Brand: Beamex
Beamex 8003187 PGHH Vent Valve Spare Assembly
Description
Beamex 8003187 PGHH vent valve: what the assembly is
Beamex 8003187 is the replacement vent valve assembly for the Beamex PGHH hydraulic calibration pump. It arrives as a preassembled vent valve mechanism with its handwheel already fitted, and the set also carries a bonded seal and a 6 mm stainless steel release valve ball. The maker describes it as an assembly that can simply be swapped into a PGHH pump when the original has broken.
On the pump the vent valve is item 4 in the overview drawing of the PGHH manual, sitting beside the fine adjust and the reservoir filling plug. It is the control that dumps system pressure back into the reservoir, so a worn or cracked unit shows up quickly as an inability to hold or to release pressure cleanly. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Contents of the set and how it works
- Preassembled vent valve mechanism with handwheel.
- One bonded seal for the valve seat.
- One 6 mm stainless steel release valve ball.
The PGHH manual lists the seal at this position as a 1/8 inch bonded seal (usit) for the vent valve, and it names the release valve tappet inside the top of the pump as the part the valve acts on. Turning the handwheel clockwise closes the valve for pressure build-up; turning it counterclockwise opens the release path. Because 8003187 is sold as one assembly, you do not have to rebuild the seat from loose parts.
Technical data for the host pump of 8003187
| Item | Detail |
|---|---|
| Part number | 8003187 |
| Product name | PGHH vent valve |
| Fits | Beamex PGHH hydraulic calibration pump |
| Pump pressure range | 0 to 700 bar / 0 to 10,000 psi |
| Side pressure port | G1/4 inch female with pre-installed Bx 1215 male fitting for the 630 bar hose |
| Top pressure port | G1/4 inch B female for an EXT60 to EXT1000 module, closed with a G1/4 inch male plug |
| Pressure media | Low viscosity mineral hydraulic oil (RENOLIN MR 5 VG 22) or distilled water |
| Reservoir | 200 ml / 12.2 cubic inch acrylic, not to be pressurized |
| Pump weight | 1.3 kg / 2.87 lb |
| Pump size (H x W x D) | 265 x 160 x 120 mm |
| Operating temperature | 0 to 50 degrees C |
| Storage temperature | minus 10 to 50 degrees C |
| Tightening torque | 25 Nm for connections, drain screw maximum 15 Nm |
Where it matters: field use in Oman and the GCC
A hydraulic pump of this class is used where transmitters and gauges are checked at several hundred bar: wellhead and flowline instrumentation in oil and gas, high-pressure steam and feedwater gauges in power and desalination plants, and hydraulic test circuits in heavy manufacturing. In those jobs the vent valve is operated dozens of times per shift, so it is the first moving part on the pump to show wear.
Keeping a spare assembly in the instrument workshop avoids sending a whole PGHH away for a small fault, which matters when a calibration contract has a fixed turnaround. Shipping glass and liquid-filled pumps to a service centre also carries the rule that the reservoir must be emptied first.
How 8003187 differs from other PGHH service parts
The PGHH family has several separately ordered spare parts, and each addresses a different failure. 8003187 deals only with the venting function. The 8003192 pressure cylinder is a much larger repair for a leaking pump after the cylinder seals have been replaced, the 8003194 reservoir kit replaces the 200 ml acrylic reservoir with two 67 x 3 mm O-rings, and the 8003199 stroke selector kit replaces the prime and high stroke knob and shaft.
If the pump leaks at the handwheel or you cannot fully relieve pressure, 8003187 is the matching part. If pressure falls steadily even though the vent valve is closed, check the seals listed in the manual before ordering anything.
Fitting and commissioning notes
The maker supplies a step-by-step video for this exchange, and the manual states that spare parts are intended for repair by the user or by the maker’s service. Before opening the pump, depressurize it, empty the reservoir and keep it upright. Coat O-rings with a very small amount of silicone grease and tighten connections to 25 Nm.
After fitting 8003187, perform the manual’s leak test. Fill the reservoir, close the vent valve, run the pump to the maximum pressure of the connected module, wait five minutes, return to the set point with the fine adjust and wait two minutes more. At a 700 bar set point the pressure should fall by less than 5 bar in that final period; a larger drop means the pump is still leaking.
Operating cautions that protect the valve
Two rules in the manual are written specifically for this part. First, do not overtighten the vent valve when closing it: the release valve tappet or the top of the pump may be damaged, or the whole valve may break. Second, never unscrew the valve completely, because the tappet inside the pump can fall out and be lost.
For normal pressure release the manual names the fine adjust as the main tool, with the vent valve as an option that needs care to avoid pressure shocks to the measuring system. To dump all pressure, open the vent valve counterclockwise, squeeze the handles fully and only then return the stroke selector to the prime position.
Maintenance and ordering notes
Use only the low viscosity mineral oil or distilled water named by the maker; other fluids such as synthetic hydraulic oil can damage seals and the reservoir. If distilled water is used, empty and dry the pump after each session. Check that the pressure compensation screw is clear, since a blocked screw can break the reservoir.
When you request 8003187, quote the pump serial number and the symptom so the correct kit is confirmed. Related parts that often accompany a vent valve repair are the bonded seal packs and the PGHH full service kit, which should be checked against your pump before ordering.
Documents and quotation
The PGHH user manual is supplied as the datasheet for Beamex 8003187. To receive a quotation, send the part number 8003187, the quantity required and the PGHH serial number in your RFQ to Seven Star LLC. Availability and lead time are confirmed per request.
Other Models in the Pghh Spares Range
Seven Star LLC supplies models from the Pghh Spares range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Beamex 8003187 PGHH Vent Valve Spare Assembly | Process, Pressure & Temperature Calibrators | You are viewing this model |
| Beamex 8003192 PGHH Pressure Cylinder Service Kit | Process, Pressure & Temperature Calibrators | View details |
| Beamex 8003194 PGHH Reservoir Replacement Kit | Process, Pressure & Temperature Calibrators | View details |
| Beamex 8003199 PGHH Stroke Selector Service Kit | Process, Pressure & Temperature Calibrators | View details |
Datasheets & Documents
- Datasheet Beamex 8003187 PGHH Vent Valve Spare Assembly Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Beamex is a Finnish maker of calibration equipment and software for process instruments. Four calibration technicians founded the company in 1975 because they could not find the equipment they wanted; their first product was a voltage and current simulator, and the first factory opened in 1977. Beamex is headquartered in Pietarsaari (Jakobstad), Finland, and supplies process industries in more than 100 countries.
Seven Star LLC is an independent supplier listing Beamex documenting calibrators, temperature dry blocks, pressure controllers, calibration pumps and pressure modules for buyers in Oman and the GCC. Equipment is quoted against the model and the pressure or temperature ranges required.
Beamex company profile
| Origin | Founded in 1975 in Finland by four calibration technicians; first factory 1977 |
|---|---|
| Headquarters | Pietarsaari (Jakobstad), Finland; ISO 9001 certified since 1992 |
| Product families | MC series multifunction calibrators, temperature dry blocks, automatic and hand pressure generators, external pressure modules, CMX and LOGiCAL calibration software |
| Typical duty | Field and workshop calibration of pressure, temperature and electrical signal instruments, including HART and fieldbus transmitters |
Milestones
- 1975: Four calibration technicians found the company in Finland.
- 1977: The first factory opens.
- 1992: ISO 9001 certification.
Beamex calibrators and accessories
| Model | Type | Typical use |
|---|---|---|
| MC6 | Advanced field calibrator and communicator | Pressure, temperature and electrical calibration with a built-in HART, FOUNDATION Fieldbus and PROFIBUS PA communicator, documented results |
| MC6-Ex | Intrinsically safe field calibrator | Calibration inside Zone 0 and Zone 1 hazardous areas without a hot work permit |
| MC6-T | Temperature calibrator with integrated dry block | Temperature sensors and transmitters, with multifunction electrical and pressure measurement |
| MC4, MC2 | Documenting and hand-held process calibrators | Routine loop, transmitter and switch checks in the field |
| FB, MB | Field and metrology temperature dry blocks | FB for field calibration; MB for higher-accuracy workshop and laboratory work |
| ePG, POC8 | Electric pressure pump and automatic pressure controller | Automated pressure calibration; POC8 for workshop calibration benches |
| PGC, PGM, PGL, PGPH, PGHH | Hand pressure pumps | Pressure and vacuum generation in the field, from low pressure (PGL, ±400 mbar) to hydraulic 700 bar (PGHH) |
| EXT modules | External pressure modules | Extending MC calibrators to additional ranges, 70 kPa to 100 MPa |
Where Beamex equipment is used
Instrument workshops and maintenance teams in oil and gas, refining, petrochemicals, power, water and pharmaceuticals use Beamex calibrators to verify transmitters, switches, gauges and temperature sensors. Documenting calibrators send results to calibration software, which keeps the audit trail required by quality systems and custody transfer metering procedures. Intrinsically safe models are used for in-situ calibration in classified areas.
Ordering Beamex equipment: what we need
State the model and the options you need: internal and external pressure ranges, temperature range, communication protocols (HART, FOUNDATION Fieldbus, PROFIBUS PA), Ex approval, and whether an accredited calibration certificate is required. For spare modules and pumps send the serial number of the calibrator they will be used with, so compatibility can be confirmed.
Facts checked against Beamex company history and product information, October 2026.
Browse Beamex products by category: Portable Test & Measurement, Temperature Instrumentation.
FAQ
Questions about the Beamex 8003187 PGHH Vent Valve Spare Assembly
Answers from our engineering team on installation, compatibility and integration.
01What does Beamex 8003187 contain?
It contains a preassembled PGHH vent valve mechanism with handwheel, a bonded seal and a 6 mm stainless steel release valve ball.
02Which pump uses the 8003187 vent valve?
It is made for the Beamex PGHH hydraulic calibration pump rated 0 to 700 bar, where the vent valve is item 4 in the manual's overview.
03Can I unscrew the vent valve completely?
No. The manual cautions that the release valve tappet inside the pump may fall out and be lost if the valve is fully unscrewed.
04How do I test the pump after replacing the vent valve?
Run the manual's leak test: at a 700 bar set point the pressure should fall by less than 5 bar in the final two minutes after the five-minute settling period.
05Does 8003187 replace the reservoir or the pressure cylinder?
No. It only replaces the vent valve. The reservoir, pressure cylinder and stroke selector have their own separate kits.