Brand: AMETEK
AMETEK 700-0002-024 Drexelbrook 3/4 in PTFE High-Temp Probe
Description
Why buyers search for AMETEK 700-0002-024
When a Drexelbrook level system sits on a hot, clean liquid, the rod that goes in the vessel is usually not the 3/8 inch general purpose element but something stouter. AMETEK 700-0002-024 is that stouter element: a 3/4 inch outside diameter PTFE insulated rod, described in the manufacturer table for high temperature non-coating liquids, interface and low viscosity service. It carries SE code 311 and is among the thickest rods the Universal IV selection table lists as a commonly used standard.
The headline number for 700-0002-024 is 450 F at 500 psi, with the table also quoting 1000 psi at 100 F. That is 150 F more temperature capability than the 3/8 inch PTFE rod 700-0001-022 achieves at the same 500 psi, and it is the reason 700-0002-024 is picked for hot condensate, thermal oil circuits at low pressure, and heated chemical day tanks.
700-0002-024 data at a glance
| Parameter | Value |
|---|---|
| Part number | 700-0002-024 |
| Sensing element type | RF admittance / capacitance rod probe |
| Construction | 3/4 inch OD PTFE insulated rod |
| Typical application | High temperature, non-coating liquid, interface, low viscosity |
| Maximum pressure at 100 F | 1000 psi |
| Maximum pressure at 450 F | 500 psi |
| Maximum temperature in table | 450 F |
| Universal IV SE code | 311 |
| Compatible electronics | Universal IV, Universal III, Universal Lite, RCT |
| Universal IV ambient range | -40 C to 75 C |
| Remote cable limit | 100 ft maximum |
| Supply and output | 13 to 30 VDC loop powered, 4-20 mA with HART |
| Process connections available | NPT, BSP, ANSI, DIN, JIS, Tri-Clamp, Grayloc |
Figures are taken from the Drexelbrook Universal IV Pro and Lite datasheet. Length and connection depend on the order.
Reading the pressure and temperature pair
The table gives two points for 700-0002-024, not one. At or below 100 F the element holds 1000 psi. As the process warms the allowable pressure falls, and at 450 F the manufacturer states 500 psi. Treat these as two corners of a derating line rather than as independent limits: you cannot pair 450 F with 1000 psi. Plant engineers in hot services should also remember the transmitter ambient limit of minus 40 to 75 C for the Universal IV electronics, which may call for a remote mounting configuration where the head would otherwise sit above a hot nozzle.
Typical applications for 700-0002-024 in the Gulf
Three installations account for most demand. In power and desalination plants, hot condensate and deaerator-adjacent drains are conductive, clean and warm, which is the zone where PTFE insulation earns its keep. In refineries, the manufacturer notes interface measurement as an intended use; the thicker 3/4 inch insulation gives a more stable capacitance step between water and hydrocarbon layers. In chemical blending, heated tanks of non-coating liquids are common, and an RF rod avoids the float and mechanical wear issues of older instruments.
How 700-0002-024 differs from other Drexelbrook variants
- Against 700-0001-022: diameter 3/4 inch versus 3/8 inch, and temperature to 450 F versus 300 F at 500 psi.
- Against 700-0002-027: 700-0002-024 is PTFE and non-coating; 027 is a 1/2 inch FEP rod for heavier coating conductive liquids, limited to 300 F.
- Against 700-0002-224: both are 3/4 inch PTFE rods reaching 450 F, but 224 is a remote-only element for electrostatic desalters.
- Against 700-0002-037: PVDF, 250 F and suited to slurries.
Installation notes for 700-0002-024
A 3/4 inch rod is rigid and heavier, so support the electronics head and consider side loading if the tank is agitated. Allow overhead clearance to insert the rod in one piece, or specify the length so it fits through the nozzle. Where process temperature exceeds the electronics ambient rating, mount remotely; the Universal IV allows up to 100 ft of cable between sensor housing and electronics. After mounting, run the empty and full calibration with the LCD keypad, and note that Cote-Shield coating rejection is not needed on a non-coating liquid.
Maintenance considerations
PTFE does not wet readily, so the surface stays clean in most services, but thermal cycling from ambient to 450 F can stress seals at the process fitting. Inspect the seal region at shutdowns. If the electronics are replaced during a modernisation, 700-0002-024 can remain in place because the manufacturer states it is common to Universal IV, III, Lite and RCT systems.
Ordering context
Provide insertion length, flange or NPT size, and whether the electronics are integral or remote. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer. We quote 700-0002-024 as a spare or as part of a new assembly depending on what you need.
Engineering checklist before you commit to 700-0002-024
Walk through a short checklist with the process engineer. Confirm the liquid is clean and non-coating, because a 3/4 inch PTFE rod will not reject heavy deposits the way a Pro model with Cote-Shield and a coating-service element does. Confirm the operating pair of temperature and pressure falls under the 450 F and 500 psi corner. Decide whether the 6 inch cooling extension mentioned in other Drexelbrook datasheets for temperatures above 300 F is needed on your assembly, and confirm the nozzle can pass a 3/4 inch rod. Finally confirm the electronics family and cable length if the head is to be mounted remotely. Writing down these answers before requesting a quotation for 700-0002-024 prevents most ordering mistakes and saves a second round of clarification.
For interface work, remember that the device reads the change in capacitance as the rod passes from one fluid to another. A thicker insulation layer lowers the absolute capacitance but gives a repeatable step, which is why 700-0002-024 is quoted for interface in the table. Calibrate at both fluid levels on site rather than relying on theoretical dielectric values.
Documents and quotation
The Universal IV datasheet listing 700-0002-024 is attached. Send your RFQ with part number 700-0002-024, quantity and the length and connection you need; availability and lead time will be confirmed in our reply.
Other Models in the Drexelbrook Rf Probes Range
Seven Star LLC supplies models from the Drexelbrook Rf Probes range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| AMETEK 700-0001-022 Drexelbrook 3/8 in PTFE Level Probe | Level Controllers | View details |
| AMETEK 700-0005-054 Drexelbrook PFA Thin Cable Probe | Level Controllers | View details |
| AMETEK 700-1202-001 Drexelbrook 316L PEEK Rod Probe | Level Controllers | View details |
| AMETEK 700-0002-024 Drexelbrook 3/4 in PTFE High-Temp Probe | Level Controllers | You are viewing this model |
| AMETEK 700-0005-018 Drexelbrook PVDF Flex Cable Probe | Level Controllers | View details |
Datasheets & Documents
- Datasheet AMETEK 700-0002-024 Drexelbrook 3/4 in PTFE High-Temp Probe Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
AMETEK is the American maker of electronic instruments and electromechanical devices, headquartered in Berwyn, Pennsylvania. It was founded in 1930 as American Machine and Metals. In process industries it is known through brands such as Western Research (sulfur recovery and H2S analysers), Thermox (oxygen analysers), Land (pyrometers), Drexelbrook (RF level) and Chandler Engineering.
Seven Star LLC is an independent supplier in Muscat. We list AMETEK process analysers, pyrometers, portable testers and spare parts, and supply them to gas plants, refineries and power stations in Oman and the GCC.
AMETEK company profile
| Established | 1930, USA, as American Machine and Metals; later renamed AMETEK |
|---|---|
| Headquarters | Berwyn, Pennsylvania |
| Structure | Two groups: Electronic Instruments (EIG) and Electromechanical (EMG) |
| Process brands | Western Research, Thermox, Land, Drexelbrook, Chandler Engineering, Ranarex |
Milestones
- 1930: American Machine and Metals is formed in March and listed on the New York Stock Exchange as AME.
- Early 1960s: The company is renamed AMETEK.
- 2021: AMETEK acquires Magnetrol.
AMETEK products we list
| Product | Type | Typical use |
|---|---|---|
| 888, 900, 930 | Western Research sulfur recovery analysers | Tail gas, air demand and H2S in sulfur pits on Claus units |
| 931, 933, 9900RM/WM | UV gas analysers | H2S in natural gas and multi-component process streams |
| 5000, 3050-OLV, 5100HD, 5100P | Moisture analysers | Water content in natural gas and process gases; the 5100 models use TDLAS |
| 241CE II, Chanscope II / Model 13 | Dew point analysers and testers | Hydrocarbon and water dew point of natural gas |
| WDG 1200/1210, WDG-V, TM2000 | Thermox oxygen analysers | Combustion control on heaters and boilers, and trace oxygen |
| SPOT+, Cyclops L | Land pyrometers | Non-contact temperature of furnaces, kilns, tubes and hot metal |
| 120HD, Ranarex, Drexelbrook RCT-1210 | Portable analysers and level | Hydrogen purity in generators, gas specific gravity, RF level measurement |
Most of these analysers work on light absorption. UV analysers such as the 933 and 9900 measure H2S and SO2 by their absorption bands, and tail gas analysers use this to keep the H2S to SO2 ratio near 2:1 for the best Claus conversion. TDLAS moisture analysers use a tuned laser on a single water line, so they respond fast and do not suffer from the glycol and methanol contamination that affects sensor-based analysers.
Where AMETEK instruments are used
In Oman and the GCC, AMETEK analysers run on gas processing and sulfur recovery units, gas pipelines and custody points, refinery heaters and boilers, power station generators and steel and cement furnaces.
Ordering AMETEK products: what we need
Send the model and the complete part or sales order number from the nameplate. For a new analyser, send the gas composition, the component and range to be measured, the sample pressure and temperature, and the hazardous area classification. For spare parts, send the part number and the analyser serial number.
Facts checked against AMETEK company history, October 2026.
Browse AMETEK products by category: Gas Analyzer Accessories, Gas Analyzer Systems, Liquid Analytical Accessories, Level Transmitter.
FAQ
Questions about the AMETEK 700-0002-024 Drexelbrook 3/4 in PTFE
Answers from our engineering team on installation, compatibility and integration.
01What temperature can 700-0002-024 handle?
The Universal IV table gives 700-0002-024 a maximum of 450 F at 500 psi and 1000 psi at 100 F.
02What is the diameter and insulation of 700-0002-024?
700-0002-024 is a 3/4 inch OD rod with PTFE insulation, carrying SE code 311.
03Is 700-0002-024 suitable for coating liquids?
No. The manufacturer lists it for non-coating liquids and interface; heavier coating services point to the FEP or PVDF elements instead.
04Can I mount the electronics remotely with 700-0002-024?
Yes, the Universal IV supports remote configuration with up to 100 ft of cable, helpful when the vessel is hot.
05What details are needed for an RFQ on 700-0002-024?
Quote the part number 700-0002-024 with quantity, insertion length, process connection and electronics type.


















Reviews