Brand: Endress+Hauser (E & H)
Endress+Hauser FMR532 Micropilot S Planar Stilling Well Radar
Description
Endress+Hauser FMR532: the stilling-well specialist for precise tank gauging
Endress+Hauser FMR532 is the planar-antenna version of the Micropilot S custody-transfer radar and the one made solely for stilling wells. Its datasheet TI01122F states a measuring range up to 38 m (125 ft), a typical free-application accuracy of plus or minus 0.8 mm, NMi and PTB approvals and compliance with OIML R85 and API 3.1B. A planar antenna can be mounted directly onto the flange of a stilling well, including tapered ones.
Stilling wells shelter the radar beam from foam, turbulence and vapor layers, and they are standard on floating-roof tanks and on tanks with volatile products, so FMR532 turns up wherever those tank types are gauged.
Radar in a stilling well behaves differently from radar in open space. The pipe guides the wave, so the signal loses little energy and the return from the surface is strong even on low-permittivity hydrocarbons. The planar antenna produces a circular-mode radar pattern, which the datasheet describes as a must for high-accuracy applications on stilling wells; ordinary horn antennas excite other modes that travel at slightly different speeds and degrade the result.
Key figures for FMR532
| Parameter | Value |
|---|---|
| Antenna | Planar antenna, for stilling well applications only |
| Range | Up to 38 m; with custody-transfer NMi approval up to 25 m |
| Accuracy | Absolute better than plus or minus 1 mm; typical plus or minus 0.8 mm |
| Approvals | NMi, PTB, OIML R85, API 3.1B |
| Inventory Control version | 3 mm accuracy, order code version R |
| Stilling well diameter | Recommended from DN 150 |
| Maximum gap antenna to well wall | 5 mm |
| Maximum gap at joints or valves | 1 mm |
| Hole diameter in the well | Up to 1/7 of well diameter, never above 30 mm |
| Power consumption | Maximum 330 mW at 16 V; 500 mW at 24 V |
| Output | 4 to 20 mA with HART, four-wire, 24 VDC intrinsically safe; Tank Side Monitor NRF590 |
Why the stilling well rules matter for FMR532
The datasheet gives a precise list of stilling-well requirements because the circular-mode wave pattern of the planar antenna depends on a clean pipe. The inside must be smooth, made of extruded or parallel-welded steel; rectangular diameter increases must be avoided; weld seams should be smooth and in line with the slots; holes are preferred to slots; the hole diameter can be a seventh of the well diameter but never more than 30 mm; the gap between antenna and well wall must not exceed 5 mm, and gaps at intersections or valves must not exceed 1 mm. Welding through the pipe wall is forbidden, since the resulting unevenness produces strong interference echoes and promotes build-up.
Typical applications of FMR532 in Oman and the GCC
Floating-roof crude and product tanks, pressurised or refrigerated storage with a gauge well, and chemical tanks where vapors or foam would disturb a free-space beam. Terminals use FMR532 together with the Tank Side Monitor NRF590 and inventory software for custody transfer and loss control.
The Tank Side Monitor can communicate with up to six HART devices on the intrinsically safe bus, and it adds spot or average temperature, water-level and pressure signals so that the inventory system can compute volume and mass. HART carries the primary value because only the digital signal preserves the millimetre resolution.
Because the instrument sits on an existing gauge well, retrofitting a mechanical servo gauge or float with FMR532 can often reuse the well and the flange, subject to checking the well against the rules above.
How FMR532 differs from FMR530 and FMR533
| Item | FMR532 | FMR530 | FMR533 |
|---|---|---|---|
| Antenna | Planar | Horn | Parabolic |
| Installation | Stilling well only | Free space | Free space |
| Typical accuracy | 0.8 mm | 0.5 mm | 0.5 mm |
| Range | Up to 38 m | Up to 25 m | Up to 40 m |
Installation of FMR532
Ensure the planar axis is vertical to the flange and the antenna fits the well within the 5 mm gap. Where the well has a manual gauging nozzle, use it for verification, and where an extension is needed, use a suitable antenna adapter with at least 0.5 m between the upper end of the well and the extension. Run four-wire screened cable to the NRF590, connect the shield on one side only and set the gauge reference height with care.
Service and verification of FMR532
Compare the radar with a calibrated dip tape at agreed intervals, inspect the stilling well for deposits and corrosion, and keep the calibration certificate and seals intact. The instrument self-monitors compliance with OIML R85 and reports if the accuracy cannot be maintained. A deteriorating stilling well is the most frequent long-term cause of drift: corrosion, scale and bent pipe sections change how the wave travels. Plan a well inspection at each tank cleaning and record what is found.
After mechanical work, repeat the empty calibration and confirm the gauge reference height with a strapping or a verified dip. The long-term drift of the radar itself is stated in the sheet to be within the specified accuracy, so most deviations found in the field have a mechanical cause.
Ordering notes for FMR532
List well diameter, flange and the approval variant (custody transfer or inventory control). Photograph the old nameplate if the unit replaces an existing gauge. Provide also the tank type, the height of the well and whether it is perforated with holes or slots, because those details decide whether the well meets the requirements in the datasheet.
If the well does not meet the rules, the sheet advises that modifications are possible, for example smoothing weld seams or adding an adapter, but this must be done under the tank owner’s procedures and, for custody transfer, agreed with the weights-and-measures authority.
Documents and quotation
Datasheet: Technical Information TI01122F. Send the part number, well diameter and quantity through the RFQ form. Seven Star LLC is an independent supplier serving Oman and the GCC and is not affiliated with the manufacturer.
Other Models in the Micropilot S Range
Seven Star LLC supplies models from the Micropilot S range in Oman and the GCC. Compare the related models below and request a quote for the one that matches your application.
| Model | Category | |
|---|---|---|
| Endress+Hauser FMR530 Micropilot S Custody Transfer Radar | Radar & Guided Wave Radar Level | View details |
| Endress+Hauser FMR532 Micropilot S Planar Stilling Well Radar | Radar & Guided Wave Radar Level | You are viewing this model |
Datasheets & Documents
- Datasheet Endress+Hauser FMR532 Micropilot S Planar Stilling Well Radar Datasheet Download
Reviews (0)
How would you rate this product? Cancel reply
About brand
Endress+Hauser makes process measurement instruments for flow, level, pressure, temperature and liquid analysis. Georg H. Endress and Ludwig Hauser started the business in Lörrach, Germany, on 1 February 1953, first selling level meters, and the Endress+Hauser name has been used since 1957. The group is headquartered in Reinach, Switzerland, and has been wholly owned by the Endress family since 1975.
Seven Star LLC is an independent supplier listing Endress+Hauser flowmeters, level and pressure transmitters, temperature assemblies and liquid analysis products for buyers in Oman and the GCC. Instruments are matched from the full order code on the nameplate.
Endress+Hauser company profile
| Origin | Founded in Lörrach, Germany, on 1 February 1953 by the Swiss engineer Georg H. Endress and Ludwig Hauser |
|---|---|
| Headquarters | Endress+Hauser AG, Reinach (Basel-Landschaft), Switzerland |
| Ownership | Family owned; the Endress family has been the sole shareholder since 1975, and a family charter commits the company to stay family owned |
| Size | About 16,500 employees and sales of about EUR 3.7 billion (2023, as reported by the company) |
| Product families | Proline flowmeters, Micropilot and Levelflex radar, Liquiphant switches, Cerabar and Deltabar pressure, iTEMP and iTHERM temperature, Liquiline and Memosens liquid analysis |
Milestones
- 1953: Georg H. Endress and Ludwig Hauser start the business in Lörrach on 1 February, first selling level meters.
- 1957: The Endress+Hauser name comes into use.
- 1975: The Endress family becomes sole shareholder.
- 2023: About 16,500 employees and sales of about EUR 3.7 billion, as reported by the company.
Endress+Hauser product lines
| Line | Measuring principle | Typical use |
|---|---|---|
| Promass F 300, Promass 80F, 83F/84F | Coriolis mass flow | Direct mass flow and density of liquids and gases, hydrocarbon transfer and chemical dosing |
| Promag P 300, P 500, H 300, W 400, W 10, 50P | Electromagnetic flow | Water, wastewater, slurries and other conductive liquids |
| Prowirl F 200, 72F | Vortex flow | Steam, gas and low-viscosity liquids |
| Prosonic Flow 92F, t-mass 65F | Ultrasonic and thermal mass flow | Water lines; compressed air and industrial gases |
| Micropilot FMR62, FMR67, FMR60, FMR10B, FMR20, FMR50, FMR52 | Free-space radar level, 80 GHz and 26 GHz | Tanks, process vessels, silos and open water channels |
| Levelflex FMP51, FMP50, FMP54, FMP55 | Guided wave radar level | Level and interface in vessels, separators and bypass chambers |
| Liquiphant FTL51, Prosonic S FMU90 | Vibronic point level; ultrasonic level | High and low level alarms, pump protection, open channel flow |
| Cerabar PMC71B, PMP51B, PMP71, Deltabar PMD78B, PMD75 | Pressure and differential pressure | Process pressure, hydrostatic level and DP flow |
| iTEMP TMT82, TMT162, iTHERM TM101, TR66, TR10 | Temperature transmitters and thermometers | RTD and thermocouple points with thermowells |
| Liquiline CM444, CM442, Memosens CPS11E, Stamolys reagents | Liquid analysis | pH, ORP, conductivity, dissolved oxygen and nutrient analysis in water treatment and process |
Where Endress+Hauser instruments are used
In Oman and the GCC, Endress+Hauser instruments are common in oil and gas production and processing, refineries and petrochemicals, desalination and water networks, wastewater treatment, power plants and food and beverage plants. Coriolis meters measure hydrocarbon and chemical flows, electromagnetic meters cover water and wastewater, radar transmitters handle tank and silo level, and Liquiline analysers monitor water quality. Proline 300 and 500 flowmeters include Heartbeat Technology for in-situ verification, which reduces the need to remove a meter for checks.
Ordering Endress+Hauser instruments: what we need
The order code on the nameplate (for example PMP71-1QA1S11RDADU) defines every option: measuring range, process connection, materials, output, approvals and display. Send it with the serial number; Endress+Hauser can retrieve the original configuration from the serial number. For a new instrument add the medium, operating and design pressure and temperature, range, line size or tank geometry, process connection, wetted materials, output or protocol (4-20 mA HART, PROFIBUS, FOUNDATION Fieldbus, Modbus) and the hazardous-area approval required. Older models such as Promass 80/83 or Micropilot M are replaced by current Proline or 80 GHz Micropilot devices.
Facts checked against Endress+Hauser company history and product information, October 2026.
Browse Endress+Hauser products by category: Flowmeters, Level Transmitter, Pressure Instrumentation, Temperature, Liquid Analysis Sensors, Liquid Analytical Systems.
FAQ
Questions about the Endress+Hauser FMR532 Micropilot S Planar Stilling
Answers from our engineering team on installation, compatibility and integration.
01What antenna does Endress+Hauser FMR532 have?
A planar antenna intended exclusively for stilling well applications, which can be mounted even on tapered wells.
02How far does FMR532 measure?
Up to 38 m (125 ft), and up to 25 m (82 ft) with custody-transfer NMi approval.
03What stilling well diameter suits FMR532?
The datasheet recommends FMR532 for stilling wells with diameters from DN 150.
04How accurate is FMR532?
Absolute accuracy better than plus or minus 1 mm, typically plus or minus 0.8 mm in application.
05What gaps are allowed in the stilling well?
Maximum 5 mm between the antenna and the well wall and no more than 1 mm at pipe joints or valves.


















Reviews
There are no reviews yet.