly.
Information needed for a quotation
Send the full filter code, the quantity, the housing or frame type it must fit, the delivery location in Oman or the GCC and any prefilters or accessories, so that the complete filter set can be quoted together.
Documents and supply information
The manufacturer data sheet is attached to this page and should be read together with the project specification before a purchase is confirmed. Filter class, airflow, pressure drop and dimensions are quoted as printed on that sheet. Lead time, stock position and certificates available with the shipment are confirmed in the quotation, and we supply to Oman and the wider GCC region for industrial, utility and building services projects.
Frequently asked questions
What equipment is it intended for? Gas turbines, large industrial air compressors, diesel and gas engines, generators and enclosures, and wind turbines.
What class is the T5 grade? T5 under ISO 29461, M5 under EN 779 and ePM10 65% under ISO 16890.
What airflow is printed? 4,250 m3/h at 125 Pa initial pressure drop.
Is it suitable for coastal sites? Camfil lists it as suitable for most areas including wet and coastal.
Is Seven Star LLC the manufacturer? No. Seven Star LLC is an independent supplier in Muscat; confirm the exact type, size and class with the datasheet before ordering.
Datasheets & Documents
- Datasheet Camfil CamClose Compact data sheet (EN) Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Camfil is a Swedish air filtration company that has worked on clean air since 1963 and is headquartered in Stockholm. It supplies filters and filtration systems for commercial and industrial air handling, cleanrooms, air pollution control, molecular contamination control and gas turbine and engine air intakes.
Seven Star LLC is an independent supplier in Muscat. We list Camfil filters against the exact type code on the Camfil data sheet, for HVAC contractors, facility teams and plant engineers in Oman and the GCC.
Camfil product series
Bag filters include the Cam-Flo ES ePM1 70%, the Basic-Flo ePM10 70% economy bag, the Hi-Cap CO60 coarse prefilter and the City-Flo ePM1 85% bag with activated carbon for urban air. The 30/30 panel prefilter is a pleated ePM10 50% filter for the first stage of an air handling unit.
Compact and box filters include the Opakair F8 and Airopac F7 filters, and HEPA filters include the Absolute VG H13 compact filter and the Megalam ProSafe MX14 H14 panel for cleanrooms and controlled environments. The CamClose compact coalescing pre-filter protects gas turbine and engine intakes against salt and moisture.
Where Camfil filters are used
Air handling units in offices, malls, hospitals and hotels, cleanrooms and laboratories, pharmaceutical and food plants, data centres, and gas turbine and compressor air intakes, where dust and humidity in the Gulf climate shorten filter life.
Ordering Camfil filters: what we need
Send the Camfil type code, or the filter class (ISO 16890 ePM rating or EN 1822 HEPA class), the face size and depth, the number of pockets for bag filters, the frame material, the airflow and the quantity. A photo of the label on the old filter usually gives all of this.
Browse Camfil products by category: Filtration Elements.
Related products
Frequently Asked Questions
Gas turbines, large industrial air compressors, diesel and gas engines, generators and enclosures, and wind turbines.
T5 under ISO 29461, M5 under EN 779 and ePM10 65% under ISO 16890.
4,250 m3/h at 125 Pa initial pressure drop.
Camfil lists it as suitable for most areas including wet and coastal.
No. Seven Star LLC is an independent supplier in Muscat; confirm the exact type, size and class with the datasheet before ordering.