- Automation & ControlView all 2,082 products
- AC Drives
- Automation Accessories
- PLC & I/O Cards
- Industrial Communications
- Vibration Monitoring
- Controllers & Data Acquisition
- Isolator & Barrier
- CCTV & Security
- Safety Switches & Guard Locking
- Encoders
- HMI Displays
- Motor Soft Starters
- Pneumatic Cylinders
- Industrial Computers
- Servo Drives
- Machine Vision
- Automation Software
- Robotics
Brand: Fluke
Fluke 287 True-RMS Electronics Logging Multimeter
Description
287 logging multimeter with TrendCapture explained
The Fluke 287 True-RMS Electronics Logging Multimeter (287) is a high-resolution true-RMS multimeter with on-board logging and a graphical TrendCapture display. A 50,000-count screen, 0.025% basic DC accuracy and a 100 kHz AC bandwidth make it a handheld alternative to a bench meter. Seven Star LLC supplies 287 in Oman and the GCC as an independent supplier in Muscat, not affiliated with the manufacturer.
The 287 is the electronics-oriented member of the 280 series. The table decodes its main identifiers.
| Element | Value | Meaning |
|---|---|---|
| 287 | Model | Electronics logging multimeter, 280 series |
| TrendCapture | Graphical logging | Trends shown on the meter without a PC |
| 50,000 counts | Resolution | 1/4 VGA display with backlight |
| 0.025% | Basic DC accuracy | Voltage function |
287 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / part number | Fluke / 287 |
| DC voltage | 50 mV to 1000 V, basic accuracy 0.025% |
| AC voltage (true-RMS) | 50 mV to 1000 V, 0.4%; bandwidth 100 kHz |
| DC current | 500 µA to 10 A, 0.05% |
| AC current (true-RMS) | 500 µA to 10 A, 0.6% |
| Resistance | 500 Ω to 500 MΩ, 0.05% |
| Capacitance | 1 nF to 100 mF, 1.0% |
| Frequency | Up to 999.99 kHz, 0.005% |
| Temperature (excl. probe) | -200 °C to 1350 °C, 1.0% |
| Logging memory | Up to 10,000 readings; 15,000 recorded events stored |
| Battery | 6 AA alkaline, 100 hours minimum, 200 hours in logging |
| Size / weight | 22.2 x 10.2 x 6 cm / 870.9 g |
| Peak capture | 250 µs |
Data from the manufacturer product page and datasheet for the Fluke 287. Wireless use needs the optional ir3000 FC connector.
How the Fluke 287 True-RMS Electronics Logging Multimeter works
The 287 samples at high resolution and stores readings internally. TrendCapture plots them on the 1/4 VGA screen so that an intermittent fault or a slow drift can be seen immediately, and zoom lets the user magnify the trend up to 14 times without downloading to a PC.
A selectable AC filter smooths noisy readings, adjustable thresholds decide when a new event starts, and a real-time clock time-stamps saved measurements. Named saved measurements can be recalled later in the field.
Key features
- 50,000-count 1/4 VGA display
- Zoom on trend, up to 14 times
- Up to 10,000 logged readings
- Real-time clock time stamps
- 100 mF capacitance range
Where 287 fits and related Fluke models
The 287 sits between the 28 II rugged meter and the 289 industrial logging meter in capability. The 289 adds industrial features such as a low-pass filter for drives; the 287 is aimed at electronics and design validation.
For simple go/no-go field use, the 17x series is lighter and cheaper.
Selection checklist for 287
Confirm the following points before ordering, so that the instrument matches the work and the safety rules of your site.
- Logging needs and the number of readings per session.
- Resolution and accuracy needs that justify 50,000 counts.
- Battery type: six AA cells.
- Wireless connection requires an optional adapter.
Safe use, care and maintenance of 287
- Before each shift, inspect the case, the holster and the test leads. Cracked insulation, exposed metal or a loose input jack means the leads should be replaced before the 287 touches any live circuit.
- Confirm the meter on a known live source before and after a measurement that decides whether a circuit is dead. Never rely on a single reading when the result will be used to release a lock-out.
- Keep the input fuses to the specified type only. A blown fuse in the current inputs is the most common service event on a multimeter used on motor circuits, and a wrong fuse defeats the safety design of the Fluke 287 True-RMS Electronics Logging Multimeter.
- Replace the battery when the low-battery symbol appears, because readings near the lower end of the range become unreliable on a weak cell. Remove the battery before long storage.
- Store the instrument clean and dry. In coastal Oman, wipe off salt film and condensation after outdoor use and avoid leaving it in a vehicle cabin in summer.
Typical applications of 287 in Oman and the GCC
Handheld multimeters are carried in every plant. In Oman, oil and gas facilities, power stations, desalination plants and petrochemical sites rely on them for control-panel faults, motor circuits, instrument loops and routine electrical checks.
In Oman the 287 is used in instrumentation workshops, calibration labs and commissioning teams verifying control loops, power supplies and sensors. Logging helps document transients and slow drifts at plants where permanent monitoring is not available.
287 compared with nearby models
| Model | DC accuracy | Display | Logging |
|---|---|---|---|
| 179 | 0.09% | 6000 counts | No |
| 28 II | 0.05% + 1 | 6000 counts | Min/Max only |
| 287 | 0.025% | 50,000 counts | Yes, graphical |
The 289 is a related logging model with industrial features; see its own page.
Information to send with an RFQ for 287
To prepare an accurate quotation, please send:
- Exact model 287 and the quantity required.
- Whether the meter is for a lab, a workshop or field service, so the correct accessory set can be quoted.
- Required test lead type and any extra clips or probes.
- Temperature probe, case or magnetic hanger requirements.
- Whether calibration traceability paperwork is needed on delivery.
- Delivery point in Oman or elsewhere in the GCC and the required date.
Storage, handling and spares for the Fluke 287
Store the Fluke 287 in its case or holster with the test leads disconnected. Remove the batteries if the meter will not be used for several weeks, because leaking cells can damage the battery contacts. In Oman and the GCC, do not leave the instrument in a parked vehicle during summer, where cabin temperature can go well above the storage limit in the user manual.
- Inspect test leads, probes and clamps before each use and replace any lead with damaged insulation or exposed metal.
- Use only leads and accessories rated for the same or a higher measurement category than the work you do.
- Keep spare fuses of the exact type given in the manual; a wrong fuse removes the protection the meter is built with.
- Plan a regular calibration interval, often twelve months, and keep the certificate with the instrument records.
If your team uses several units of the Fluke 287, it is useful to order spare test leads and batteries in the same RFQ, so that a meter is not taken out of service for a simple accessory.
Documents and quotation
A manufacturer datasheet for the Fluke 287 True-RMS Electronics Logging Multimeter is attached on this page so that you can check the full specification before ordering. Please review it against your site requirements.
For a quotation, send the part number 287, the quantity and your delivery location in Oman or the GCC through the RFQ button on this page. Availability and lead time are confirmed per request.
Datasheets & Documents
- Datasheet Fluke 287 Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Frequently requested Fluke models: Fluke 5522A Multi-Product Calibrator.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 287 True-RMS Electronics Logging Multimeter
Answers from our engineering team on installation, compatibility and integration.
01What is TrendCapture?
TrendCapture graphs logged readings on the meter screen so trends can be reviewed without a PC.
02How accurate is the Fluke 287 on DC voltage?
Basic DC voltage accuracy is 0.025% of reading, with a 1 µV resolution on the DC millivolt range.
03How much can it log?
The datasheet lists up to 10,000 logged readings, and the product page mentions up to 15,000 recorded events.
04Can it connect wirelessly?
Wireless use requires the optional Fluke ir3000 FC infrared connector.
05What batteries does it use?
Six AA alkaline cells, with at least 100 hours of use and 200 hours in logging mode.


















Reviews
There are no reviews yet.