Brand:

MSA PrimaX IR Point Infrared Gas Transmitter (HART, SIL 2)

Description

MSA PrimaX IR point infrared gas transmitter explained

The MSA PrimaX IR is a fixed point infrared gas transmitter that measures flammable hydrocarbon vapour as a percentage of the lower explosive limit and sends a 4-20 mA signal, with HART digital communication for set-up and diagnostics. It has a dual-source optical design, heated optics and a 316 stainless steel IP67 body, and it is designed for SIL 2 safety-system integration. Seven Star LLC is an independent supplier in Muscat and supplies MSA fixed gas detectors in Oman and the GCC; we are not affiliated with the manufacturer.

The PrimaX IR is ordered by target gas, approval agency, thread, junction box and mounting style, so this page decodes that ordering matrix and lists the accessories shown on the manufacturer order form.

PrimaX IR technical specifications

Parameter Specification
Manufacturer / part number MSA / PrimaX IR gas transmitter (infrared point detector, ordered by ATO code A-PRIMAXIR)
Measurement Flammable gas, 0-100 %LEL
Output 4-20 mA analogue with HART digital communication
Optical design Dual source for redundancy; heated optics prevent condensation build-up
Housing 316 stainless steel, IP67
Safety integration SIL 2 design
Sensor supply voltage 18-32 VDC measured at the sensor
Weight Sensor 1.5 kg; aluminium junction box 0.8 kg; bracket 0.32 kg; combined 2.74 kg
Maximum cable length at 24 VDC (500 ohm load) 480 m with 1.0 mm2; 720 m with 1.5 mm2
Calibration One-person calibration with a calibration cap; factory-calibrated for fast commissioning

PrimaX IR ordering matrix explained

The order form builds the model code from numbered positions. Understanding each position avoids ordering the wrong gas or thread.

Position Meaning Options listed
1 Target gas Calibration gas and range 14 = methane 0-100 %LEL (5.0 %vol); 15 = propane 0-100 %LEL (2.1 %vol)
2 Approval agency Certification body F = FM
3 Thread type Conduit thread N = NPT
4 Unused Reserved 0 = none
5 Junction box Wiring box 0 = none; 3 = 316 stainless steel explosion-proof box (includes bracket)
6 Mounting style How the sensor attaches 0 = none; 1 = sensor attached to junction box (only if position 5 = 3)
7 Future expansion Reserved 0 = none
8 Custom Special operation 0 = none; C = custom operation

How the PrimaX IR measures gas

Two infrared sources provide redundancy, so a single source failure does not leave the detector blind. Heated optics keep condensation off the optical surfaces, which matters in humid coastal air and during temperature swings between day and night. An environmental guard housing improves response time while protecting the optics. The manufacturer lists many target gases for this transmitter, including methane, ethane, propane, butane, isobutane, pentane, hexane, cyclopentane, ethylene, propylene, propylene oxide, acetone, ethyl acetate, toluene and xylene, but the ordering matrix on the current form offers methane and propane factory calibration, so confirm other gases with the supplier.

PrimaX IR accessories and spares

Part number Item
10113100 Flow cap, 316 stainless steel
10114373 Duct-mount kit, 316 stainless steel
10114097 Environmental guard tether, 316 stainless steel
10119593 HART junction box, 316 stainless steel
10116418 Insect guard, 316 stainless steel
10113481 Sunshield, 316 stainless steel
10111874 Calibration cap with display
10081441 Universal HART cable
10122228 Blind calibration cap for use with a HART field communicator
10122783 Remote calibration adapter

PrimaX IR selection checklist

  • Target gas: methane or propane on the current order form, and the calibration gas to be used on site.
  • Approval agency and conduit thread (FM and NPT are shown on the form).
  • Whether a stainless junction box and bracket are needed, and whether the sensor attaches directly to it.
  • Sunshield for exposed outdoor installation, insect guard for areas with insects, flow cap for calibration, duct-mount kit for duct monitoring.
  • Controller input: 4-20 mA with HART, loop resistance and cable run length against the supply voltage.
  • Calibration method: calibration cap with display, blind cap with a HART communicator, or a remote calibration adapter.

Installation and maintenance of the PrimaX IR

Mount the sensor with its legs horizontal for best performance, ground the junction box to earth and keep the cable within the length limit for the chosen wire size. Fit the sunshield where direct sun heats the housing, and remove spider webs and insects from the guard at regular intervals. Commission with a zero check and a span check using the correct gas, record the HART configuration and keep the date of the last calibration. The PrimaX IR Link software and device description files are listed by the manufacturer for HART tools.

Typical PrimaX IR applications in Oman and the GCC

In Oman and the GCC infrared point detectors such as the PrimaX IR protect oil and gas wellheads, compressor houses, separators, loading areas, fuel gas skids and power plant gas trains, where fast hydrocarbon detection with SIL 2 capability is required. The stainless steel IP67 housing and heated optics suit outdoor installations in heat, dust and humidity.

Information to send with a PrimaX IR RFQ

  • Target gas and calibration gas
  • Approval and thread type
  • Junction box and mounting style
  • Accessories required, such as sunshield or calibration cap
  • Controller and HART requirements
  • Delivery location and date

Storage, handling and spares for the MSA PrimaX IR

Store the MSA PrimaX IR and its sensors as described in the manufacturer instructions, in a clean, dry place within the stated temperature range. Some gas sensors have a limited shelf life, so plan deliveries close to the installation date. In Oman and the GCC, avoid storing detectors and calibration gas in hot containers or in direct sun.

  • Bump test or calibrate the detector with certified test gas at the interval set by your site safety procedure.
  • Check hazardous area certificates and markings against the zone classification before installation.
  • Keep spare sensors, filters and calibration gas for planned maintenance.
  • Record test and calibration results for each detector tag number.

When you send an RFQ for the MSA PrimaX IR, include the target gases, ranges, area classification and any calibration kit you need, so the full scope can be quoted together.

Documents and quotation

The manufacturer ordering form for the PrimaX IR is attached on this page and shows the model code positions and accessory part numbers.

Send us the gas, approval and accessory list and we will prepare a quotation. Seven Star LLC supplies the PrimaX IR in Oman and the GCC as an independent supplier.

Other Models in the Msa Ultima Fixed Range

Seven Star LLC supplies models from the Msa Ultima Fixed range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
MSA Ultima XIR Infrared Combustible Gas Monitor (legacy)Fire & Gas DetectorsView details
MSA PrimaX IR Point Infrared Gas Transmitter (HART, SIL 2)Fire & Gas DetectorsYou are viewing this model
Datasheets & Documents
  • PDF Catalog MSA PrimaX IR Ordering Form Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

MSA Safety is an American maker of safety equipment, founded in 1914 in Pittsburgh by mining engineers John T. Ryan and George H. Deike as Mine Safety Appliances Company, after a series of deadly mine disasters. It first supplied miners with electric cap lamps and breathing apparatus. MSA is headquartered in Cranberry Township, Pennsylvania, and listed on the New York Stock Exchange.

Seven Star LLC supplies MSA gas detectors and accessories in Oman, covering both sides of the product line: ALTAIR portable detectors worn by technicians, and fixed gas monitors such as the ULTIMA X5000 and General Monitors S5000 that feed a fire and gas system.

MSA Safety company profile

Founded 1914, Pittsburgh, Pennsylvania, USA
Founders John T. Ryan and George H. Deike
Original name Mine Safety Appliances Company
Headquarters Cranberry Township, Pennsylvania
Listing New York Stock Exchange (MSA)
Product families ALTAIR 4XR and ALTAIR io portable gas detectors, ULTIMA X5000 and General Monitors fixed gas and flame detection, G1 SCBA, V-Gard helmets, V-Series and V-FORM fall protection harnesses and lifelines

MSA gas detection families listed here

On the portable side, the ALTAIR 4XR is the four-gas detector for combustible gas, oxygen, carbon monoxide and hydrogen sulfide, and the ALTAIR io4 is the connected version that reports readings to a cloud platform. The GALAXY GX2 automated test system handles bump tests and calibration records for ALTAIR instruments.

On the fixed side, the ULTIMA X5000 and General Monitors S5000 are transmitters for combustible, toxic and oxygen sensors. Many installed units still carry the General Monitors name on the nameplate. The Chillgard 5000 is a refrigerant leak monitor for machinery rooms. Small consumables are listed too, such as window cleaning solution 10272-1.

Where MSA gas monitors are used

Fixed MSA gas monitors are found on wellheads, gas plants, refineries, tank farms, LNG and petrochemical units, wherever hydrocarbon or H2S leaks must be alarmed early. Portable ALTAIR detectors go with crews into confined spaces and on hot work permits. Chillgard monitors serve chiller plant rooms in district cooling and large buildings, a common application in the GCC.

MSA Safety products we list

Family Examples
Fire & Gas Detectors MSA ALTAIR 4XR Multigas Detector, MSA ALTAIR io4 Connected Multi-Gas Detec…, MSA General Monitors S5000 Gas Monitor, Window Cleaning Solution 10272-1, MSA Ultima X5000 Gas Monitor
Gas Analyzer Systems MSA Chillgard 5000 Refrigerant Monitor
Gas Analyzer Accessories MSA GALAXY GX2 Automated Test System

Ordering MSA detectors and sensors: what we need

Fixed gas monitors are configured items. Send the full part number or the configuration code from the nameplate, the target gas and range, the sensor technology (catalytic, infrared, electrochemical), the housing material, the output (4-20 mA with HART, optional relays) and the hazardous area approval required. For portables, state the sensor combination, charger type and regional version. For replacement sensors, a nameplate photo of the transmitter avoids mistakes. We check each code against MSA documentation and propose the manufacturer's current model when an older one is no longer made.

Facts checked against MSA Safety's corporate history and investor materials, October 2026.

FAQ

Questions about the MSA PrimaX IR Point Infrared Gas Transmitter (HART,

Answers from our engineering team on installation, compatibility and integration.

01What does the PrimaX IR measure?
It measures flammable hydrocarbon gas in the range 0-100 %LEL using infrared detection. The order form offers methane (code 14) and propane (code 15) as factory target gases.
02What output does the PrimaX IR provide?
It provides a 4-20 mA analogue output with HART digital communication for set-up, calibration diagnostics and maintenance. The sensor needs 18-32 VDC measured at the sensor.
03Is the PrimaX IR SIL rated?
The manufacturer describes a SIL 2 design that provides safety-system integration capability. For a certified SIL application, confirm the certificate and safety manual for your configuration.
04What is the housing made of?
The sensor housing is 316 stainless steel rated IP67. An optional 316 stainless steel explosion-proof junction box with bracket can be ordered, and the sensor can be attached directly to it.
05How is the PrimaX IR calibrated?
One person can calibrate it with a calibration cap, either the version with display or a blind cap used with a HART field communicator. A remote calibration adapter is also listed.