Brand:

Bronkhorst M14 mini CORI-FLOW Coriolis Mass Flow Meter 30 kg/h

Description

Overview

Bronkhorst M14 is the largest of the three standard mini CORI-FLOW Coriolis meters and measures liquids up to 30 kg/h and gases up to 400 ln/min of nitrogen. It keeps the compact stainless steel housing of the smaller models, yet moves into flow rates that suit pilot plants, test benches and dosing skids. Seven Star LLC is an independent supplier serving Oman and the GCC.

Bronkhorst M14 at a glance

  • Liquid range 0 to 30 kg/h; nominal flow rate 10 kg/h; full scale user-configurable from 1 to 30 kg/h.
  • Gas range 0 to 400 ln/min (N2).
  • Accuracy ±0.2 % Rd for liquids and ±0.5 % Rd for gases; density ±5 kg/m3.
  • Turndown up to 1:1000, zero point stability ±6.0 g/h.
  • Single-tube sensor with DN 1.3 inner diameter.
  • 200 barg pressure rating, IP65 housing, 1.1 kg.

Specification table for the M14

Specification Entry in datasheet
Response time 200 msec or less
Repeatability ±0.05 % Rd ± ½ (ZS x 100 / actual flow) %
Temperature sensitivity Zero 0.5 g/h per °C; span 0.001 % Rd per °C; self heating below 15 °C
Operating and fluid temperature 0 to 70 °C; ATEX Category 3 Zone 2 up to 50 °C fluid
Leak integrity Below 2 x 10-9 mbar l/s He
Mounting Any position
Warm-up 30 minutes
Wetted parts Stainless steel 316L or Hastelloy C22; metal-only seals
Supply 15 to 24 Vdc ±10 %, 2.5 W typical
Marking CE, UKCA, RoHS, WEEE, REACH

What sets the M14 apart

A larger tube changes the character of the instrument. With DN 1.3 the pressure drop at full flow is lower than in the small-bore models, the zero point stability value moves to ±6.0 g/h, and the turndown is 1:1000 rather than 1:2000. In practical terms the M14 is the model for flows where a few grams an hour no longer matter, such as 5 to 30 kg/h of fuel, solvent or water-based fluids. The temperature coefficient on zero is 0.5 g/h per °C, compared with 0.02 g/h per °C on the M13 and 0.01 g/h per °C on the M12, which tells you the zero reading matters less at this range.

How Bronkhorst M14 differs from other mini CORI-FLOW variants

M12: 0 to 200 g/h, DN 0.25. M13: 0 to 2 kg/h, DN 0.5. M14: 0 to 30 kg/h, DN 1.3. The housing, 200 barg rating, IP65 protection and 1.1 kg weight are shared. Only the M14 can pass the 400 ln/min of nitrogen listed for gas service, making it the only one of the three for larger gas streams. If your process needs more than 30 kg/h, ask for a larger Coriolis model.

Electrical connection and communication

RS232 is standard; options are DeviceNet, PROFIBUS DP, Modbus RTU and FLOW-BUS. Analog outputs are 0 to 5 (10) Vdc or 0 (4) to 20 mA, and the analog setpoint is accepted in the same ranges. Connectors: 8-pin DIN (male) for power, analog and RS232 on the instrument connector, 4-pin M8 (female) for the actuator output, 5-pin M12 B (female) for PROFIBUS DP and 5-pin M12A (male) for CANopen, DeviceNet, Modbus RTU, ASCII and FLOW-BUS. The actuator output lets the instrument drive an external control valve, which turns the meter into a control loop.

Typical use in Oman and the GCC

At up to 30 kg/h the Bronkhorst M14 suits fuel flow measurement on engine and burner test rigs, solvent and chemical feed at petrochemical pilot plants, cooling-fluid circuits on test benches, and checking the delivery of dosing pumps at water treatment plants. In process laboratories at refineries it can be used to check sample or reflux streams with direct mass measurement, which avoids density corrections when temperature varies between day and night in hot climates.

Installation notes

Any mounting position is permitted. Make sure the sensor is fully filled, avoid air pockets, zero with the line closed and full, and decouple vibration. Connect with compression, VCR/VCO or welded Tri-Clamp fittings as ordered. The unit is supplied without hazardous area approval by default; ATEX Zone 2 and KCs are optional.

Service

Flush after use, observe the 200 barg limit and keep operating and fluid temperatures within 0 to 70 °C. Return the meter for recalibration at the interval your quality plan requires.

Ordering the Bronkhorst M14

When you request a quotation for the Bronkhorst M14, specify the fluid, whether the flow is liquid or gas, the full scale between 1 and 30 kg/h, the maximum pressure up to 200 barg, the fluid temperature and the connection type. If you will measure gas, give the gas and the pressure, since 400 ln/min is quoted for nitrogen. State the interface for the control system and whether an optional hazardous area certification, ATEX Zone 2 or KCs, is required.

Sizing hints

Choose the model so that your normal flow lies in the middle of the range. With a nominal flow of 10 kg/h, the M14 reads best between roughly 3 and 25 kg/h; a process that runs below about 2 kg/h is better served by the M13. Because the full scale is user-configurable down to 1 kg/h, you can range the instrument for the present process and widen the range later without replacing hardware. Include a strainer ahead of the inlet to protect the DN 1.3 tube from debris, and support the pipework close to the meter so that plant vibration does not couple into the sensor.

Maintenance and cleaning of the M14

The wider DN 1.3 tube is less sensitive to small particles, but a strainer before the inlet is still good practice. When the fluid is changed, flush the meter fully, then zero it with the line closed and full. Because pressure can reach 200 barg, depressurise the line before loosening any fitting, and re-check tightness with a gas leak test after reassembly. The housing is IP65, which resists dust and water jets, though the connectors should be fitted with their mating plugs. Keep a log of the zero value so you can plan recalibration before the drift becomes significant.

Related items you may also need: Micro Motion R-Series General Purpose Coriolis Flow and Density Meters | KROHNE OPTIMASS 2400 High-Capacity Coriolis Mass Flowmeter | Rheonik RHM06 Coriolis Mass Flow Meter Sensor 36 kg/min | All Bronkhorst products.

Documents and quotation

The datasheet for the Bronkhorst M14 is supplied as a PDF with this listing. To request a quotation, send the part number M14, fluid, flow range, connection, interface option and quantity to Seven Star LLC for Oman and the GCC.

Datasheets & Documents
  • PDF Datasheet Bronkhorst M14 mini CORI-FLOW Coriolis Mass Flow Meter 30 kg/h Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Bronkhorst is a Dutch maker of instruments for measuring and controlling small flows of gases and liquids, known as "the low-flow specialists". The company was founded in 1981 in Vorden, the Netherlands, and moved to Ruurlo in 1983, where its headquarters and campus are today. From thermal mass flow meters and controllers to Coriolis meters, its instruments are used in laboratories, analytical equipment, semiconductor and chemical process plants, and the company reports more than one million instruments in the field.

Bronkhorst company profile

Founded 1981, Vorden, the Netherlands
Headquarters Ruurlo, the Netherlands
Size More than 800 employees worldwide, about 600 of them at the headquarters; four production locations in Europe, Asia and America
Core technology Thermal mass flow meters and controllers for gases, Coriolis mass flow meters for liquids and gases, ultrasonic flow meters, plus pressure and vapor flow instruments
Typical applications Analytical instruments, gas blending, laboratory and pilot plants, chemical and energy transition processes, semiconductor and food and beverage production
Standards ISO 9001 certified since 1992; CE, RoHS, REACH marking on the instruments listed here; optional ATEX Zone 2 on mini CORI-FLOW meters

Milestones

  • 1981: Bronkhorst is founded in Vorden, the Netherlands.
  • 1987: The company is recognised with the King Willem I Plaque as the most innovative young company.
  • 1992: ISO 9001 certification is achieved.
  • 1997: M+W Instruments GmbH is acquired and becomes Bronkhorst Instruments in Germany.
  • 2005: Bronkhorst USA becomes the first subsidiary outside Europe.
  • 2019: An R&D office for MEMS sensors opens at the Technology Park in Enschede.

How a Bronkhorst thermal mass flow controller works

A thermal mass flow instrument sends a small part of the gas through a sensor tube that is heated. The flowing gas carries heat downstream, and the resulting temperature difference along the tube is proportional to the mass flow of the gas, so the reading does not depend on the line pressure or temperature the way a volumetric reading would. In a controller such as the EL-FLOW Select F-201CV, the measured value is compared with the setpoint and a proportional valve in the same block opens or closes until the two agree, typically within one to two seconds. Coriolis meters, such as the mini CORI-FLOW M12, M13 and M14, work differently: a vibrating tube is twisted by the mass moving through it, which allows direct mass and density measurement of liquids and gases. When selecting, match the principle to the fluid: thermal for clean, dry gases, Coriolis for liquids or mixed fluids.

Where Bronkhorst products are used in Oman and the GCC

Bronkhorst instruments suit laboratories and pilot plants at refineries, petrochemical sites, universities and water treatment utilities: calibration gas blending for gas detectors, carrier gas for analyzers, chemical dosing trials, fuel and reagent flow on test benches, and gas supply to process development rigs across the region.

Bronkhorst models we list

Family Examples
EL-FLOW Select thermal gas flow meters and controllers F-201CV, F-111B, F-201AV
EL-FLOW Prestige high performance gas controllers FG-201CV
mini CORI-FLOW low flow Coriolis meters M12, M13, M14

Ordering Bronkhorst products: what we need

Seven Star LLC is an independent supplier serving Oman and the GCC. For a quotation send the exact model code, the fluid or gas, the full-scale flow, the working pressure and temperature, the process connection and the interface needed, such as analog, RS232 or a fieldbus. Instruments are calibrated to the process data, so complete details avoid a wrong build; for spares or replacements, add the serial number from the nameplate.

Facts checked against the Bronkhorst company website and published Bronkhorst datasheets, November 2026.

FAQ

Questions about the Bronkhorst M14 mini CORI-FLOW Coriolis Mass Flow

Answers from our engineering team on installation, compatibility and integration.

01What flow does the Bronkhorst M14 measure?
Liquids up to 30 kg/h and gases up to 400 ln/min of nitrogen. The nominal flow is 10 kg/h and full scale is configurable between 1 and 30 kg/h.
02What is the sensor size of the M14?
The M14 uses a single-tube sensor with a DN 1.3 inner diameter, larger than the DN 0.25 of the M12 and the DN 0.5 of the M13.
03What accuracy and turndown does the M14 offer?
Accuracy is ±0.2 % of reading for liquids and ±0.5 % for gases, with turndown up to 1:1000 and zero point stability of ±6.0 g/h.
04What are the pressure and protection ratings of the M14?
The pressure rating is 200 barg and the housing is IP65, built from stainless steel 430F with wetted parts of 316L or Hastelloy C22.
05Which digital interfaces are offered for the M14?
RS232 is standard. Options are DeviceNet, PROFIBUS DP, Modbus RTU and FLOW-BUS, plus analog 0 to 5 (10) Vdc or 0 (4) to 20 mA signals.