Cortem FHL-124 Ex 24 W Portable Inspection Lamp
Description
Cortem FHL-124 overview
The Cortem FHL-124 is a handheld Ex inspection lamp from the Cortem FHL series, built for maintenance crews who must see inside tanks, pits, engine rooms and process areas where flammable gas or dust may be present. It takes one compact four-pin fluorescent tube (24 W) behind a polycarbonate tube and a 316L stainless steel guard, and it is supplied from a 24 V DC safety extra-low-voltage source with the electronic ballast sealed inside the handle.
Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. Technical statements on this page are summarised from the manufacturer catalogue sheet for the series, and the part number to quote is Cortem FHL-124.
Key features of FHL-124
- Integrated electronic ballast sealed with two-part resin in the handle
- Polycarbonate tube protected by an electro-polished 316L stainless steel guard
- Stainless steel hook for hanging; optional magnet, base for vertical use, eyebolt and reflector
- Certified for Zones 1, 2, 21 and 22 with IP66 enclosure
- 24 V DC supply reduces shock risk in confined spaces
FHL-124 technical specifications
| Parameter | Value |
|---|---|
| Series | FHL portable inspection lamp |
| Protection concept | Ex e mb IIC, Ex tb IIIC (II 2GD) |
| Zones | 1, 2, 21, 22 |
| ATEX certificate | CESI 09 ATEX 041X |
| Temperature class | T6 (85 degrees C) |
| Ambient temperature | -40 to +50 degrees C |
| Ingress protection | IP66 |
| Supply voltage | 24 V DC |
| Lamp holder | 2G11 (4-pin), compact fluorescent tube not included |
| Ballast | Electronic, in the handle |
| Cable entry | 1 x 1/2 inch NPT with NAV1NB cable gland for non-armoured cable |
| Guard | 316L stainless steel |
| Tube | Polycarbonate |
| Coating | Polyester RAL 7035 |
| Lamp | 1 x PL-L 24 W compact fluorescent (spare code LAMP-PLL24W) |
| Length A / A1 | 622 mm / 544 mm |
| Max. surface temperature | 79.1 degrees C |
| Weight | 1.30 kg |
| Part number | FHL-124 |
Values above are taken from the series catalogue. Confirm the marking and temperature class on the certificate for the exact version you order before commissioning FHL-124.
Typical applications in Oman and the GCC
Typical uses for FHL-124 include tank and vessel entry inspection, turnaround and shutdown maintenance in refineries and petrochemical units, offshore module work, ship engine rooms and grain or powder silos. In oil and gas facilities across Oman and the Gulf, explosion-protected lighting and power connection equipment is needed wherever flammable vapours, gases or combustible dust can collect. The same requirements appear in utilities and power stations with fuel handling, in water and wastewater plants where biogas or chemicals are present, and in manufacturing sites that process solvents, grain or powders.
High ambient temperatures, salt-laden coastal air and sand are common in the region, so check the rated ambient range and ingress protection of FHL-124 against the site conditions and the area classification drawings.
Hazardous area planning considerations
Explosion-protected equipment is chosen after the plant owner has completed an area classification that defines the zone, the gas or dust group and the maximum permitted surface temperature. The equipment must then carry a certificate and marking that cover each of these three points, and the temperature class must stay below the ignition temperature of the substances present. Documentation should be kept with the plant records so inspectors can match every installed item to its certificate.
Environmental factors also matter in Gulf installations. Strong sunlight, high humidity near the coast, windblown sand and washdown with fresh water all affect gaskets, coatings and entries over time. Specifying suitable cable glands, blanking elements and sealing fittings, and tightening them to the instructions, protects the ingress rating and the integrity of the protection concept throughout the service life of the installation.
Spare-parts planning is another practical point. Maintenance teams often keep a small stock of the most exposed parts, such as gaskets, lamps, plugs or companion items, so that a failure can be corrected without waiting for a new order. Quoting the exact code from the manufacturer catalogue avoids mistakes when similar variants differ only by power, voltage, length or current rating.
Selection and compatibility notes for FHL-124
Choose FHL-124 when a 24 W light output is adequate for the working distance; the other length in the series uses the 36 W tube. Confirm that your 24 V DC supply is taken from a safe area and rated for the lamp, and order the cable gland, plug and accessories you need separately because the lamp is supplied with a NAV1NB gland and the compact fluorescent tube is not included.
Always compare the zone, gas group and temperature class of FHL-124 with the hazardous area classification of the installation, and verify cable entries, glands and accessories separately because they are listed as distinct items by the manufacturer.
Installation and commissioning
Connect the supply to the L, N and PE terminals on the electronic board with conductors up to 2.5 mm2, using the supplied cable gland on the 1/2 inch NPT entry. Fit the correct four-pin compact fluorescent tube, close the lamp and check that the polycarbonate tube and silicone gaskets are seated. Do not open the lamp in a hazardous area while energised.
Installation of FHL-124 should follow the local hazardous area installation standard such as EN/IEC 60079-14 and the manufacturer instructions, and should be carried out by qualified personnel. Before energising, check enclosure integrity, earthing and the tightness of all entries.
Maintenance and inspection
Inspect the polycarbonate tube, guard, hook and gaskets for damage before every shift. Replace the tube only with the type named in the catalogue. Spare and accessory codes listed by the manufacturer for this lamp include LAMP-PLL24W, G24-669 reflector, G24-0558 ballast. The cable winder offered for the series may be used in safe areas only.
Keep a record of inspections for FHL-124 as part of the plant electrical inspection programme, and never modify a certified enclosure.
Related products and ordering notes
Other codes in the same series are available with different ratings, and related Ex junction boxes, cable glands, plugs and luminaires from the same manufacturer can be quoted together with FHL-124. When you order, state the exact code, quantity, supply voltage and the area classification so the offer matches the application.
FHL-124 FAQ summary
Buyers most often ask what FHL-124 is, which hazardous areas it suits, whether a datasheet is available, and how to request a quotation. The answers are listed in the FAQ on this page, and the independent supplier status of Seven Star LLC is stated above.
Documents and quotation
The manufacturer catalogue sheet for the series is attached to this page as the datasheet for FHL-124. To request a quotation, send the RFQ with the part number FHL-124 and the quantity required, together with the delivery location, and we will reply with availability and lead time.
Cortem FHL-124 vs Other Cortem Ex W Portable Inspection Lamp Variants
Pick this variant when FHL-124 24 is what your sizing calculation or the installed nameplate calls for. Neighbouring variants in the same family share the mounting concept and most accessories, so the difference that matters on site is exactly that rating.
| Variant | Distinguishing detail |
|---|---|
| Cortem FHL-124 Ex 24 W Portable Inspection Lamp (this page) | FHL-124 24 |
| Cortem FHL-136 Ex 36 W Portable Inspection Lamp | FHL-136 36 |
Other Models in the Fhl Range
Seven Star LLC supplies models from the Fhl range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Cortem FHL-124 Ex 24 W Portable Inspection Lamp | Industrial & Hazardous Area Lighting | You are viewing this model |
| Cortem FHL-136 Ex 36 W Portable Inspection Lamp | Industrial & Hazardous Area Lighting | View details |
Datasheets & Documents
- Datasheet Cortem FHL-124 Ex 24 W Portable Inspection Lamp Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Cortem is the Italian maker of explosion-proof and increased-safety electrical equipment: Ex d and Ex e lighting, enclosures, control stations, plugs and sockets, cable glands and signalling devices. Marco Rossi and Renato Gratton founded the company on 24 February 1968 in Villesse, in the Friuli Venezia Giulia region of north-east Italy. Cortem S.p.A. heads the Cortem Group, which also includes Elfit and the Fondisonzo foundry, and supplies onshore and offshore oil and gas, chemical and industrial plants.
Seven Star LLC is an independent supplier in Muscat. We list Cortem junction boxes, lighting, plugs and sockets and control stations for oil and gas and process projects in Oman and the GCC.
Cortem company profile
| Founded | 24 February 1968, Villesse (Gorizia), Italy |
|---|---|
| Founders | Marco Rossi and Renato Gratton |
| Name | From the Italian for electromechanical construction and technical representation |
| Group companies | Cortem S.p.A., Elfit and Fondisonzo |
| Approvals | ATEX and IECEx certified explosion-protected equipment |
| Product families | Ex d and Ex e luminaires and LED fittings, emergency and exit lights, obstruction lights, junction and control boxes, control stations, plugs and sockets, cable glands, alarm and signalling devices |
Milestones
- 1968: Marco Rossi and Renato Gratton found Cortem in Villesse on 24 February.
- 2011: Research and development on LED lighting for hazardous areas begins.
- 2012: The first Cortem LED fixture series is launched.
- 2022: The third generation of Cortem LED fixtures is released.
Cortem product series
Enclosures include the EJBX stainless steel Ex d junction boxes, EJBC aluminium Ex d boxes for gas group IIC, the SA and SAG Ex eb aluminium boxes in 18 sizes and the EJBE and EJBXE Ex de control and distribution boards. Control and power connection products include the CMD Ex e fibreglass control stations and the PYN, SPYN and CMBSP07 Ex plugs and sockets from 16 to 125 A.
Lighting covers the SLED-ME and EVL-40 Ex LED floodlights, the Ex nR SLED-MN and EVNL-40 floodlights for zone 2, the LIFEX-M linear fixture, the FLOWEX high bay, the EVML low bay, STREETEX street lighting and the XLFE-LIB and XLFE-MIA obstruction lights for stacks and towers. The GRDE-4200 is an electronic earthing system for road tanker loading bays.
Where Cortem equipment is used
Refineries, gas plants, tank farms and loading terminals, offshore platforms and ships, chemical and pharmaceutical plants and mining. Products are certified to ATEX and IECEx, with other schemes according to model.
Cortem products we list
Ordering Cortem products: what we need
Send the model code, the zone and gas or dust group, temperature class, ingress protection, the certification scheme required, and for enclosures the size, entries and internal components. For lighting give the wattage, voltage and mounting; for plugs and sockets the current, poles and voltage.
Facts checked against Cortem Group's published company history, October 2026.
Browse Cortem products by category: Automation Accessories.
FAQ
Questions about the Cortem FHL-124 Ex 24 W Portable Inspection Lamp
Answers from our engineering team on installation, compatibility and integration.
01What is Cortem FHL-124?
FHL-124 is a Cortem 24 W 24 V DC portable Ex inspection lamp from the manufacturer catalogue series, designed for use in hazardous areas as stated on its certificate.
02Which hazardous areas is FHL-124 suitable for?
The zones, gas or dust groups and temperature class for FHL-124 are listed in the specification table on this page and on the series certificate, which must be checked before installation.
03Is a datasheet available for FHL-124?
Yes. The manufacturer catalogue sheet for the series is attached to this page and contains the dimensions, certification data and code table relevant to FHL-124.
04Does Seven Star LLC manufacture Cortem FHL-124?
No. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
05How do I request a quote for FHL-124?
Send the RFQ with the part number FHL-124, the quantity, the area classification and the delivery location, and we will reply with availability and lead time.