Fluke 289 True-RMS Industrial Logging Multimeter
Description
Fluke 289 True-RMS industrial logging multimeter
The Fluke 289 is a handheld digital multimeter with a 50,000-count display, true-RMS AC measurement and built-in data logging for industrial troubleshooting. It records readings over time and plots them on the screen as a trend, which makes intermittent faults visible without sitting beside the equipment. Seven Star LLC supplies the Fluke 289 in Oman and the GCC as an independent supplier in Muscat.
The model number 289 is the flagship of the 280 series; it adds logging, TrendCapture and a bigger memory over the basic meters, and works best for electricians and instrument technicians on drives, panels and process loops.
Fluke 289 technical specifications
| Parameter | Specification |
|---|---|
| Manufacturer / model | Fluke / 289 |
| DC voltage | 50 mV to 1000 V, 6 ranges; basic accuracy 0.025% |
| AC voltage (true-RMS) | 50 mV to 1000 V; basic accuracy 0.4%; 100 kHz bandwidth |
| DC current | 500 µA to 10 A; 0.05%; 20 A for 30 s |
| AC current (true-RMS) | 500 µA to 10 A; 0.6% |
| Resistance | 50 Ω to 500 MΩ; 0.05% |
| Capacitance | 1 nF to 100 mF; 1.0% |
| Frequency | 99.999 Hz to 999.99 kHz; 0.005% |
| Temperature | −200 to 1350 °C excluding probe; 1.0% |
| Display | 50,000 count dot-matrix with white backlight |
| Logging memory | Up to 15,000 readings; interval and event logging |
| Power | 6 AA alkaline; 100 h minimum, 200 h in logging mode |
| Operating temperature | −20 to 55 °C |
| Maximum voltage to earth | 1000 V |
| Size / weight | 22.2 × 10.2 × 6 cm / about 871 g |
How logging and TrendCapture work
The 289 can store readings at a set interval or only when a value changes outside a threshold. The data are shown on-screen as a graph that can be zoomed up to 14 times, so a drifting current or a voltage dip is seen at a glance. An internal real-time clock timestamps every entry, and the optical interface can pass the log to a PC. An optional wireless connector (ir3000 FC) is sold separately.
For a typical job, a technician clips the meter on a compressor starter or a 4–20 mA loop overnight and reviews the trace in the morning, rather than guessing at the time of failure.
Measurement features that matter on site
- LoZ volts mode loads the circuit lightly to remove ghost voltage readings on long cables.
- Selectable AC filter and low-pass filter give stable readings on variable frequency drive outputs.
- Min/max/average, duty cycle, pulse width and dBV/dBm functions.
- Transient capture as fast as 250 µs with peak capture.
- Two-terminal 50 Ω range with 1 mΩ resolution for low-resistance joints.
- On-board help screens for the less used functions.
Choosing the Fluke 289 and related models
The 289 is chosen when logging is actually needed. The similar 287 offers the same 50,000-count measurements with a smaller feature set, while the 87V suits plain maintenance work where logging is not required. When comparing, check memory size, trending and the display, not just the voltage ranges.
| Model | Position |
|---|---|
| 289 | Logging with TrendCapture, 15,000 readings |
| 287 | Related 280-series model with fewer logging functions |
| 87V | Compact industrial meter without logging |
Compare accessories (test leads, thermocouples, clamps) when confirming a model, because the meter ships as a basic package.
Use, safety and care
Always check that the test leads, input jacks and range suit the measurement and the voltage on the circuit. Read the rating on the meter and probes, because the product page quotes a 1000 V maximum to earth but does not give a category for the 289; confirm the category on the instrument label for your task. Keep fuses of the specified type, replace the six AA cells when the battery indicator appears and store the meter between −40 and 60 °C. Annual verification against a reference is a common practice for instruments used in quality-controlled work.
Typical applications in Oman and the GCC
Maintenance teams in power stations, desalination plants, refineries and large commercial buildings use a logging multimeter for drive and motor checks, control-loop fault finding and thermocouple measurements. In hot field conditions the meter’s operating range of up to 55 °C is important; avoid leaving it on a dashboard or in direct sun, and keep it in its case between jobs.
Information to send with an RFQ
- Model Fluke 289 and quantity
- Kit or body only; required probes, thermocouples or current clamps
- Wireless or PC logging requirement
- Calibration certificate requirement
- Delivery destination in Oman or the GCC
Accessories, calibration and spares for the Fluke 289
The Fluke 289 is normally bought with extra items: spare test leads and probes, a thermocouple bead probe for the temperature function, current clamps for higher currents than the 10 A input, and a carrying case. Ask for the accessories that suit your voltage and current work instead of assuming they come in the box. Spare fuses of the correct type and a set of AA batteries should be kept with the meter.
For inspected plants and contractors, a calibration certificate and periodic re-calibration are normal; tell us if you need a certificate with the 289 so that we can include it in the quotation. Check the battery contacts after long storage in hot vehicles, and clean the display and ports with a soft dry cloth.
Getting logged data off the Fluke 289
Logged sessions and saved readings can be transferred to a PC through the optical interface on the back of the meter, using the Fluke IR USB cable and FlukeView Forms software. The software turns a logging session into a table and graph that can be attached to a maintenance report or a commissioning record, which is useful when the same feeder or motor is checked again months later.
For quality systems, plan a calibration interval; Fluke states the 289 accuracy specifications for one year, so annual calibration with a traceable certificate is the usual practice. Check the test leads and fuses before each critical job, and keep the meter in its case when it is carried between hot outdoor sites and air-conditioned control rooms.
Related Fluke products: Fluke 87V Industrial Multimeter, Fluke 1587 FC Insulation Multimeter, Fluke 8508A Reference Multimeter, Fluke 117 Electrician', Fluke 376 FC True-RMS AC/DC Clamp Meter with iFlex and Fluke 62 MAX+ Infrared Laser Thermometer.
Documents and quotation
Send us the model 289 and the accessories you need and we will confirm the documents available for your quotation.
Seven Star LLC is an independent supplier and not an official representative of the brand.
Datasheets & Documents
- Datasheet Fluke 289 Technical Data Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Fluke is the American maker of handheld electronic test tools: digital multimeters, clamp meters, insulation testers, process calibrators, thermometers, vibration meters and power quality analysers. John Fluke founded the John Fluke Engineering Company in Springdale, Connecticut, in June 1948 and moved it to Seattle in 1952. Fluke is headquartered in Everett, Washington, was acquired by Danaher in 1998 and has been part of Fortive since Fortive's spin-off from Danaher in 2016.
Seven Star LLC lists Fluke process calibrators, electrical test tools and bench calibrators, and sources them for maintenance teams and calibration laboratories in Oman.
Fluke company profile
| Founded | June 1948, Springdale, Connecticut, USA, as the John Fluke Engineering Company |
|---|---|
| Founder | John M. Fluke Sr. |
| Headquarters | Everett, Washington, USA (moved to the Seattle area in 1952) |
| Ownership | Danaher from 1998; part of Fortive (NYSE: FTV) since July 2016 |
| Product families | Digital multimeters and clamp meters, insulation resistance testers, process and loop calibrators, infrared thermometers and thermal imagers, vibration meters, power quality analysers, Fluke Calibration laboratory standards |
Milestones
- 1948: John Fluke starts the company in Springdale, Connecticut.
- 1952: The company moves to Seattle
- 1987: A joint venture with Philips leads to the ScopeMeter handheld oscilloscope.
- 1998: Danaher acquires Fluke.
- 2016: Fluke becomes part of Fortive, spun off from Danaher in July.
Fluke calibrators and test tools listed
The main Fluke products on this page fall into three groups, besides other test tools such as further multimeters, a thermometer, an anemometer, a vibration tester and a portable appliance tester:
- Process tools: the 754 documenting process calibrator with HART, 789 ProcessMeter, 721 dual sensor pressure calibrator and 729 automatic pressure calibrator
- Electrical test: the 376 FC true-RMS clamp meter with iFlex probe and the 1587 FC insulation multimeter
- Fluke Calibration bench standards: 5522A, 5502A, 5500A and 5080A multi-product calibrators, the 5720A multifunction calibrator, 8508A reference multimeter, 6100A electrical power standard and 9640A RF reference source
Several of the bench models belong to earlier generations. When a model is no longer produced, we check the manufacturer's documentation and propose the successor it names.
Where Fluke instruments are used
Fluke process calibrators are used for loop checks, transmitter calibration and valve tests in oil and gas, power and water plants. Clamp meters and insulation testers serve electrical maintenance on motors, switchgear and cables. The bench calibrators and reference multimeters are the working standards of electrical calibration laboratories in the GCC, where they calibrate multimeters, clamp meters, process tools and power analyzers.
Fluke products we list
Ordering Fluke instruments: what we need
Send the exact model with its suffix, since versions differ. A Fluke 721, for example, is defined by its two pressure ranges, and a 729 by its maximum pressure. For bench calibrators, list the options you need, such as oscilloscope calibration or power quality options, the line voltage, and the type of calibration certificate you require from the manufacturer. For Fluke multimeters and clamp meters, add the kit contents wanted, such as probes, leads or cases.
Facts checked against published histories of Fluke Corporation and Fortive, October 2026.
Browse Fluke products by category: Portable Test & Measurement.
FAQ
Questions about the Fluke 289 True-RMS Industrial Logging Multimeter
Answers from our engineering team on installation, compatibility and integration.
01What display resolution does the Fluke 289 have?
It has a 50,000-count display with white backlight, and the DC volts range reaches 1 microvolt resolution.
02How much data can it log?
It stores up to 15,000 readings in interval or event mode, with TrendCapture graphing and zoom.
03What is the DC voltage accuracy?
Basic DC voltage accuracy is 0.025 percent, up to 1000 V.
04How is it powered?
Six AA alkaline cells, with at least 100 hours of use and about 200 hours in logging mode.
05Can it measure temperature?
Yes, from -200 to 1350 degrees C excluding the probe, with 1.0 percent accuracy.


















Reviews