Brand:

Georg Fischer Type 515 Spigot End Diaphragm Valve

Description

Overview

Georg Fischer Type 515 is the spigot end member of the GF 5-Series manual diaphragm valves. It has no unions: the valve body ends in plastic spigots that are welded or bonded straight into the pipe, which gives a compact, permanently tight installation with the fewest possible leak points. Sizes run from d20 (DN15, 1/2 inch) to d63 (DN50, 2 inch). Seven Star LLC is an independent supplier serving Oman and the GCC.

Connection types listed for Georg Fischer Type 515

The datasheet offers solvent cement spigots, socket fusion spigots and butt fusion spigots, so the same valve can be joined into PVC, PP or PVDF systems with the method that suits the pipe. The body can be PVC-U, PVC-C, ABS, PP-H, PP-N, PVDF, PVDF-HP or PEEK at PN10, and PVC-U, PVDF, PVDF-HP or PEEK at PN16. PEEK is unique to this and the three way type in the series, and it is used where the temperature and chemical load are beyond PVDF.

Technical table for Georg Fischer Type 515

Item Datasheet value
Connection Spigots: solvent cement, socket fusion or butt fusion
Sizes d20 to d63, DN15 to DN50, 1/2 to 2 inch
Body materials PN10 PVC-U, PVC-C, ABS, PP-H, PP-N, PVDF, PVDF-HP, PEEK
Body materials PN16 PVC-U, PVDF, PVDF-HP, PEEK
Kv 100, d25 / DN20 271 l/min, 16 cubic metres per hour (Cv 19)
Kv 100, d40 / DN32 759 l/min, 45 cubic metres per hour (Cv 52)
Kv 100, d63 / DN50 1728 l/min, 104 cubic metres per hour (Cv 119)
Pressure levels PN10 and PN16, depending on body and housing nut material
Housing nut PPGF 30 orange as standard; PPSGF40 black for water applications with PN16
Diaphragm materials NBR, EPDM, PTFE, FKM
Gasket materials EPDM, FKM
Temperature, PVC-U 0 to 60 degrees C
Temperature, PVC-C and PP 0 to 80 degrees C
Temperature, ABS Minus 30 to plus 60 degrees C
Temperature, PVDF and PEEK Minus 20 to plus 140 degrees C
Product standard EN ISO 16138
Test standards ISO 9393-2 and EN 12266-1, leakage rate A

How Georg Fischer Type 515 differs from Types 514 and 517

Where the Type 514 has unions and can be taken out of the line in minutes, the Georg Fischer Type 515 is meant to stay in place and only the top works are serviced, which in a diaphragm valve is where the diaphragm sits. Where the Type 517 has flanges for bolting to metal or plastic flanged pipe, the Georg Fischer Type 515 has no bolted joints at all. The smallest size is d20 against d16 on the Type 514, and PEEK and PP-N bodies are available which the union type does not list.

Use in Oman and GCC process plants

Welded spigot valves are common in fixed chemical dosing skids, desalination pre-treatment and post-treatment, acid cleaning lines, ultrapure water loops and wastewater treatment works. The absence of unions means no threads to leak, which lowers risk with hazardous chemicals. PVDF and PEEK bodies handle hot or concentrated media such as hypochlorite or hot acids.

Fitting the spigot valve

Cut the pipe square, clean the surfaces and prepare the weld or bond exactly as the pipe maker’s procedure demands. Hold the valve so that no bending load is transferred to the spigots while the joint cools, and support the pipe on both sides. Never weld or bond with the diaphragm assembly in place on hot jobs where heat could reach it; where practical, the top works can be removed first. Open the valve a little during pressure tests to avoid trapping air.

Servicing the top works

The housing nut and diaphragm can be changed with the valve still in the line, after depressurising, which is the main reason the spigot design remains practical. Replace the diaphragm when you see cracking, swelling or hardening. The datasheet lists spare parts and accessories, including position indicators and limit switches.

Approvals and standards

The valve complies with product standard EN ISO 16138 and is tested to ISO 9393-2 and EN 12266-1 for leakage rate A. Approvals listed are ACS, FDA and DIBt, and the datasheet notes that some certification is temporarily unavailable while requalification is in progress, so check the status for your project.

Selection data to supply

State the size, body material, joining method, diaphragm and gasket material, pressure level and the medium with its concentration and temperature. Mention whether you will automate the valve later with a DIASTAR or e-DIASTAR actuator.

Cost of ownership of a welded valve

A spigot valve costs less to install than a union valve in a permanent line, since there are no union nuts or o-rings to buy, track or retighten. Over the life of a plant, however, the diaphragm will be replaced several times, and the housing nut design of the Georg Fischer Type 515 lets this be done without cutting the pipe. Compared with a ball valve, the diaphragm valve gives more precise throttling and no trapped liquid in a body cavity, and for contaminated or slurry media the full bore weir path is easier to flush. These points often outweigh a small difference in purchase price, in particular for plants that dose chemicals around the clock in the heat of the Gulf, where long service life reduces shutdowns.

Pre-delivery checks

On receipt, check the type, size and body material marked on the valve, the colour of the housing nut, the diaphragm and gasket material, and make sure that the protective caps stay on until installation so dust cannot enter the body. Store the valve closed lightly, never fully tightened, so the diaphragm does not take a set.

Related items you may also need: GF Signet 3-2551 Magmeter Insertion Electromagnetic Flow Sensor | GF Type 567 Wafer Thermoplastic Butterfly Valve | GF Type 546 Pro Linear Thermoplastic Ball Valve | All Georg Fischer products.

Documents and quotation

The GF datasheet covering the Georg Fischer Type 515 is attached, with flow data, pressure and temperature diagrams and ordering dimensions. Send your RFQ with the Georg Fischer Type 515 size, body material, quantity and delivery location in Oman or the GCC.

Other Models in the Gf 5series Range

Seven Star LLC supplies models from the Gf 5series range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.

ModelCategory
Georg Fischer Type 514 Manual Diaphragm Valve with UnionsGlobe ValvesView details
Georg Fischer Type 515 Spigot End Diaphragm ValveGlobe ValvesYou are viewing this model
Datasheets & Documents
  • PDF Datasheet Georg Fischer Type 515 Spigot End Diaphragm Valve Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Georg Fischer (GF) is a Swiss industrial group founded in 1802, when Johann Conrad Fischer bought a mill near Schaffhausen and turned it into a foundry. In 1864 his grandson Georg Fischer began making malleable iron fittings, introducing the GF fish trademark, and piping is one of the company's oldest businesses. GF Piping Systems makes plastic and metal piping systems, valves and Signet flow and water quality instruments.

Seven Star LLC, an independent supplier in Oman, lists the GF Signet 3-2551 Magmeter insertion electromagnetic flow sensor and the GF Signet 8550-1 flow transmitter.

Georg Fischer company profile

Founded 1802, Schaffhausen, Switzerland
Founder Johann Conrad Fischer
Headquarters Schaffhausen, Switzerland
Piping business Fittings since 1864
Product families Type 546 ball valves, Type 567 butterfly valves, Signet flow sensors and transmitters, thermoplastic pipes and fittings

Milestones

  • 1802: Johann Conrad Fischer founds the company.
  • 1864: GF begins making malleable iron fittings.

GF Signet instruments listed here

The 3-2551 Magmeter is an insertion flow sensor: it is mounted through a fitting in the pipe wall, has no moving parts and needs a liquid with some electrical conductivity. The 8550-1 is a flow transmitter that takes the signal from a Signet flow sensor and provides a display and outputs for the control system. Sensor, pipe fitting and transmitter are chosen together, because the fitting sets the insertion depth for a given pipe size and material.

Georg Fischer products we list

Family Examples
Flowmeters GF Signet 3-2551 Magmeter Insertion Elec…, GF Signet 8550-1 Flow Transmitter
Ball Valves GF Type 546 Pro Linear Thermoplastic Bal…
Butterfly Valves GF Type 567 Wafer Thermoplastic Butterfl…

Ordering GF Signet parts: what we need

Copy the manufacturer part number from the label, which normally starts with 3- followed by the model and option digits. Add pipe size, pipe material, the fitting you have, the fluid and its conductivity, sensor body material, output required and cable length. Water treatment, desalination and chemical dosing sites in the GCC often have older Signet transmitters; if a model is no longer produced we ask for the manufacturer's current replacement, which for the 8550 is listed by distributors as the Signet 9900.

Facts checked against the Historical Dictionary of Switzerland and GF histories, October 2026.

FAQ

Questions about the Georg Fischer Type 515 Spigot End Diaphragm Valve

Answers from our engineering team on installation, compatibility and integration.

01What connections does Georg Fischer Type 515 have?
Spigot ends for solvent cement, socket fusion or butt fusion joining, with no unions.
02What size range does Georg Fischer Type 515 cover?
It covers d20 to d63, which is DN15 to DN50 or 1/2 to 2 inch.
03Does Georg Fischer Type 515 come in PEEK?
Yes, PEEK bodies are listed at both PN10 and PN16 for this type.
04What is the Kv of Georg Fischer Type 515 at d32?
For the d32 DN25 valve, Kv 100 is 481 l/min or 29 cubic metres per hour, with a Cv of 33.
05What standards apply to Georg Fischer Type 515?
Product standard EN ISO 16138, tested to ISO 9393-2 and EN 12266-1 with leakage rate A.