Brand:

Megger MIT1025/2 10 kV Insulation Resistance Tester

Description

Overview

The Megger MIT1025/2 is the 10 kV model of the Megger Advanced range of insulation resistance testers. It is aimed at engineers and technicians who assess the condition of transformers, motors, generators, switchgear, bushings and cables, and who need more than a quick go or no-go reading. The Megger MIT1025/2 measures up to 20 TΩ, applies up to 10,000 V, and offers the full diagnostic suite used for predictive maintenance: insulation resistance, polarisation index, dielectric absorption ratio, dielectric discharge, step voltage, ramp and polarisation depolarisation current testing.

In Oman and across the GCC, insulation testing is a routine part of commissioning and outage work on power stations, grid substations, desalination plants, oil and gas facilities and large industrial motors. Seven Star LLC supplies the Megger MIT1025/2 from Muscat with engineering support, and we can discuss the correct test voltage, lead set and data-reporting workflow with your maintenance or commissioning team before you place an order.

Measurement Principle

The Megger MIT1025/2 applies a stabilised DC test voltage to the insulation under test and measures the resulting leakage current. Resistance is calculated from the ratio of the two values. Because insulation resistance changes with time, temperature and moisture, the instrument records not only the instantaneous value but also how the reading develops: the polarisation index compares readings at two points in time, and the dielectric absorption ratio compares shorter intervals. Both are widely used to judge whether insulation is dry, clean and healthy.

Two features of the Megger MIT1025/2 target the time and accuracy problems of field testing. PI Predictor uses the first part of the insulation resistance curve to predict the ten-minute result, so a polarisation index can be obtained in about five minutes, starting as early as three minutes into the test. The RE>Act test mode monitors reabsorption current so that residual charge in the insulation does not make a failing insulation look good, and it can also monitor discharge after the test so a dangerous return voltage does not remain on the equipment.

Engineering Design of the Megger MIT1025/2

The Megger MIT1025/2 uses a dual-case design: a tough outer case that protects against knocks and drops, and an inner fire-retardant case. With the lid closed the instrument is rated IP65, which keeps dust and moisture out during carrying and storage, and IP40 with the lid open. It is safety rated to CAT IV 600 V up to 3,000 m altitude and complies with IEC 61010-1, and five levels of voltage warning alert the user to live voltage above 30 V, to noise approaching or exceeding the instrument limit and to dangerous induced voltage.

The test current can be set at 1 mA, 3 mA or 6 mA, with 6 mA available from the mains supply, and the instrument tolerates up to 6 mA of interference current from 960 V to 10 kV, which allows measurements in energised substations up to 230 kV class environments. A rapid-charge 10.8 V, 5.2 Ah lithium-ion battery gives about 4.5 hours of continuous testing at 10 kV into a 100 MΩ load, and the tester can also run from a 90 to 264 V AC supply. Results are stored with time and date stamps and can be sent over USB or Bluetooth LE to PowerDB or CertSuite Asset.

Key Features

The Megger MIT1025/2 combines safety, accuracy and reporting in a single portable case:

  • Test voltages of 500 V, 1,000 V, 2,500 V, 5,000 V and 10,000 V plus a user-defined voltage, with a resistance range up to 20 TΩ at 10 kV.
  • Accuracy of plus or minus 5 percent up to 2 TΩ at 10 kV and up to 1 TΩ at 5 kV, as listed in the manufacturer datasheet.
  • PI Predictor shortens polarisation index tests, and the PDC mode supports advanced dielectric diagnostics when used with software.
  • RE>Act mode measures reabsorption current to avoid false passes and to check discharge after the test.
  • Selectable charge current of 1 mA, 3 mA or 6 mA and guard terminal performance that rejects surface leakage with a stated error of 1 percent or less.
  • Non-detachable insulated test clips on double-insulated silicone leads, supplied as a medium-clip and a large-clip 3 m lead set.
  • On-board memory storing about 5.5 hours of logging at 5 second intervals, with temperature and humidity values recorded.
  • Compatibility with CertSuite Asset and PowerDB for fast reporting without manual transcription.

Industrial Applications

Typical uses for the Megger MIT1025/2 include acceptance and maintenance tests on medium-voltage cables, switchgear, rotating machines and power transformers in utilities, oil and gas and industrial plants. In Oman, that covers the large motors that drive seawater pumps and compressors, the generators and transformers at power and desalination stations, and the medium-voltage feeders in Sohar and Duqm industrial areas. High ambient temperature and humidity make temperature and humidity recording useful when comparing results from different seasons.

Commissioning contractors benefit from the ability to benchmark new assets and then compare against the same test during later outages. Where a facility already owns multimeters and calibration tools such as the Fluke 87V industrial multimeter, or battery and standby-power systems that are tested with equipment like the Infratek 23DC-Source battery tester, the Megger MIT1025/2 completes the electrical test kit for insulation condition. Workshops that handle appliance and equipment safety checks may also review the Fluke 6500-2 portable appliance tester alongside it.

Technical Specifications

The specifications below come from the Megger datasheet for the Advanced range; MIT1025/2 values are listed where applicable.

Parameter Specification
Model Megger MIT1025/2 (Advanced range, 10 kV)
Test voltages 500 V, 1,000 V, 2,500 V, 5,000 V, 10,000 V and user defined
Resistance range 10 kΩ to 20 TΩ at 10 kV (digital display)
Accuracy Plus or minus 5 percent to 2 TΩ at 10 kV; plus or minus 20 percent to 20 TΩ
Short-circuit current 1 mA, 3 mA (default) or 6 mA (6 mA from mains only)
Test modes IR, IR(t), DAR, PI, SV, DD, PDC and ramp, with PI Predictor and RE>Act
Safety CAT IV 600 V to 3,000 m, IEC 61010-1
Ingress protection IP65 lid closed, IP40 lid open
Interfaces USB type B and Bluetooth LE
Weight and size 4.5 kg; 315 x 285 x 181 mm

Request a Quote for Megger MIT1025/2

Seven Star LLC can quote the Megger MIT1025/2 together with the lead sets and accessories your team needs. Send us the equipment you plan to test, the maximum voltage class and your reporting software, and we will confirm availability in Muscat, supply the official datasheet and arrange delivery across Oman and the GCC. Contact our instrumentation division to discuss the Megger MIT1025/2 and related electrical test equipment for your next outage or commissioning campaign.

Datasheets & Documents
  • PDF Datasheet Megger MIT525/2, MIT1025/2 and MIT1525/2 Advanced Insulation Resistance Testers Datasheet (Official) Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Megger is the British maker of electrical test instruments whose name became the everyday word for an insulation tester. Its roots go back to 1889, when Sydney Evershed built an early insulation testing set, and the Megger trademark was registered in 1903. The group is headquartered in Dover, UK.

Seven Star LLC is an independent supplier in Muscat. We list Megger insulation testers, low resistance ohmmeters, earth testers, cable fault locators and relay test sets for testing and maintenance teams in Oman and the GCC.

Megger company profile

Origins 1889 insulation testing set by Sydney Evershed. Evershed & Vignoles was formed in 1895, and the Megger trademark was registered in 1903.
Headquarters Dover, UK, with major US sites in Dallas (Texas) and Valley Forge (Pennsylvania)
History Evershed & Vignoles joined AVO in 1968, and the group took the Megger name in 2002
Product families Insulation resistance testers, low resistance ohmmeters, earth testers, cable fault location, relay and circuit breaker test sets, transformer and battery testers, multimeters and installation testers
Users Utilities, substation and switchgear contractors, oil and gas maintenance teams, motor and cable testing, building services electricians

Milestones

  • 1889: Sydney Evershed's insulation testing set.
  • 1895: Evershed & Vignoles is formed.
  • 1903: The Megger trademark is registered.
  • 1968: Evershed & Vignoles joins AVO.
  • 2002: The group takes the Megger name.

Megger instruments we list

Model Type Typical job
MIT1025/2 10 kV insulation resistance tester Insulation, polarisation index (PI) and dielectric absorption tests on MV cables, motors, generators and transformers
DLRO10X 10 A digital low resistance ohmmeter Micro-ohm tests on busbar joints, breaker contacts, cable splices and bonds
DET4T2 Four-terminal earth tester Earth electrode resistance and soil resistivity for substations and earthing systems
TDR2000/3 Dual-channel time domain reflectometer Locating faults, splices and opens on power and communication cables
SMRT410 Multi-phase relay test system Secondary injection testing of protection relays during commissioning and maintenance

An insulation test applies a DC voltage and measures the leakage current to give a resistance value. Tracking that value and the PI over time shows moisture and ageing in a winding or cable long before it fails. The test voltage is chosen from the equipment's rated voltage, so a 10 kV tester can test MV equipment properly where a 1 kV or 5 kV model cannot.

Where Megger instruments are used

In Oman and the GCC, Megger testers are standard equipment for substation commissioning, switchgear and cable acceptance tests, motor and generator maintenance in oil and gas, power and water plants, and periodic earthing system checks.

Ordering Megger instruments: what we need

Send the model and any kit or accessory codes (leads, carry case, software, calibration certificate), and say whether a UKAS or ISO 17025 calibration certificate is required. For relay test sets, list the number of current and voltage channels you need and the test software.

Facts checked against Megger company history pages, October 2026.

FAQ

Questions about the Megger MIT1025/2 10 kV Insulation Resistance Tester

Answers from our engineering team on installation, compatibility and integration.

01What is the Megger MIT1025/2 used for?
The Megger MIT1025/2 is a 10 kV insulation resistance tester for diagnostic testing of transformers, motors, generators, switchgear and cables. It supports IR, PI, DAR, DD, step voltage, ramp and PDC modes.
02What is PI Predictor on the Megger MIT1025/2?
PI Predictor uses the first part of the insulation resistance curve to predict the ten-minute result, so a polarisation index can be obtained in about five minutes. It can start as early as three minutes into the test.
03How accurate is the Megger MIT1025/2?
The datasheet lists plus or minus 5 percent accuracy up to 2 TΩ at 10 kV and up to 1 TΩ at 5 kV, with plus or minus 20 percent up to 20 TΩ at 10 kV. Always check that your expected readings sit within the accuracy range.
04Can the Megger MIT1025/2 store and export results?
Yes. It stores time-stamped results with temperature and humidity values and transfers them by USB or Bluetooth LE to PowerDB or CertSuite Asset for reporting.
05Does Seven Star LLC supply the Megger MIT1025/2 in Oman?
Seven Star LLC supplies the Megger MIT1025/2 from Muscat with engineering support for customers in Oman and the GCC. Send your test voltage and reporting requirements and we will prepare a quotation.