Brand:

Micro Motion CMF025M ELITE Coriolis Flow Sensor DN6

Description

Overview

The Micro Motion CMF025M is the quarter-inch (DN6) 316L stainless steel member of the ELITE Coriolis sensor range from Micro Motion, built for low flow rates where a very small tube still has to deliver mass flow, density and temperature in one device. Its datasheet lists a nominal flow of 48.0 lb/min (1,310 kg/h) and a maximum of 79.9 lb/min (2,180 kg/h), which makes it a natural choice for chemical injection, additive blending, sample loops, skid-mounted metering and small custody-style transfers. Seven Star LLC is an independent supplier serving Oman and the GCC.

The trailing letter in the base code tells you the wetted material: M stands for 316L stainless steel, L for 304L and H for nickel alloy C22. Choosing M gives the corrosion resistance most hydrocarbon and utility duties need without moving to an exotic alloy.

What the Micro Motion CMF025M measures

A Coriolis sensor does not infer flow from velocity. The U-shaped tube is driven at resonance, and the mass moving through it twists the tube by an amount proportional to mass flow. The same vibration frequency reveals density, and an embedded temperature element reports process temperature. That is why one Micro Motion CMF025M replaces a flowmeter, a densitometer and a temperature probe on a skid.

  • Mass flow, volume flow and density from a single wetted path
  • Drive frequency class low (100 to 150 Hz) for CMF025, which the datasheet rates as preferred for two-phase installations
  • Smart Meter Verification for on-demand or scheduled health checks in under 90 seconds
  • Calibration performed in ISO/IEC 17025 facilities with uncertainty down to plus or minus 0.014 percent

Technical specifications of Micro Motion CMF025M

Parameter Value from the datasheet
Nominal line size 0.25 in (DN6)
Nominal flow rate 48.0 lb/min (1,310 kg/h)
Maximum flow rate 79.9 lb/min (2,180 kg/h)
Liquid mass and volume flow accuracy plus or minus 0.05 percent of rate (premium) or 0.10 percent (standard)
Flow repeatability 0.025 percent (premium) or 0.05 percent (standard)
Density accuracy plus or minus 0.2 kg/m3 (premium) or 0.5 kg/m3 (standard)
Gas mass flow accuracy plus or minus 0.25 percent of rate
Zero stability 0.001 lb/min (0.027 kg/h)
Maximum process pressure rating 1,500 psig (103.42 barg)
Case maximum pressure 850 psig (58.61 barg)
Typical case burst pressure 5,480 psig (377.83 barg)
Process temperature range minus 148 to 400 degrees F (minus 100 to 204 degrees C) for standard CMF models
Electronics ambient limits minus 40 to 140 degrees F (minus 40 to 60 degrees C)
Sensor weight 9 lb (4 kg)
Wetted material 316/316L stainless steel

How the Micro Motion CMF025M differs from other CMF variants

Neighbouring sizes in the same family shift the numbers in a predictable way. The CMF010M handles only 3.43 lb/min nominal and is rated to 1,812 psig, so it suits micro-dosing. The CMF050M raises nominal flow to 151 lb/min (4,121 kg/h) and weighs 14 lb (6 kg), while the CMF100M reaches 602 lb/min (16,372 kg/h) and 31 lb (14 kg). Against those, the Micro Motion CMF025M sits in the middle of the small-bore group: 48.0 lb/min nominal, 9 lb, and the same 1,500 psig process rating as the CMF050M. Its zero stability of 0.001 lb/min is far tighter than the CMF050M at 0.0029 lb/min, which matters when you run near the bottom of the range.

Choose the L version for 304L wetted parts, or the H version if the fluid is aggressive: the CMF025H raises the pressure rating to 2,755 psig (189.95 barg) but its zero stability is quoted as 0.0009 lb/min.

Typical applications in Oman and the GCC

In upstream oil and gas, a Micro Motion CMF025M on a chemical injection skid verifies inhibitor, methanol or glycol dosing by true mass rather than by pump stroke counts. Refineries and petrochemical plants use the size for catalyst, additive and odorant lines. Utilities apply it to fuel oil and chemical dosing for boilers and water treatment, and desalination plants use it where concentrated chemicals must be metered accurately. Manufacturers in food, beverage and pharmaceutical sectors choose small Coriolis meters for ingredient batching because the stainless steel body is easy to flush.

Selection and compatibility notes

A sensor needs a transmitter or a core processor option. The datasheet lists electronics interface codes, conduit options and approval codes that decide how the sensor is wired and which hazardous area class it meets. Available approvals across the series include CSA Class I Division 1 and Division 2, ATEX Zone 1 intrinsically safe Ex ib IIB/IIC, and IECEx. Process connections for the CMF025M include EN 1092-1 DN15 and DN25 weld neck flanges (codes 172, 176, 177, 178 and 183), DIN 2635 and DIN 2637 flanges (codes 300 to 303), plus ASME B16.5 Class 150 types. Because a 0.25 in tube is narrow, confirm that the fluid is free of solids and that the filtration upstream matches the viscosity and cleanliness of the product.

Always confirm the complete model code on the nameplate or in the quotation, since the letters after CMF025M specify connection, electronics, approval and calibration options such as the 0.05 percent or 0.10 percent mass flow calibration choices.

Installation and commissioning

Mount the Micro Motion CMF025M so the tube remains full and, for liquids, so the case drains. Support the pipework rather than the sensor, and avoid placing it beside strong vibration sources such as reciprocating pumps without isolation. Dimensional drawings for the CMF025M with ASME B16.5 Class 150 flanges give a length of 10 in (254 mm) overall, with other dimensions listed from A to E in the datasheet. After powering up, perform a zero with the line full and flow stopped; the intelligent design reduces the need for field re-zeroing. Keep electronics within minus 40 to 140 degrees F and use remote mounting when hot process lines would exceed that limit.

Maintenance and verification

With no moving parts in the flow path, routine maintenance is mostly verification. Smart Meter Verification compares the tube stiffness against factory values and records a pass or fail result that you can keep for audits. Inspect cable glands and conduit entries for moisture, keep a record of drive gain, and look at density trends to detect coating or build-up. Flush the tube with a compatible solvent when changing products.

Related products and ordering notes

Matching transmitters, mounting kits and cables are sold separately. When you request the Micro Motion CMF025M, tell us the fluid, flow range, process pressure and temperature, hazardous area classification and required output protocol so the full code can be matched to the datasheet tables. Smaller or larger neighbours such as the CMF010M, CMF050M and CMF100M can be quoted alongside.

Related items you may also need: Micro Motion T-Series Straight Tube Coriolis Flow and Density Meters | Micro Motion FVM Fork Viscosity Meter | Micro Motion F-Series Coriolis Flow and Density Meters | All Micro Motion products.

Documents and quotation

The product data sheet for the Micro Motion CMF025M family is attached to this page and covers performance, ratings, dimensions and the order code tables. To obtain a quotation, send the RFQ with the part number Micro Motion CMF025M, the required quantity, the full code if you already have it, and your delivery location in Oman or the wider GCC.

Datasheets & Documents
  • PDF Datasheet Micro Motion CMF025M ELITE Coriolis Flow Sensor DN6 Datasheet Download
Reviews (0)

Reviews

There are no reviews yet.

How would you rate this product?

It takes about 10 seconds — just tap a star. Your email is never published.

About brand

Micro Motion is the Emerson brand for Coriolis flow and density measurement. The company started in Boulder, Colorado, and made the Coriolis effect commercially practical for industrial mass flow metering from 1977. Emerson acquired Micro Motion in 1984, and the meters are still developed and built under the Micro Motion name.

Seven Star LLC, an independent supplier in Oman, lists the Micro Motion ELITE CMF400 Coriolis flow and density meter and the compact G-Series, and sources Micro Motion flow meters by complete model code.

Micro Motion company profile

Founded Boulder, Colorado, USA; Coriolis meters since 1977
Ownership Emerson since 1984
Technology Coriolis mass flow, with density and temperature measured from the same vibrating tubes
Product families ELITE (CMF), F-Series, H-Series, R-Series and T-Series Coriolis sensors; 1700, 2700, 4200 and 5700 transmitters; fork and tube density and viscosity meters

Milestones

  • 1977: Micro Motion begins selling Coriolis flowmeters from Boulder, Colorado.
  • 1984: Emerson acquires Micro Motion.

Micro Motion meter families

ELITE is the manufacturer's top performance family for flow and density, and the CMF400 is one of its larger line sizes. The G-Series is a newer, very compact family for general duty. Each sensor is paired with a Coriolis transmitter, and the range also includes density and viscosity meters. Liquids, gases and slurries can all be measured, which is why these meters appear in oil and gas, refining, chemical, food and marine service.

Micro Motion products we list

Family Examples
Flowmeters 4200 2-Wire Coriolis Transmitter, 4700 Configurable I/O Coriolis Transmitter, CDM100 Compact Density Meter CDM100P and…, ELITE CMF400 Coriolis Flow and Density M…, F-Series Coriolis Flow and Density Meters, FDM Fork Density Meter, FVM Fork Viscosity Meter, GDM Gas Density Meter and 6 more

Ordering Micro Motion meters: what we need

A Micro Motion sensor and its transmitter each have their own model code and serial number; send both. For a new meter we need the fluid, flow range, density, viscosity, operating pressure and temperature, line size, process connection and rating, wetted material, hazardous area approval, outputs and protocol. Custody transfer duty in the GCC should be stated up front because it changes the approvals and calibration options requested.

Facts checked against Emerson and Control Global histories of Coriolis metering, October 2026.

FAQ

Questions about the Micro Motion CMF025M ELITE Coriolis Flow Sensor DN6

Answers from our engineering team on installation, compatibility and integration.

01What flow range does the Micro Motion CMF025M cover?
The datasheet lists a nominal flow of 48.0 lb/min (1,310 kg/h) and a maximum flow of 79.9 lb/min (2,180 kg/h) for the 0.25 inch (DN6) CMF025M/L.
02What does the M stand for in Micro Motion CMF025M?
The last letter of the base code identifies the wetted material. M means 316L stainless steel, L means 304L stainless steel and H means nickel alloy C22.
03What accuracy can the CMF025M achieve on liquids?
With the premium calibration option the mass and volume flow accuracy is plus or minus 0.05 percent of rate, and the standard option is 0.10 percent; density accuracy is 0.2 or 0.5 kg/m3.
04Does the CMF025M need a separate transmitter?
It is a sensor and is combined with a transmitter or electronics interface chosen in the order code, so please provide your output and approval needs when requesting a quotation.
05What is the pressure rating of the CMF025M?
The datasheet gives 1,500 psig (103.42 barg) for the CMF025M process rating, with a case maximum of 850 psig (58.61 barg) and typical burst of 5,480 psig.