Brand:

Metrohm 902 Titrando Intelligent Potentiometric Titrator

Description

Overview

The Metrohm 902 Titrando is a compact potentiometric titrator from the Titrando line of Metrohm, the Swiss analytical instrument maker based in Herisau. It is the entry point of the high-end Titrando family: one galvanically isolated measuring interface, four MSB sockets and a housing only 142 mm wide. Metrohm describes it as a unit for endpoint titration (SET), enzymatic and pH-STAT titrations (STAT), and it can be extended later with a second measuring interface. Seven Star LLC is an independent supplier serving Oman and the GCC.

Buyers in Oman usually look for this titrator when a laboratory needs repeatable acid-base, redox or ion-selective titrations and must keep the audit trail demanded by quality systems. The instrument works with OMNIS software, tiamo software or the 900 Touch Control, so the same hardware can run as a stand-alone bench titrator or as a node in a networked laboratory.

Key features of the 902 Titrando

  • Control of up to four dosing systems of the 800 Dosino type, each mounted directly on the titrant bottle.
  • Dosing functions with monitoring, liquid handling and tandem dosing for synchronised additions.
  • Four MSB connectors for further stirrers, dosing devices and Remote Boxes.
  • A USB controller port with auxiliary power for a Touch Control or a computer, plus two USB host ports.
  • Support for iTrodes through the 854 iConnect, which carries calibration data inside the electrode head.
  • Compliance support for GMP, GLP and FDA 21 CFR Part 11 when the matching software option is used.

Metrohm 902 Titrando technical specifications

Parameter Value for the Metrohm 902 Titrando
Order number 2.902.0010
Measuring interface One galvanically isolated interface
Measuring cycle 100 ms in every measuring mode
Input resistance Above 1 x 10 to the power 12 ohm
Offset current Below 1 x 10 to the power minus 12 A
pH range and resolution minus 13 to plus 20 pH, 0.001 pH
pH accuracy plus or minus 0.003 pH
Voltage range and resolution minus 1,200 to plus 1,200 mV, 0.1 mV
Voltage accuracy plus or minus 0.2 mV
Temperature input Pt1000 minus 150 to plus 250 degrees C; NTC minus 5 to plus 250 degrees C
Supply 100 to 240 V, 50 to 60 Hz, maximum 45 W
Housing 142 x 227 x 231 mm, 2.7 kg, polybutylene terephthalate
Ambient conditions 5 to 45 degrees C, up to 80 percent humidity, non-condensing

How the 902 Titrando differs from other Titrando variants

Within the family the numbers matter. The 902 has no internal dosing drive: every titrant is delivered by an external Dosino or Dosimat, and it accepts up to four of them on MSB 1 to MSB 4. The 904 Titrando, by contrast, houses one internal drive for an exchange unit and therefore leaves only three MSB sockets for external dosing devices. The 902 also lacks the polarizer input found on the 904 and 907, so it covers potentiometric work, not voltammetric or biamperometric end-point detection. If your methods only need pH, millivolt or ion-selective measurement, the 902 is the lean choice; if you need a polarizable electrode input, look at the 904 or 907 instead.

Measuring performance in practice

The high-ohm input, with input resistance above 10 to the 12 ohm and offset current under 10 to the minus 12 A, suits glass pH membranes and fragile ion-selective electrodes alike. A resolution of 0.001 pH with 0.003 pH accuracy (without sensor error, under reference conditions) lets the analyst resolve the steep part of an endpoint curve. Temperature compensation uses a Pt1000 or an NTC probe; the NTC characteristic can be configured with its R value at 25 degrees C and its B value, so third-party thermistors can be used.

Applications in Oman and the GCC

Power and desalination plants measure alkalinity and chloride in cooling and boiler water. Refineries and petrochemical laboratories determine acid number and base number in lubricants and fuels. Food, beverage and pharmaceutical producers run assay titrations, and municipal water laboratories follow hardness and alkalinity. Because the instrument supports pH-STAT mode, enzyme activity tests and neutralisation control during synthesis are also possible. In hot coastal sites the nominal operating range of 5 to 45 degrees C means the laboratory still needs air conditioning, which is worth noting when planning a bench location.

Selection and compatibility notes

Before you order, decide how the titrator will be operated. A 900 Touch Control gives a stand-alone titrator with favorites and PDF reports; OMNIS or tiamo software on a PC adds database storage and parallel titration. The Titrando links to USB Sample Processors, Robotic Titrosamplers and the Dosing Interface, so the lab can automate later without replacing the base unit. Check the electrode type too: ordinary electrodes connect to the Ind., Ref. and Temp. sockets, while iTrodes need the 854 iConnect. Printers, keyboards, barcode readers and an RS-232 to USB box connect to the two USB host ports.

Installation and commissioning

Place the unit on a stable bench away from direct sunlight and strong magnetic fields. Connect the controller cable or the Touch Control cable, then attach dosing devices and stirrers to the MSB sockets; the system performs a self-diagnosis each time it is switched on. Condition and calibrate the electrode with fresh buffer solutions, and record the result. The unit uses electronic overload protection, so there is no user-replaceable mains fuse. Update the device software through the PC software when a newer version is offered.

Maintenance and care

Most routine work concerns the periphery. Rinse the dosing unit and tubing with the prep command after changing titrant, empty the cylinder before storage, inspect the transparent Dosino housing for bubbles, and keep electrode diaphragms moist. Wipe the PBT housing with a damp cloth only. Metrohm advises keeping the printed accessories list together with the manual so that replacement items are ordered under the correct article number.

Ordering notes for Metrohm 902 Titrando

State the full designation Metrohm 902 Titrando and, if known, order number 2.902.0010 on your request. Tell us whether you also need dosing units, a stirrer or titration stand, a Touch Control and electrodes, so that one quotation covers the whole titration station. We can also quote the iConnect and electrodes of your choice. Delivery to Oman and other GCC sites is handled by Seven Star LLC after confirmation of the configuration.

Related items you may also need: Metrohm 916 Ti-Touch Compact Potentiometric Titrator | Metrohm 2035 Process Analyzer | Metrohm 905 Titrando Potentiometric Titrator | All Metrohm products.

Points to confirm for the Metrohm 902 Titrando

  • If the Metrohm 902 Titrando is a like-for-like replacement, read the full code from the installed nameplate and compare it with this page.
  • For each Metrohm 902 Titrando request we confirm the exact code, new or surplus condition and lead time in writing.
  • Dimensions, ratings and connection data for the Metrohm 902 Titrando are in the datasheet attached to this page.
  • The Metrohm 902 Titrando belongs to our liquid analytical systems range and can be delivered to Muscat, Sohar, Duqm and other GCC locations.

Documents and quotation

The manufacturer brochure for the Metrohm 902 Titrando is attached to this page as a datasheet. Please send your RFQ with the part number Metrohm 902 Titrando, the quantity, the intended application and your delivery location in Oman or the GCC, and our team will reply with availability and lead time.

Datasheets & Documents
  • PDF Datasheet Metrohm 902 Titrando Intelligent Potentiometric Titrator Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Metrohm is a Swiss maker of instruments for chemical analysis, founded in 1943 by Bertold Suhner in Herisau, where it is still headquartered. It is best known for titration and also makes ion chromatography, electrochemistry, spectroscopy and process analysers. Metrohm is owned by a foundation.

Seven Star LLC lists the Metrohm 905 Titrando, the 916 Ti-Touch and the 2035 Process Analyzer, and supplies Metrohm instruments and accessories to laboratories and plants in Oman and the GCC.

Metrohm company profile

Founded 1943, Herisau, Switzerland
Founder Bertold Suhner
Headquarters Herisau, Switzerland
Ownership Metrohm Foundation
Product families Titrando and Ti-Touch titrators, ion chromatography systems, 2035 and 2060 process analysers, electrodes

Metrohm instruments listed here

The 905 Titrando is a high-end potentiometric titrator for use with Dosino dosing units. It runs dynamic (DET), monotonic (MET) and set endpoint (SET) titrations, takes up to four 800 Dosino units, recognizes intelligent iTrode electrodes, and is operated from tiamo or OMNIS software or a Touch Control. The 2035 Process Analyzer is an online wet-chemistry analyzer for automatic analysis of samples drawn from the process.

Metrohm products we list

Family Examples
Liquid Analytical Systems 2035 Process Analyzer, 905 Titrando Potentiometric Titrator, 916 Ti-Touch Compact Potentiometric Titr…

Ordering Metrohm equipment: what we need

Metrohm article numbers follow a fixed pattern (the 905 Titrando is 2.905.0010), and that number is the best reference for instruments, electrodes and accessories. For a new application, tell us the sample, the parameter and its concentration range, the method or standard you follow, and for a process analyzer the number of sample streams and the signals your control system needs.

Facts checked against Metrohm's published company history, October 2026.

FAQ

Questions about the Metrohm 902 Titrando Intelligent Potentiometric

Answers from our engineering team on installation, compatibility and integration.

01Does the Metrohm 902 Titrando have an internal dosing drive?
No. All titrant is dispensed by external 800 Dosino or Dosimat units; up to four can be connected to the MSB sockets.
02Can the 902 Titrando use a polarizable electrode?
The 902 specification lists only potentiometry and temperature inputs. Polarizable electrode input is found on the 904 and 907 Titrando instead.
03What power supply does the 902 Titrando need?
It works on 100 to 240 V at 50 to 60 Hz with a maximum power consumption of 45 W and electronic overload protection.
04Which software or controller runs the 902 Titrando?
It is operated by the 900 Touch Control for stand-alone use or by OMNIS or tiamo software on a computer through the USB controller port.
05What are the dimensions and weight of the 902 Titrando?
The housing measures 142 mm wide, 227 mm high and 231 mm deep and weighs 2.7 kg without accessories.